Gi-Beum Kim

Gi-Beum Kim


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
HJHye-Yeon Jang
Hye-Yeon Jang
GKGi-Beum Kim
Gi-Beum Kim
JKJeong-Mi Kim
Jeong-Mi Kim
SKSang Yull Kang
Sang Yull Kang
HYHyun Jo Youn
Hyun Jo Youn
JKJong-Suk Kim
Jong-Suk Kim
Fisetin is a flavonoid found in plants and has been reported to be effective in various human diseases. However, the effective mechanisms of ultraviolet-A (UVA)-mediated skin damage are not yet clear. In this study, we investigated the protective mechanisms of fisetin regarding UVA-induced human dermal fibroblasts (HDFs) and human epidermal keratinocytes (HEKs) damages. Fisetin showed a cytoprotective effect against UVA irradiation and suppressed matrix metalloproteinases (MMPs), MMP-1, and MMP-3 expression. In addition, fisetin was rescued, which decreased mRNA levels of pro-inflammatory cytokines, reactive oxygen species production, and the downregulation of MAPK/AP-1 related protein and NADPH oxidase (NOX) mRNA levels. Furthermore, UVA-induced MMP-1 and MMP-3 were effectively inhibited by siRNAs to NOX 1 to 5 in HDFs and HEKs. These results indicate that fisetin suppresses UVA-induced damage through the NOX/ROS/MAPK pathway in HDFs and HEKs.

18 February 2022 in Molecules
Verified
Journal Article
Open access
PDF file
GKGi-Beum Kim
Gi-Beum Kim
KPKwang-Hyun Park
Kwang-Hyun Park
SKSeong-Jong Kim
Seong-Jong Kim
The purpose of this study was to identify the characteristics of blood flow in aortic coarctation based on stenotic shape structure, stenosis rate, and the distribution of the wall load delivered into the blood vessels and to predict the impact on aneurysm formation and rupture of blood vessels by using a computational fluid dynamics modeling method. It was applied on the blood flow in abdominal aortic blood vessels in which stenosis occurred by using the commercial finite element software ADINA on fluid-solid interactions. The results of modeling, with an increasing stenosis rate and Reynolds number, showed the pressure drop was increased and the velocity was greatly changed. When the stenosis rate was the same, the pressure drop and the velocity change were larger in the stenosis with a symmetric structure than in the stenosis with an asymmetric one. Maximal changes in wall shear stress were observed in the area before stenosis and minimal changes were shown in stenosis areas. The minimal shear stress occurred at different locations depending on the stenosis shape models. With an increasing stenosis rate and Reynolds number, the maximal wall shear stress was increased and the minimal wall shear stress was decreased. Through such studies, it is thought that the characteristics of blood flow in the abdominal aorta where a stenosis is formed will be helpful in understanding the mechanism of growth of atherosclerosis and the occurrence and rupture of the abdominal aortic flow.

17 November 2019 in Genes & Genomics
Verified
Journal Article
Closed access
PDF file
KPKwang-Hyun Park
Kwang-Hyun Park
ECEun-Yong Chung
Eun-Yong Chung
YCYu-Na Choi
Yu-Na Choi
HJHye-Yeon Jang
Hye-Yeon Jang
JKJong-suk Kim
Jong-suk Kim
GKGi-Beum Kim
Gi-Beum Kim

18 April 2023 in Molecules
Verified
Journal Article
Open access
PDF file
GKGi-Beum Kim
Gi-Beum Kim
KSKwansung Seo
Kwansung Seo
JYJong-Ung Youn
Jong-Ung Youn
IKIl Keun Kwon
Il Keun Kwon
JPJinny Park
Jinny Park
JKJong-Suk Kim
Jong-Suk Kim
In this study, we aimed to develop natural and/or functional materials with antioxidant and anti-inflammatory effects. We obtained extracts from natural plants through an oil and hot-water extraction process and prepared an extract composite of an effective unsaturated fatty acid complex (EUFOC). Furthermore, the antioxidant effect of the extract complex was evaluated, and the anti-inflammatory effect was explored by assessing its inhibitory effect on nitric oxide production through its HA-promoting effect. We conducted a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide assay to evaluate the cell viability of the EUFOC, and the results showed that EUFOC was not cytotoxic at the test concentrations. In addition, it showed no endogenous cytotoxicity in HaCaT (human keratinocyte) cells. The EUFOC showed excellent 1,1-diphenyl-2-picrylhydrazyl- and superoxide-scavenging abilities. Moreover, it exerted an inhibitory effect on NO production at concentrations that did not inhibit cell viability. The secretion of all the cytokines was increased by lipopolysaccharide (LPS) treatment; however, this was inhibited by the EUFOC in a concentration-dependent manner. In addition, hyaluronic acid content was markedly increased by the EUFOC in a dose-dependent manner. These results suggest that the EUFOC has excellent anti-inflammatory and antioxidant properties, and hence, it can be used as a functional material in various fields.

9 March 2022 in Molecules
Verified
Journal Article
Open access
PDF file
GKGi-Beum Kim
Gi-Beum Kim
YPYoung-Ran Park
Young-Ran Park
SKSeong-Jong Kim
Seong-Jong Kim
KPKwang-Hyun Park
Kwang-Hyun Park
In this paper, we studied the effects of the intersection angle between the inlet channels on the droplet diameter using a COMSOL Multiphysics® simulation. We employed the level-set method to study the droplet generation process inside a microfluidic flow device. A flow-focusing geometry was integrated into a microfluidics device and used to study droplet formation in liquid–liquid systems. Droplets formed by this flow-focusing technique are typically smaller than the upstream capillary tube and vary in size with the flow rates. Different intersection angles were modeled with a fixed width of continuous and dispersed channels, orifices, and expansion channels. Numerical simulations were performed using the incompressible Navier–Stokes equations for single-phase flow in various flow-focusing geometries. As a result of modeling, when the dispersed flow rate and the continuous flow rate were increased, the flow of the continuous flow fluid interfered with the flow of the dispersed flow fluid, which resulted in a decrease in the droplet diameter. Variations in the droplet diameter can be used to change the intersection angle and fluid flow rate. In addition, it was predicted that the smallest diameter droplet would be generated when the intersection angle was 90°.

23 December 2024 in Med Discoveries
Verified
Journal Article
Open access
GKGi-Beum Kim
Gi-Beum Kim
Aconiti tuber is used after its toxicity is reduced by using various processing methods, Suchi Processing. The processing to use medicine of plants, animals, minerals in Korean and Chinese medicine.