The dynamics, heating rates, gaseous emissions and energetics of thermally-induced thermal runaway propagation in dense arrays consisting of 12–15 fully charged 18650 lithium ion cells have been quantified to determine the effectiveness of several passive mitigation strategies. These strategies include implementing 5 mm gaps between select rows and columns in the array, and inserting physical barriers, such as double-layer stainless steel, intumescent material or ceramic fiber board into the gaps. All experiments were performed in a wind tunnel facility that allows tracking of thermal runaway propagation through the arrays with well-defined experimental conditions. None of the tested mitigation strategies completely prevented propagation. However, the physical barriers were found to be effective in slowing the propagation speed. Among the barriers, ceramic fiber board was found to be the most effective slowing down the propagation by more than a factor of 30. Additionally, contributions of different heat transfer processes driving the propagation were quantified. In air experiments on the arrays without gaps or barriers, 50% of heat flow to downstream (non-failed) cells was associated with flaming combustion of ejected battery materials, 20% was associated with direct cell-to-cell conduction and the rest was associated with convective and radiative heat transfer between cells.
25 April 2019 in Transportation Research Record: Journal of the Transportation Research Board
Lithium ion batteries are increasingly used in electrical energy storage systems despite their thermal and chemical hazards on failure. These hazards are magnified when multiple cells are combined together in a pack because of the risk of cascading failure. An experimental setup was utilized to investigate the dynamics, gaseous emissions, and energetics associated with thermal failure of cylindrical 18650 form factor, 2600 mAh, lithium cobalt oxide cathode cell arrays in an inert atmosphere. Cell state of charge (SOC) and arrangement were altered to investigate mitigation strategies and provide recommendations for safer battery pack design, transportation, and storage. Complete failure propagation was not prevented in any test, but decreasing to 50% SOC did result in propagation speeds 8.5 times slower than at 100% SOC. Introducing a 5 mm gap between cell rows also slowed propagation somewhat, but to a lesser degree than lowering SOC. Maximum temperatures, hazardous gas yields, and chemical heat generation were all reduced for cells at 50% SOC compared with 100% SOC, but introducing 5 mm gaps had little impact on these quantities. Limiting cells to 50% SOC was by far the most effective mitigation strategy tested, but no strategy was able to eliminate the failure propagation risk. Installing battery packs in inert environments, limiting SOC, and instituting gaps between certain cells can all be effective strategies to lessen the severity of cascading failure, but none of these strategies are individually sufficient for safe transportation and storage of battery packs.