Shigeki Kubota

Dr. Shigeki Kubota

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2018 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
SKShigeki Kubota
Shigeki Kubota
TATetsuya Abe
Tetsuya Abe
HKHideki Kadone
Hideki Kadone
YSYukiyo Shimizu
Yukiyo Shimizu
TFToru Funayama
Toru Funayama
MYMasashi Yamazaki
Masashi Yamazaki
Context/Objective: The hybrid assistive limb (HAL) is a wearable exoskeleton robot that assists walking and lower limb movements via real-time actuator control. Our aim was to clarify the safety and feasibility of using the HAL robotic suit for rehabilitation in patients with severe thoracic myelopathy due to ossification of the posterior longitudinal ligament (T-OPLL). Design: Uncontrolled case series; pre- and post-intervention measurement. Setting: In-patient rehabilitation unit. Intervention: HAL training was provided in 60-minuts session, 2–3 sessions per week, for a total of 10 sessions. HAL training was initiated on average 27.5 days post-surgery. Patients: Eight patients (four males and four females; mean age, 60.9 ± 10.2 years) with severe myelopathy, who had undergone posterior decompression with instrumented fusion, were enrolled. Outcome Measures: Gait speed, step length and cadence were measured along a 10-m walkway every session. The American Spinal Injury Association (ASIA) motor score (lower extremities) and Walking Index for Spinal Cord Injury (WISCI) II were also evaluated at baseline and after 10 sessions. The Japanese Orthopaedic Association (JOA) score was calculated over time after surgery. Results: All participants completed the 10 training sessions, with no serious adverse effect noted. Gait speed, step length and cadence improved over time. Both the WISCI-II and ASIA motor (lower extremities) scores improved from baseline after 10 sessions. The JOA score improved over time post-surgery. Conclusion: HAL training can be feasibly initiated in the early postoperative period, without severe adverse events in patients, with T-OPLL-related severe gait disturbance.

2 February 2018 in Journal of Clinical Neuroscience
Verified
Journal Article
Closed access
PDF file
SKShigeki Kubota
Shigeki Kubota
TATetsuya Abe
Tetsuya Abe
MKMasao Koda
Masao Koda
HKHideki Kadone
Hideki Kadone
YSYukiyo Shimizu
Yukiyo Shimizu
MYMasashi Yamazaki
Masashi Yamazaki

7 March 2022 in Medicina
Verified
Journal Article
Open access
PDF file
SKShigeki Kubota
Shigeki Kubota
HKHideki Kadone
Hideki Kadone
YSYukiyo Shimizu
Yukiyo Shimizu
MKMasao Koda
Masao Koda
HNHiroshi Noguchi
Hiroshi Noguchi
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Foot and ankle disabilities (foot drop) due to common peroneal nerve palsy and stroke negatively affect patients’ ambulation and activities of daily living. We developed a novel robotics ankle hybrid assistive limb (HAL) for patients with foot drop due to common peroneal nerve palsy or stroke. The ankle HAL is a wearable exoskeleton-type robot that is used to train plantar and dorsiflexion and for voluntary assistive training of the ankle joint of patients with palsy using an actuator, which is placed on the lateral side of the ankle joint and detects bioelectrical signals from the tibialis anterior (TA) and gastrocnemius muscles. Voluntary ankle dorsiflexion training using the new ankle HAL was implemented in a patient with foot drop due to peroneal nerve palsy after lumbar surgery. The time required for ankle HAL training (from wearing to the end of training) was approximately 30 min per session. The muscle activities of the TA on the right were lower than those on the left before and after ankle HAL training. The electromyographic wave of muscle activities of the TA on the right was slightly clearer than that before ankle HAL training in the resting position immediately after ankle dorsiflexion. Voluntary ankle dorsiflexion training using the novel robotics ankle HAL was safe and had no adverse effect in a patient with foot drop due to peroneal nerve palsy.

20 April 2017 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
SKShigeki Kubota
Shigeki Kubota
TATetsuya Abe
Tetsuya Abe
HKHideki Kadone
Hideki Kadone
KFKengo Fujii
Kengo Fujii
YSYukiyo Shimizu
Yukiyo Shimizu
MYMasashi Yamazaki
Masashi Yamazaki
Context: The hybrid assistive limb (HAL) (the wearable robot) can assist kinesis during voluntary control of hip and knee joint motion by detecting the wearer's bioelectric signals on the surface of their skin. The purpose of this study was to report on walking ability following the wearable robot treatment in a patient with chronic myelopathy after surgery for cervical ossification of the posterior longitudinal ligament (OPLL). Findings: The patient was a 66-year-old woman with cervical OPLL who was able to ambulate independently with the aid of bilateral crutches. The wearable robot treatment was received once every 2 weeks for ten sessions beginning approximately 14 years after surgery. Improvements were observed in gait speed (BL 22.5; post 46.7 m/min), step length (BL 0.36; post 0.57 m), and cadence (BL 61.9; post 81.6 m/min) based on a 10-m walk test and a 2-minute walk test (BL 63.4; post 103.7 m) assessing total walking distance. The improvements in walking ability were maintained after the wearable robot treatment for 6 months. Conclusion: We report the functional recovery in the walking ability of a patient with chronic cervical myelopathy following the wearable robot treatment, suggesting that as a rehabilitation tool, the wearable robot has the potential to effectively improve functional ambulation in chronic cervical myelopathy patients whose walking ability has plateaued, even many years after surgery.

5 August 2017 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
TYTomokazu Yoshioka
Tomokazu Yoshioka
SKShigeki Kubota
Shigeki Kubota
HSHisashi Sugaya
Hisashi Sugaya
KHKojiro Hyodo
Kojiro Hyodo
KOKaishi Ogawa
Kaishi Ogawa
Masashi YamazakiMasashi Yamazaki
Masashi Yamazaki
Maintenance or restoration of a good range of motion of the knee is one of the most important outcomes following knee surgery. According to previous studies, opening wedge high tibial osteotomy enables better recovery of range of motion in knee flexion than that achievable after total knee arthroplasty or unicompartmental knee arthroplasty. However, few reports provide a detailed description of the postoperative recovery of knee extension range of motion after opening wedge high tibial osteotomy. We describe our experience with a knee extension training program using a single-joint hybrid assistive limb device (HAL-SJ; Cyberdyne Inc., Tsukuba, Japan) during the acute recovery phase after opening wedge high tibial osteotomy. The HAL-SJ is a wearable robotic device that facilitates voluntary control of knee joint motion. A 67-year-old Japanese woman who underwent opening wedge high tibial osteotomy for spontaneous osteonecrosis of the left medial femoral condyle received HAL-SJ-based knee extension training postoperatively. Our experience with this patient revealed that knee extension training with the HAL-SJ during the acute phase following opening wedge high tibial osteotomy is feasible. Furthermore, the patient’s knee extension range of motion improved to values similar to those seen during the preoperative stage, and her flexion range of motion was improved at 3 months after the surgery. HAL-SJ-based knee extension training could be used as a novel post-opening wedge high tibial osteotomy rehabilitation modality. Further exploration of individualized optimal settings of the HAL-SJ is required to improve its safety and efficacy.

10 March 2023 in North American Spine Society Journal (NASSJ)
Verified
Journal Article
Open access
MKMasao Koda
Masao Koda
SKShigeki Kubota
Shigeki Kubota
HKHideki Kadone
Hideki Kadone
KMKousei Miura
Kousei Miura
TFToru Funayama
Toru Funayama
MYMasashi Yamazaki
Masashi Yamazaki
The Hybrid Assistive Limb (HAL) is a rehabilitation device that utilizes the “interactive biofeedback” hypothesis to facilitate the motion of the device according to the user's motion intention and appropriate sensory input evoked by HAL-supported motion. HAL has been studied extensively for its potential to promote walking function in patients with spinal cord lesions, including spinal cord injury. We performed a narrative review of HAL rehabilitation for spinal cord lesions. Several reports have shown the effectiveness of HAL rehabilitation in the recovery of walking ability in patients with gait disturbance caused by compressive myelopathy. Clinical studies have also demonstrated potential mechanisms of action leading to clinical findings, including normalization of cortical excitability, improvement of muscle synergy, attenuation of difficulties in voluntarily initiating joint movement, and gait coordination changes. However, further investigation with more sophisticated study designs is necessary to prove the true efficacy of HAL walking rehabilitation. HAL remains one of the most promising rehabilitation devices for promoting walking function in patients with spinal cord lesions.