Gustavo Vianna Cezar

Mr. Gustavo Vianna Cezar


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2022 in Nature Energy
Verified
Journal Article
Open access
PDF file
SPSiobhan Powell
Siobhan Powell
GCGustavo Vianna Cezar
Gustavo Vianna Cezar
LMLiang Min
Liang Min
IAInês M. L. Azevedo
Inês M. L. Azevedo
RRRam Rajagopal
Ram Rajagopal
Electric vehicles will contribute to emissions reductions in the United States, but their charging may challenge electricity grid operations. We present a data-driven, realistic model of charging demand that captures the diverse charging behaviours of future adopters in the US Western Interconnection. We study charging control and infrastructure build-out as critical factors shaping charging load and evaluate grid impact under rapid electric vehicle adoption with a detailed economic dispatch model of 2035 generation. We find that peak net electricity demand increases by up to 25% with forecast adoption and by 50% in a stress test with full electrification. Locally optimized controls and high home charging can strain the grid. Shifting instead to uncontrolled, daytime charging can reduce storage requirements, excess non-fossil fuel generation, ramping and emissions. Our results urge policymakers to reflect generation-level impacts in utility rates and deploy charging infrastructure that promotes a shift from home to daytime charging.

29 March 2015 in arXiv
Verified
Preprint
Open access
PDF file
GCGustavo Vianna Cezar
Gustavo Vianna Cezar
RRRam Rajagopal
Ram Rajagopal
BZBaosen Zhang
Baosen Zhang
This paper addresses stability issues of DC networks with constant power loads (CPL). Common DC networks, such as automotive electrical systems and DC microgrids, typically have a step-up/down converter connected in one side to the main bus and, on the other, to the load. When load is constant power it can generate destabilizing effects if not proper controlled. This paper shows that converters driving CPLs can make the system unstable, even if they are individually stable, depending on network parameters. We mitigate this problem by means of passive components externally connected to the converter/CPL subsystem. The analysis is verified through simulations. We are able to show that certain converter circuit configurations achieve the so called plug-and-play property, which stabilizes the interconnected system for all network parameters. This property is desirable since it is does not require the knowledge of detailed system topology and parameters, which can be time varying and difficult to obtain. This method also contrasts to existing practices of load augmentation, which can lead to severe efficiency losses.