View All Publications
1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SSSwapna Sreenivasagan
Swapna Sreenivasagan
ASAravind Kumar Subramanian
Aravind Kumar Subramanian
ASAbirami Selvaraj
Abirami Selvaraj
Anand MaryaAnand Marya
Anand Marya
Background. Orthodontists use mini‐implants temporarily as an effective mode of skeletal anchorage devices. The placement of mini‐implants can cause pain and discomfort to the patients. Patients often develop swelling, and the pain could interfere with their daily activities. Practitioners tend to prescribe antibiotics and pain medication for management. Objectives. The main objectives of this study are to evaluate the pain perception and discomfort due to mini‐implant placement experienced by the patient and evaluate the interventions for pain management commonly practiced among orthodontists. Materials and Methods. The study was designed as a questionnaire‐based cross‐sectional study. A total of 271 patients were assessed, for whom 625 mini‐implants (ranging from 1.2 to 2 mm diameter and length 8‐14 mm) were placed. Pain scores were assessed using the VAS and the “Faces” pain rating scale to collect data about discomfort in daily activity and function. Data was collected from 244 patients. A total of 155 orthodontists were questioned regarding the prescription of medications and the interventions for managing pain and adverse effects. Results. Average pain score among female subjects was 16.71 and among men was 13.5. The highest pain scores were recorded for palatal mini‐implants with an average score of 36.29 and the least for interradicular mini‐implants with an average score of 9.02. Among the subjects, 47.9% of them took analgesics, and the most commonly prescribed analgesics were paracetamol (39%). Swelling at the site is where the mini‐implants were placed, and ulceration due to implants were commonly dealt with the excision of the surrounding soft tissue, composite placement, and palliative care with oral analgesic gels. Conclusion. Female subjects had more mini‐implants placed, and female subjects had also given more pain scores than their male counterparts. Palatal mini‐implants caused the highest pain, followed by mini‐implants placed at the infrazygomatic crest and the buccal shelf region. Palatal mini‐implants caused maximum discomfort during speech and eating, followed by the mini‐implant in the buccal shelf and the infrazygomatic crest region that also caused difficulty in yawning and laughing. Infiltration anesthesia was commonly given for the placement of interradicular implants and extra‐alveolar mini‐implants. Paracetamol was the most prescribed by the orthodontists, and more than half the doctors did not regularly prescribe antibiotics.

1 September 2021 in International Orthodontics
Verified
Journal Article
Closed access
SSSwapna Sreenivasagan
Swapna Sreenivasagan
SSSwapna Sreenivasagan
Swapna Sreenivasagan

1 January 2023 in The Journal of Contemporary Dental Practice
Verified
Journal Article
Closed access
ASAravind Kumar Subramanian
Aravind Kumar Subramanian
SSSwapna Sreenivasagan
Swapna Sreenivasagan
KMKarthik Ganesh Mohanraj
Karthik Ganesh Mohanraj
RKRajesh S Kumar
Rajesh S Kumar
To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site. The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals. The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants. Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis. Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, et al. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.


27 June 2023 in International journal of health sciences
Verified
Journal Article
Open access
PDF file
ATAsmidha Thiyagarajan
Asmidha Thiyagarajan
VMVasanth Magesha
Vasanth Magesha
SSSwapna Sreenivasagan
Swapna Sreenivasagan
ASAshok K Sundramoorthy
Ashok K Sundramoorthy
Background: Nickel titanium wires are superior for first alignment because they have exceptional shape memory and super-elasticity. Increased concerns have been raised about the high rate of nickel (Ni) allergy and the growing usage of dental biomaterials that contain Ni. Aim: The aim of the study was to analyze and evaluate the rate of nickel release from different types of orthodontic arch wires. Materials and methods: A set of arch wires of nickel titanium (NiTi), SS and Cu-NiTi were immersed in artificial saliva for three days and analyzed after three days. The amount of Ni ions released from the sample were evaluated using electrochemical techniques such as Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and polarization (Tafel) plot. Results: The EIS and Tafel graph confirmed the s-NiTi, s-CuNiTi showed an excellent corrosion resistance than the s-SS. From all the above measurements, we can conclude that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day. Conclusion: From this study it was concluded that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day, and there was nickel ion release but at a very negligible rate.

14 October 2025 in Journal of Advanced Oral Research
Verified
Journal Article
Closed access
SSSwapna Sreenivasagan
Swapna Sreenivasagan
KRKavitha Ramsundar
Kavitha Ramsundar
Aim: To determine the most favorable site for placing mini-implants within the mandibular buccal shelf (MBS) by evaluating buccal bone width and cortical bone thickness. Background: This review sought to analyze the MBS using cone-beam computed tomography (CBCT) data from diverse populations, including Caucasian, Asian, and South Asian adolescents and adults. Comparisons were made across potential insertion zones buccal to the first and second molars, with specific attention to the mesiobuccal and distobuccal aspects. The primary outcomes were buccal bone width, cortical thickness, and insertion angulation relevant to achieving predictable miniscrew stability. Materials and Methods: Conducted in accordance with PRISMA guidelines, the review protocol was registered on PROSPERO (CRD42021258738). A systematic search of PubMed, Embase, Web of Science, and Cochrane databases, supplemented by hand searching, identified 878 records. Eligible studies included randomized controlled trials and observational designs that reported MBS dimensions for miniscrew placement. Data were extracted on bone width, cortical thickness, and insertion angle. Quantitative synthesis was carried out using R statistical software, and study quality was evaluated with the QUAMAS tool. Results: Eight studies with comparable data were meta-analyzed. Significance was set at 0.05 for comparisons of bone width and cortical thickness. Risk-of-bias assessment identified nine studies as high quality and five as moderate. Findings consistently indicated the distobuccal cusp region of the mandibular second molar as the most favorable insertion site, followed by the mesiobuccal cusp area. Despite methodological differences across included studies, pooled analysis revealed significant differences ( p < .05) among sites, with the second molar region demonstrating superior dimensions for achieving miniscrew stability. Conclusion: The MBS adjacent to the distobuccal cusp of the second molar provides the most advantageous bone morphology for miniscrew placement, offering greater buccal bone width and cortical thickness. This location supports enhanced stability and should be considered the preferred choice for orthodontic anchorage in clinical practice.