We developed an efficient microwave-assisted three-step synthesis of zolpidem and its fluorinated analogues 1–3. The procedure relays on the utilization of easily accessible and inexpensive starting materials. Our protocol shows superior performance in terms of yield and purity of products, compared to conventional heating systems. Notably, the total time needed for reaction accomplishment is significantly lower comparing to oil bath heating systems. Finally, we have performed a detailed study on the preparation of zolpidem tartrate salt I, and we assessed its particle-sizes using a polarizing microscope. Our goal was to select the appropriate method that generates the acceptable particle-size, since the solid-size directly influences solubility in biological fluids and further bioavailability. We believe that the disclosed procedure will help to produce a lab-scale quantity of zolpidem and its fluorinated derivatives 1–3, as well as zolpidem tartrate salt I, with suitable fine-particle size for further biological experimentation.
Background: Cardiovascular disease remains the leading cause of death in the European Union and worldwide. Constant improvement in cardiac care is leading to an increased number of patients with heart failure, which is a challenging condition in terms of clinical management. Cardiac resynchronization therapy is becoming more popular because of its grounded position in guidelines and clinical practice. However, some patients do not respond to treatment as expected. One way of assessing cardiac resynchronization therapy is with ECG analysis. Artificial intelligence is increasing in terms of everyday usability due to the possibility of everyday workflow improvement and, as a result, shortens the time required for diagnosis. A special area of artificial intelligence is machine learning. AI algorithms learn on their own based on implemented data. The aim of this study was to evaluate using artificial intelligence algorithms for detecting inadequate resynchronization therapy. Methods: A total of 1241 ECG tracings were collected from 547 cardiac department patients. All ECG signals were analyzed by three independent cardiologists. Every signal event (QRS-complex) and rhythm was manually classified by the medical team and fully reviewed by additional cardiologists. The results were divided into two parts: 80% of the results were used to train the algorithm, and 20% were used for the test (Cardiomatics, Cracow, Poland). Results: The required level of detection sensitivity of effective cardiac resynchronization therapy stimulation was achieved: 99.2% with a precision of 92.4%. Conclusions: Artificial intelligence algorithms can be a useful tool in assessing the effectiveness of resynchronization therapy.
About Me
Clinical Project Manager at Cardiomatics, PhD Candidate at Jagiellonian University Collegium Medicum
Clinical Project Manager at Cardiomatics, PhD Candidate at Jagiellonian University Collegium Medicum