Ryan James McGlen

Prof. Dr. Ryan James McGlen

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2021 in Entropy
Verified
Journal Article
Open access
PDF file
PSPaweł Szymański
Paweł Szymański
RLRichard Law
Richard Law
RMRyan James McGlen
Ryan James McGlen
DRDavid A. Reay
David A. Reay
The focus of this review is to present the current advances in Loop Heat Pipes (LHP) with flat evaporators, which address the current challenges to the wide implementation of the technology. A recent advance in LHP is the design of flat-shaped evaporators, which is better suited to the geometry of discretely mounted electronics components (microprocessors) and therefore negate the need for an additional transfer surface (saddle) between component and evaporator. However, various challenges exist in the implementation of flat-evaporator, including (1) deformation of the evaporator due to high internal pressure and uneven stress distribution in the non-circular casing; (2) heat leak from evaporator heating zone and sidewall into the compensation chamber; (3) poor performance at start-up; (4) reverse flow through the wick; or (5) difficulties in sealing, and hence frequent leakage. This paper presents and reviews state-of-the-art LHP technologies; this includes an (a) review of novel manufacturing methods; (b) LHP evaporator designs; (c) working fluids; and (d) construction materials. The work presents solutions that are used to develop or improve the LHP construction, overall thermal performance, heat transfer distance, start-up time (especially at low heat loads), manufacturing cost, weight, possibilities of miniaturization and how they affect the solution on the above-presented problems and challenges in flat shape LHP development to take advantage in the passive cooling systems for electronic devices in multiple applications.

21 August 2025 in Journal of Power Sources
Verified
Journal Article
Open access
Joshua IrelandJoshua Ireland
Joshua Ireland
ZGZhen Guo
Zhen Guo
TDTruong Dinh
Truong Dinh
JMJames Marco
James Marco
RMRyan James McGlen
Ryan James McGlen
KLKevin Lynn
Kevin Lynn

21 January 2022 in Entropy
Verified
Journal Article
Open access
PDF file
PSPaweł Szymański
Paweł Szymański
RLRichard Law
Richard Law
RMRyan James McGlen
Ryan James McGlen
DRDavid A. Reay
David A. Reay
The author of the original publication

4 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
Joshua IrelandJoshua Ireland
Joshua Ireland
James MarcoJames Marco
James Marco
Truong Quang DinhTruong Quang Dinh
Truong Quang Dinh
RMRyan James McGlen
Ryan James McGlen
KLKevin Lynn
Kevin Lynn
Cylindrical Li-ion cells have found utilisation in numerous industries, but they are susceptible to thermal issues, and so they require suitable thermal management. One of the conceptual methods for addressing this issue is the introduction of a metallic mandrel inserted axially through the cell’s central cavity, which has previously been shown to have a thermal benefit through simulation, thermal emulation, and experimentally through bespoke functional test cells. This work has demonstrated the potential ability to modify a commercial LGM50 21700 cell to accept a 2 mm solid metal mandrel whilst maintaining functionality, and then to quantify the thermal behaviour under representative real-world operating conditions. The modification to external geometry is believed to have reduced the effective cooling area, and therefore leads to a temperature increase of 1–5.2 °C on the mandrel cell. The pristine reference cell then underwent the same external geometry modification, which showed no consistent thermal benefit compared to the mandrel cell, which was then validated through simulation. The simulated model evaluated the additional thermal resistances introduced by the modification process and highlighted the potential benefits of using a bespoke cell housing with an integrated mandrel over mandrel insertion. This was more significant under higher current loads, with a 7.2 °C maximum temperature reduction for the bespoke cell housing during a 3 C discharge.