Guoying Fan

Prof. Dr. Guoying Fan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2019 in Molecules
Verified
Journal Article
Open access
PDF file
LHLi Han
Li Han
YLYue-Tao Li
Yue-Tao Li
JJJin-Qing Jiang
Jin-Qing Jiang
RLRen-Feng Li
Ren-Feng Li
GFGuoying Fan
Guoying Fan
ZWZiliang Wang
Ziliang Wang
This study was conducted to develop a self-assembled direct competitive enzyme-linked immunosorbent assay (dcELISA) kit for the detection of deoxynivalenol (DON) in food and feed grains. Based on the preparation of anti-DON monoclonal antibodies, we established a standard curve with dcELISA and optimized the detection conditions. The performance of the kit was evaluated by comparison with high-performance liquid chromatography (HPLC). The minimum detection limit of DON with the kit was 0.62 ng/mL, the linear range was from 1.0 to 113.24 ng/mL and the half-maximal inhibition concentration (IC50) was 6.61 ng/mL in the working buffer; there was a limit of detection (LOD) of 62 ng/g, and the detection range was from 100 to 11324 ng/g in authentic agricultural samples. We examined four samples of wheat bran, wheat flour, corn flour and corn for DON recovery. The average recovery was in the range of 77.1% to 107.0%, and the relative standard deviation (RSD) ranged from 4.2% to 11.9%. In addition, the kit has the advantages of high specificity, good stability, a long effective life and negligible sample matrix interference. Finally, wheat samples from farms in the six provinces of Henan, Anhui, Hebei, Shandong, Jiangsu and Gansu in China were analyzed by the kit. A total of 30 samples were randomly checked (five samples in each province), and the results were in good agreement with the standardized HPLC method. These tests showed that the dcELISA kit had good performance and met relevant technical requirements, and it had the characteristics of accuracy, reliability, convenience and high-throughput screening for DON detection. Therefore, the developed kit is suitable for rapid screening of DON in marketed products.

27 February 2022 in Molecules
Verified
Journal Article
Open access
PDF file
XWXiaofei Wang
Xiaofei Wang
YWYanan Wang
Yanan Wang
SWShuyun Wang
Shuyun Wang
JHJie Hou
Jie Hou
LCLinlin Cai
Linlin Cai
GFGuoying Fan
Guoying Fan
Background: This study aimed to prepare monoclonal antibodies (mAbs) with high immunoreactivity, sensitivity, and specificity for the chelate (Cr(III)-EDTA) of trivalent chromium ion (Cr(III)) and ethylenediamine tetraacetic acid (EDTA). Further, the study established an indirect competitive enzyme-linked immunosorbent assay (icELISA) for detecting the total chromium content in food, feed, and environmental samples. Methods: Hapten Cr(III)-iEDTA was synthesized by chelating Cr(III) with isothiocyanatebenzyl-EDTA (iEDTA). Immunogen Cr(III)-iEDTA-BSA formed by chelating Cr(III)-iEDTA with bovine serum albumin (BSA), and coating antigen Cr(III)-iEDTA-OVA formed by chelating Cr(III)-iEDTA with ovalbumin (OVA) were prepared using the isothiocyanate method and identified by ultraviolet spectra (UV) and inductively coupled plasma optical emission spectrometry (ICP-OES). Balb/c mice were immunized with the Cr(III)-iEDTA-BSA, and the anti Cr(III)-EDTA mAb cell lines were screened by cell fusion. The Cr(III)-EDTA mAbs were prepared by induced ascites in vivo, and their immunological characteristics were assessed. Results: The immunogen Cr(III)-iEDTA-BSA was successfully synthesized, and the molecular binding ratio of Cr(III) to BSA was 15.48:1. Three hybridoma cell lines 2A3, 2A11, and 3D9 were screened, among which 2A3 was the best cell line. The 2A3 secreted antibody was stable after six passages, the affinity constant (Ka) was 2.69 × 109 L/mol, its 50% inhibition concentration (IC50) of Cr(III)-EDTA was 8.64 μg/L, and it had no cross-reactivity (CR%) with other heavy metal ion chelates except for a slight CR with Fe(III)-EDTA (1.12%). An icELISA detection method for Cr(III)-EDTA was established, with a limit of detection (LOD) of 1.0 μg/L and a working range of 1.13 to 66.30 μg/L. The average spiked recovery intra-assay rates were 90% to 109.5%, while the average recovery inter-assay rates were 90.4% to 97.2%. The intra-and inter-assay coefficient of variations (CVs) were 11.5% to 12.6% and 11.1% to 12.7%, respectively. The preliminary application of the icELISA and the comparison with ICP-OES showed that the coincidence rate of the two methods was 100%, and the correlation coefficient was 0.987. Conclusions: The study successfully established an icELISA method that meets the requirements for detecting the Cr(III)-EDTA chelate content in food, feed, and environmental samples, based on Cr(III)-EDTA mAb, and carried out its preliminary practical application.