Ketamine analogues have been emerging in recent years and are causing severe health and social problems worldwide. Ketamine analogues use 2-phenyl-2-aminocyclohexanone as the basic structure and achieve physiological reactions similar to or even more robust than the prototype of ketamine by changing the substituents on the benzene ring (R1 and R2) and amine group (RN1). Therefore, the mass spectrometry (MS) fragmentation pathways and fragments of ketamine analogues have certain regularity. Eight ketamine analogues are systematically investigated by GC-QTOF/MS and LC-Q-Orbitrap MS/MS with the positive mode of electrospray ionization. The MS fragmentation patterns of ketamine analogues are summarized according to high-resolution MS data. The α-cleavage of carbon bond C1-C2 in the cyclohexanone moiety and further losses of CO, methyl radical, ethyl radical and propyl radical are the characteristic fragmentation pathways of ketamine analogues in EI-MS mode. The loss of H2O or the sequential loss of RN1NH2, CO and C4H6 are the distinctive fragmentation pathways of ketamine analogues in ESI-MS/MS mode. Moreover, these MS fragmentation patterns are first introduced for the rapid screening of ketamine analogues in suspicious powder. Furthermore, the structure of the ketamine analogue in suspicious powder is 2-(Methylamino)-2-(o-tolyl)cyclohexan-1-one, which is further confirmed by NMR. This study contributes to the identification of the chemical structure of ketamine analogues, which can be used for the rapid screening of ketamine analogues in seized chemicals.
Abuse of illicit drugs has become a major issue of global concern. As a synthetic amphetamine analog, 3,4-Methylene Dioxy Amphetamine (MDA) causes serotonergic neurotoxicity, posing a serious risk to human health. In this work, a two-dimensional substrate of ITO/Au is fabricated by transferring Au nanoparticle film onto indium–tin oxide glass (ITO). By magnetic inducing assembly of Fe3O4@Au onto ITO/Au, a sandwich-based, surface-enhanced Raman scattering (SERS) detection strategy is designed. Through the use of an external magnet, the MDA is retained in the region of hot spots formed between Fe3O4@Au and ITO/Au; as a result, the SERS sensitivity for MDA is superior compared to other methods, lowering the limit of detection (LOD) to 0.0685 ng/mL and attaining a corresponding linear dynamic detection range of 5–105 ng/mL. As an actual application, this magnetically improved SERS sensing strategy is successfully applied to distinguish MDA in urine at trace level, which is beneficial to clinical and forensic monitors.
16 June 2025 in Journal of Pharmaceutical and Biomedical Analysis