Vai Alessandro

Dr. Vai Alessandro


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2023 in Radiotherapy and Oncology
Verified
Journal Article
Open access
NPNils Peters
Nils Peters
VTVicki Trier Taasti
Vicki Trier Taasti
BABenjamin Ackermann
Benjamin Ackermann
ABAlessandra Bolsi
Alessandra Bolsi
CDChristina Vallhagen Dahlgren
Christina Vallhagen Dahlgren
PWPatrick Wohlfahrt
Patrick Wohlfahrt
Studies have shown large variations in stopping-power ratio (SPR) prediction from computed tomography (CT) across European proton centres. To standardise this process, a step-by-step guide on specifying a Hounsfield look-up table (HLUT) is presented here. The HLUT specification process is divided into six steps: Phantom setup, CT acquisition, CT number extraction, SPR determination, HLUT specification, and HLUT validation. Appropriate CT phantoms have a head- and body-sized part, with tissue-equivalent inserts in regard to X-ray and proton interactions. CT numbers are extracted from a region-of-interest covering the inner 70% of each insert in-plane and several axial CT slices in scan direction. For optimal HLUT specification, the SPR of phantom inserts is measured in a proton beam and the SPR of tabulated human tissues is computed stoichiometrically at 100 MeV. Including both phantom inserts and tabulated human tissues increases HLUT stability. Piecewise linear regressions are performed between CT numbers and SPRs for four tissue groups (lung, adipose, soft tissue, and bone) and then connected with straight lines. Finally, a thorough but simple validation is performed. The best practices and individual challenges are explained comprehensively for each step. A well-defined strategy for specifying the connection points between the individual line segments of the HLUT is presented. The guide was tested exemplarily on three CT scanners from different vendors, proving its feasibility. The presented step-by-step guide for CT-based HLUT specification with recommendations and examples can contribute to reduce inter-centre variations in SPR prediction.

1 December 2016 in Physica Medica
Verified
Journal Article
Closed access
MCMario Ciocca
Mario Ciocca
AMAlfredo Mirandola
Alfredo Mirandola
SMSilvia Molinelli
Silvia Molinelli
SRStefania Russo
Stefania Russo
EMEdoardo Mastella
Edoardo Mastella
GBGuido Baroni
Guido Baroni

1 May 2020 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
EMEdoardo Mastella
Edoardo Mastella
SMSilvia Molinelli
Silvia Molinelli
APAndrea Pella
Andrea Pella
VAVai Alessandro
Vai Alessandro
DMDavide Maestri
Davide Maestri
MCMario Ciocca
Mario Ciocca

22 February 2022 in Cancers
Verified
Journal Article
Open access
PDF file
VAVai Alessandro
Vai Alessandro
SMSilvia Molinelli
Silvia Molinelli
EREleonora Rossi
Eleonora Rossi
NINicola Alessandro Iacovelli
Nicola Alessandro Iacovelli
Giuseppe MagroGiuseppe Magro
Giuseppe Magro
EOEster Orlandi
Ester Orlandi
(1) Background: we proposed an integrated strategy to support clinical allocation of nasopharyngeal patients between proton and photon radiotherapy. (2) Methods: intensity-modulated proton therapy (IMPT) plans were optimized for 50 consecutive nasopharyngeal carcinoma (NPC) patients treated with volumetric modulated arc therapy (VMAT), and differences in dose and normal tissue complication probability (ΔNTCPx-p) for 16 models were calculated. Patient eligibility for IMPT was assessed using a model-based selection (MBS) strategy following the results for 7/16 models describing the most clinically relevant endpoints, applying a model-specific ΔNTCPx-p threshold (15% to 5% depending on the severity of the complication) and a composite threshold (35%). In addition, a comprehensive toxicity score (CTS) was defined as the weighted sum of all 16 ΔNTCPx-p, where weights follow a clinical rationale. (3) Results: Dose deviations were in favor of IMPT (ΔDmean ≥ 14% for cord, esophagus, brainstem, and glottic larynx). The risk of toxicity significantly decreased for xerostomia (−12.5%), brain necrosis (−2.3%), mucositis (−3.2%), tinnitus (−8.6%), hypothyroidism (−9.3%), and trismus (−5.4%). There were 40% of the patients that resulted as eligible for IMPT, with a greater advantage for T3–T4 staging. Significantly different CTS were observed in patients qualifying for IMPT. (4) Conclusions: The MBS strategy successfully drives the clinical identification of NPC patients, who are most likely to benefit from IMPT. CTS summarizes well the expected global gain.

1 September 2019 in International Journal of Particle Therapy
Verified
Journal Article
Open access
VAVai Alessandro
Vai Alessandro
AMAlfredo Mirandola
Alfredo Mirandola
GMGiuseppe Magro
Giuseppe Magro
DMDavide Maestri
Davide Maestri
EMEdoardo Mastella
Edoardo Mastella
MCMario Ciocca
Mario Ciocca
Purpose: Beam energy validation is a fundamental aspect of the routine quality assurance (QA) protocol of a particle therapy facility. A multilayer ionization chamber (MLIC) detector provi...

14 February 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
GPGiovanni Parrella
Giovanni Parrella
VAVai Alessandro
Vai Alessandro
ANAnestis Nakas
Anestis Nakas
NGNoemi Garau
Noemi Garau
GMGiorgia Meschini
Giorgia Meschini
GBGuido Baroni
Guido Baroni
The generation of synthetic CT for carbon ion radiotherapy (CIRT) applications is challenging, since high accuracy is required in treatment planning and delivery, especially in an anatomical site as complex as the abdomen. Thirty-nine abdominal MRI-CT volume pairs were collected and a three-channel cGAN (accounting for air, bones, soft tissues) was used to generate sCTs. The network was tested on five held-out MRI volumes for two scenarios: (i) a CT-based segmentation of the MRI channels, to assess the quality of sCTs and (ii) an MRI manual segmentation, to simulate an MRI-only treatment scenario. The sCTs were evaluated by means of similarity metrics (e.g., mean absolute error, MAE) and geometrical criteria (e.g., dice coefficient). Recalculated CIRT plans were evaluated through dose volume histogram, gamma analysis and range shift analysis. The CT-based test set presented optimal MAE on bones (86.03 ± 10.76 HU), soft tissues (55.39 ± 3.41 HU) and air (54.42 ± 11.48 HU). Higher values were obtained from the MRI-only test set (MAEBONE = 154.87 ± 22.90 HU). The global gamma pass rate reached 94.88 ± 4.9% with 3%/3 mm, while the range shift reached a median (IQR) of 0.98 (3.64) mm. The three-channel cGAN can generate acceptable abdominal sCTs and allow for CIRT dose recalculations comparable to the clinical plans.