Miryam Calvino

Dr. Miryam Calvino

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
LLLuis Lassaletta
Luis Lassaletta
MCMiryam Calvino
Miryam Calvino
ISIsabel Sanchez-Cuadrado
Isabel Sanchez-Cuadrado
Piotr H. SkarzynskiPiotr H. Skarzynski
Piotr H. Skarzynski
KCKatarzyna Cywka
Katarzyna Cywka
JZJulia Speranza Zabeu
Julia Speranza Zabeu
The primary objectives of this study were to evaluate the effect of hearing implant (HI) use on quality of life (QoL) and to determine which QoL measure(s) quantify QoL with greater sensitivity in users of different types of HIs. Participants were adult cochlear implant (CI), active middle ear implant (VIBRANT SOUNDBRIDGE (VSB)), or active transcutaneous bone conduction implant (the BONEBRIDGE (BB)) recipients. Generic QoL and disease-specific QoL were assessed at three intervals: pre-activation, 6 months of device use, and 12 months of device use. 169 participants completed the study (110 CI, 18VSB, and 41BB). CI users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. On some device-specific measures, their QoL also significantly increased between 6 and 12 m device use. VSB users’ QoL significantly increased between all tested intervals with the disease-specific measure but not the generic measure. BB users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. In sum, HI users experienced significant postoperative increases in QoL within their first 12 m of device use, especially when disease-specific measures were used. Disease-specific QoL measures appeared to be more sensitive than their generic counterparts.

29 November 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
GMGriet Mertens
Griet Mertens
EAEllen Andries
Ellen Andries
AKAnja Kurz
Anja Kurz
DTDayse Távora-Vieira
Dayse Távora-Vieira
MCMiryam Calvino
Miryam Calvino
ALArtur Lorens
Artur Lorens
The study aimed to develop a consensus classification system for the reporting of sound localization testing results, especially in the field of cochlear implantation. Against the background of an overview of the wide variations present in localization testing procedures and reporting metrics, a novel classification system was proposed to report localization errors according to the widely accepted International Classification of Functioning, Disability and Health (ICF) framework. The obtained HEARRING_LOC_ICF scale includes the ICF graded scale: 0 (no impairment), 1 (mild impairment), 2 (moderate impairment), 3 (severe impairment), and 4 (complete impairment). Improvement of comparability of localization results across institutes, localization testing setups, and listeners was demonstrated by applying the classification system retrospectively to data obtained from cohorts of normal-hearing and cochlear implant listeners at our institutes. The application of our classification system will help to facilitate multi-center studies, as well as allowing better meta-analyses of data, resulting in improved evidence-based practice in the field.

LLLuis Lassaletta
Luis Lassaletta
MCMiryam Calvino
Miryam Calvino
ISIsabel Sanchez-Cuadrado
Isabel Sanchez-Cuadrado
Piotr H. SkarzynskiPiotr H. Skarzynski
Piotr H. Skarzynski
KCKatarzyna Cywka
Katarzyna Cywka
JZJulia Speranza Zabeu
Julia Speranza Zabeu
This study aimed to report quality of life (QoL) scores in unilateral cochlear implant (CI) users and to generate guidance for clinicians on using QoL measures to individualize CI counselling and rehabilitation and to increase access to CIs as a mode of rehabilitation. Participants (n = 101) were unilateral CI users with single-sided deafness (SSD; n = 17), asymmetrical hearing loss (AHL; n = 26), or bilateral hearing loss (Uni; n = 58). Generic QoL was assessed via the Health Utilities Index (HUI-3), and disease-specific QoL was assessed via the Speech, Spatial, and Qualities of Hearing scale (SSQ12) and Nijmegen CI Questionnaire (NCIQ) at preimplantation and at 6 and 12 months of CI use. All groups had significantly increased HUI-3 scores at both intervals. The SSD group showed significant benefit on the SSQ12 at visit 3, the AHL group showed significant benefit on the SSQ12 and most NCIQ subdomains at both intervals, and the Uni group showed significant benefit with both tests at both intervals. Unilateral CI recipients demonstrate improved QoL within the first 12 months of device use. Regular assessment with generic and disease-specific questionnaires has the potential to play an important role in personalizing treatment and possibly in increasing access to CI provision.

23 March 2024 in Hearing Research
Verified
Journal Article
Closed access
LLLuis Lassaletta
Luis Lassaletta
MCMiryam Calvino
Miryam Calvino
MDMiguel Díaz
Miguel Díaz
JMJosé Manuel Morales-Puebla
José Manuel Morales-Puebla
ISIsabel Sánchez-Cuadrado
Isabel Sánchez-Cuadrado
JGJavier Gavilán
Javier Gavilán

MCMiryam Calvino
Miryam Calvino
ISIsabel Sanchez-Cuadrado
Isabel Sanchez-Cuadrado
JGJavier Gavilan
Javier Gavilan
LLLuis Lassaletta
Luis Lassaletta
Background: Although it is a recognized phenomenon, there is little published in the literature on the discontinuation of auditory implant use. Aim: To evaluate the incidence of device non-use of transcutaneous auditory implants. Patients and Methods: This is a retrospective study of all living individuals (children and adults) implanted at the La Paz Hospital (Madrid, Spain) between 1992–2015, with a follow-up examination endpoint of December 2022. 356 device recipients were included: 316 with cochlear implants (CI), 22 with middle-ear implants (Vibrant Soundbridge, VSB), and 18 with bone conduction implants (Bonebridge, BB). Results: Nine CI recipients (2.8%) were identified as non-users (mean follow-up 15.1 ± 5.4 years). The reasons for non-use were implant failure and reimplantation rejection, lack of benefit, non-attendance of rehabilitation sessions, loss of the audio processor, and cognitive and linguistic difficulties. None of them experienced any surgical complications. Six VSB recipients (27.3%) were device non-users (mean follow-up 11.4 ± 2.1 years). All of them experienced device failure or surgical complications. To date, none of the BB recipients is a non-user (mean follow-up 8.6 ± 1.1 years). Conclusion: The rates of non-use of transcutaneous auditory implants vary widely between different types of implants. Given the small proportion of non-users, information on what are the predictive factors could not be determined. The reasons for non-use should be carefully documented and used to guide careful patient selection to reduce the risk of non-use in future candidates.

22 July 2023 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
PDF file
MCMiryam Calvino
Miryam Calvino
AZAlejandro Zuazua
Alejandro Zuazua
ISIsabel Sanchez-Cuadrado
Isabel Sanchez-Cuadrado
JGJavier Gavilán
Javier Gavilán
MMMarta Mancheño
Marta Mancheño
LLLuis Lassaletta
Luis Lassaletta
Purpose: Music perception is one of the greatest challenges for cochlear implant (CI) users. The aims of this study were: (i) to evaluate the music perception of CI users using the online Meludia music training program as music testing platform, (ii) to compare performance among three age groups, and (iii) to compare CI users with their normal hearing (NH) peers. Methods: 138 individuals participated, divided between children (6–10 y), adolescents (11–16 y), and adults (≥ 17 y). Five music perception tasks were evaluated: Rhythm, Spatialization, Stable/unstable, Melody, and Density. We also administered the music related quality of life (MuRQoL) questionnaire for adults, and a music questionnaire for pediatric population (6–16 y) (MuQPP). Results: A significantly higher percentage of the adolescent CI users completed the five tasks compared to the other age groups. Both pediatric and adolescent CI users had similar performance to their NH peers in most categories. On the MuRQoL, adult NH listeners reported more music exposure than CI users (3.8 ± 0.6 vs 3.0 ± 0.6, p < 0.01), but both groups reported similar levels of perceived music importance (3.4 ± 0.7 vs 3.2 ± 1.1, p = 0.340). On the MuQPP, pediatric CI users who scored highly on music perception also had higher reported questionnaire scores (54.2 ± 12.9 vs 40.9 ± 12.1, p = 0.009). Conclusions: Meludia can be used to evaluate music perception and to use for music training in CI users of all ages. Adolescents had the highest performance in most musical tasks. Pediatric CI users were more similar to their NH peers. The importance of music in adult CI users was comparable to their NH peers.