Hugo Alexandre Ferreira

Prof. Hugo Alexandre Ferreira

Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências da Universidade de Lisboa, 1649-004 Lisboa, Portugal
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2004 in Trends in Biotechnology
Verified
Journal Article
Closed access
DGDaniel L. Graham
Daniel L. Graham
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
PFPaulo Freitas*
Paulo Freitas*

20 May 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
LEL. Ejsing
L. Ejsing
MHM. F. Hansen
M. F. Hansen
AMA. K. Menon
A. K. Menon
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
DGD. L. Graham
D. L. Graham
PFPaulo Freitas*
Paulo Freitas*
Magnetic bead sensors based on the planar Hall effect in thin films of exchange-biased permalloy have been fabricated and characterized. Typical sensitivities are 3 μV/Oe mA. The sensor response to an applied magnetic field has been measured without and with coatings of commercially available 2 μm and 250 nm magnetic beads used for bioapplications (Micromer-M and Nanomag-D, Micromod, Germany). Detection of both types of beads and single bead detection of 2 μm beads is demonstrated, i.e., the technique is feasible for magnetic biosensors. Single 2 μm beads yield 300 nV signals at 10 mA and 15 Oe applied field.

9 May 2003 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
DGD. L. Graham
D. L. Graham
PFPaulo Freitas*
Paulo Freitas*
Joaquim M.S. CabralJoaquim M.S. Cabral
Joaquim M.S. Cabral
On-chip spin-valve sensors (2×6 μm2) were used to detect the binding of streptavidin-functionalized superparamagnetic labels to sensor surface-bound biotin. Both micron-sized and nanometer-sized labels were studied. The detection of biomolecular recognition was demonstrated using 2 μm Micromer®-M and 250 nm Nanomag®-D labels, with signals ranging from ∼300 μV to ∼2 mV (8 mA sense current; ∼15 Oe in-plane magnetizing fields). For smaller labels, detection of biomolecular recognition was not achieved. The capability of detecting single labels was demonstrated for label moments down to 2×10−12 emu (2 μm labels), corresponding to signals of 100–400 μV. Although, theoretical calculations suggest that the minimum measurable moment is in the order of 6×10−15 emu, due to noise limitations of the present setup, this limit is in the order of 2×10−13 emu, corresponding to a single 250 nm label. On-chip tapered aluminum current line structures were used for placement of magnetic labels at sensor sites.

13 May 2002 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
DGD. L. Graham
D. L. Graham
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
JBJ. Bernardo
J. Bernardo
PFPaulo Freitas*
Paulo Freitas*
Joaquim M.S. CabralJoaquim M.S. Cabral
Joaquim M.S. Cabral
Superparamagnetic labels, 400 nm dextran iron oxide particles and 2 μm polymer encapsulated iron oxide microspheres, with biomolecules immobilized on the surface, e.g., the enzyme horseradish peroxidase (20–40 molecules per label) were controllably placed on chip sites (5×15 μm2) using tapered Al current lines (10–20 mA current) and moved to and from adjacent spin valve sensors [2×6 μm,2, magnetoresistance (MR) ∼5%]. Average MR signals of 1.2 and 0.6 mV were obtained for the detection of bulk numbers of 400 nm and 2 μm labels respectively using an on-chip field of 15 Oe and a sense current of 5 mA. The moment per label was calculated at 5×10−13 emu for the 400 nm labels and 5×10−12 emu for the 2 μm labels, illustrating the higher density of the 400 nm particles. MR signals of ∼100 μV were obtained for single 2 μm labels positioned over the spin valve sensor using an on-chip field of 15 Oe and 8 mA sense current. The corresponding sensor saturation occurred at ∼1 mV, with a noise level of ∼10 μV. The estimated maximum MR signal for one 2 μm label directly on top of the sensor was ∼400 μV. Biotechnological applications include high sensitivity biosensors and biochips for protein and DNA screening.

1 December 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
BSBeatriz Sequeira-Antunes
Beatriz Sequeira-Antunes
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
Aptamers, short strands of either DNA, RNA, or peptides, known for their exceptional specificity and high binding affinity to target molecules, are providing significant advancements in the field of health. When seamlessly integrated into biosensor platforms, aptamers give rise to aptasensors, unlocking a new dimension in point-of-care diagnostics with rapid response times and remarkable versatility. As such, this review aims to present an overview of the distinct advantages conferred by aptamers over traditional antibodies as the molecular recognition element in biosensors. Additionally, it delves into the realm of specific aptamers made for the detection of biomarkers associated with infectious diseases, cancer, cardiovascular diseases, and metabolomic and neurological disorders. The review further elucidates the varying binding assays and transducer techniques that support the development of aptasensors. Ultimately, this review discusses the current state of point-of-care diagnostics facilitated by aptasensors and underscores the immense potential of these technologies in advancing the landscape of healthcare delivery.

2 December 2002 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DGD.L Graham
D.L Graham
HFHugo Alexandre Ferreira
Hugo Alexandre Ferreira
PFPaulo Freitas*
Paulo Freitas*
Joaquim M.S. CabralJoaquim M.S. Cabral
Joaquim M.S. Cabral