The goal of this study was to evaluate electrical field interactions produced by the stimulation of different types of intracochlear electrodes in 12 adult subjects (three Ineraid™, four Clarion™ S-Series, three S-Series with the electrode positioning system-EPS and two Clarion™ HiFocus-I with the EPS). Psychophysical measurements were conducted with biphasic stimuli (813 pulse per second, 153.8 μs/phase). “Perturbation” signals (300 ms) were applied to one electrode chosen at the middle of the array and their effects on detection thresholds of “probe” signals (30 ms) were measured on the neighbor basal electrode. Perturbation levels were set below the detection threshold of the perturbation electrode (−2 dB threshold). Measurements were first conducted for simultaneous stimulation of the probe and of the perturbation electrodes, for monopolar for all subjects and for bipolar stimulus configurations for both Clarion™ HiFocus-I subjects. The tested Clarion™ electrodes did not present lower monopolar interactions than the Ineraid™ electrodes. Nevertheless, considering the shorter distance between electrodes for the Clarion™ than for the Ineraid™, the tested Clarion™ electrodes might be more selective than the Ineraid™. We did not find any significant monopolar electrical field-interaction differences between subjects who received the S-Series array with and without the EPS. We did not find lower interactions for both subjects who received the HiFocus-I array than for subjects who received the S-Series. Electrical field interactions were lower for bipolar than for monopolar configurations for both HiFocus-I subjects. A second set of measurements was conducted for nonsimultaneous stimulation similar to the one used in continuous interleaved sampling sound strategy. These measurements showed that interactions evaluated for simultaneous biphasic stimuli were larger than for nonsimultaneous stimulation.
1 October 2003 in The Journal of the Acoustical Society of America
The goal of this study was to evaluate, from a psychophysical standpoint, the neural spread of excitation produced by the stimulation of different types of intracochlear electrode arrays: the Ineraid™, the Clarion™ S-Series on its own or with the Electrode Positioning System (EPS), and the Clarion™ HiFocus-I with the EPS. The EPS is an independent silicone part designed to bring the electrode array close to the modiolus. Forward masking was evaluated in 12 adult subjects (3 Ineraid™, 4 Clarion™ S-Series, 3 Clarion™ S-Series+EPS, 3 HiFocus-I+EPS) by psychophysical experiments conducted using trains of biphasic stimuli (813 pulses per second, 307.6 μs/phase). Masker signals (+8 dB re: threshold, 300 ms) were applied to the most apical electrode. Probe signals (30 ms, 10-ms postmasker) were delivered to more basal electrodes. Masked and unmasked detection thresholds of probe signals were measured. For both Clarion™ HiFocus-I subjects, measurements were conducted in both monopolar and bipolar stimulus configurations. No major differences were found in forward masking between the different intracochlear electrode arrays tested in the monopolar configuration at suprathreshold levels equivalent to those used in speech-coding strategies, but significant differences were found between subjects. A significant negative correlation also was found between the level of forward masking and the consonant identification performance. These measurements showed that the neural spread of excitation was more restricted in the bipolar configuration than in the monopolar configuration for HiFocus-I subjects. It was found that CIS strategies implemented without using apical electrodes, which showed high levels of masking, could improve consonant identification.