Chiung-Wen Hu

Prof. Dr. Chiung-Wen Hu

Department of Public Health, Chung Shan Medical University, Taichung, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 June 2013 in Antioxidants & Redox Signaling
Verified
Journal Article
Open access
LBLars Barregård
Lars Barregård
PMPeter Møller
Peter Møller
THTrine Henriksen
Trine Henriksen
VMVilas Mistry
Vilas Mistry
GKGudrun Koppen
Gudrun Koppen
MCMarcus Cooke
Marcus Cooke
Aims: Urinary 8-oxo-7,8-dihydro-2′-deoxyguanosine (8-oxodG) is a widely used biomarker of oxidative stress. However, variability between chromatographic and ELISA methods hampers interpretation of data, and this variability may increase should urine composition differ between individuals, leading to assay interference. Furthermore, optimal urine sampling conditions are not well defined. We performed inter-laboratory comparisons of 8-oxodG measurement between mass spectrometric-, electrochemical- and ELISA-based methods, using common within-technique calibrants to analyze 8-oxodG-spiked phosphate-buffered saline and urine samples. We also investigated human subject- and sample collection-related variables, as potential sources of variability. Results: Chromatographic assays showed high agreement across urines from different subjects, whereas ELISAs showed far more inter-laboratory variation and generally overestimated levels, compared to the chromatographic assays. Excretion rates in timed ‘spot’ samples showed strong correlations with 24 h excretion (the ‘gold’ standard) of urinary 8-oxodG (r p 0.67–0.90), although the associations were weaker for 8-oxodG adjusted for creatinine or specific gravity (SG). The within-individual excretion of 8-oxodG varied only moderately between days (CV 17% for 24 h excretion and 20% for first void, creatinine-corrected samples). Innovation: This is the first comprehensive study of both human and methodological factors influencing 8-oxodG measurement, providing key information for future studies with this important biomarker. Conclusion: ELISA variability is greater than chromatographic assay variability, and cannot determine absolute levels of 8-oxodG. Use of standardized calibrants greatly improves intra-technique agreement and, for the chromatographic assays, importantly allows integration of results for pooled analyses. If 24 h samples are not feasible, creatinine- or SG-adjusted first morning samples are recommended. Antioxid. Redox Signal. 18, 2377–2391.

27 January 2004 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
Chiung-Wen HuChiung-Wen Hu
Chiung-Wen Hu
MWMing‐Tsang Wu
Ming‐Tsang Wu
Mu-Rong ChaoMu-Rong Chao
Mu-Rong Chao
CPChih‐Hong Pan
Chih‐Hong Pan
CWChien‐Jen Wang
Chien‐Jen Wang
KWKuenyuh Wu
Kuenyuh Wu


1 April 2002 in Process Biochemistry
Verified
Journal Article
Closed access
Chiung-Wen HuChiung-Wen Hu
Chiung-Wen Hu
KTK Thayanithy
K Thayanithy
CFC.F Forster
C.F Forster


1 June 2003 in Atmospheric Environment
Verified
Journal Article
Closed access
Chiung-Wen HuChiung-Wen Hu
Chiung-Wen Hu
Mu-Rong ChaoMu-Rong Chao
Mu-Rong Chao
KWKuenyuh Wu
Kuenyuh Wu
GCGou-Ping Chang-Chien
Gou-Ping Chang-Chien
WLWen-Jhy Lee
Wen-Jhy Lee
WLWei-Shan Lee
Wei-Shan Lee