The development of thermal control systems has become an important issue in next-generation electric aircraft design due to the increase in heat exhausted with electrification. In this paper, a wick-type two-phase mechanically pumped fluid loop system for future electric aircraft was proposed through the investigation of current two-phase flow cooling technology. Taking the experimental electric aircraft X-57 as an example, a wick-type two-phase mechanically pumped fluid loop with four evaporators for transporting 12 kW of waste heat within an 80 °C temperature limit was proposed and its feasibility was confirmed. A numerical model was constructed and validated to predict the operating characteristics of a two-phase mechanically pumped fluid loop. The optimal pump outputs under-even and uneven heat load conditions and was investigated for the first time by considering the vapor-liquid separation conditions in each flow path and the power consumption of the pump. Under the optimal pump output condition, the operating characteristics of the wick-type two-phase mechanically pumped fluid loop system were calculated. The calculation results indicate that the proposed wick-type two-phase mechanically pumped fluid loop is suitable as the thermal control system for an X-57 electric aircraft motor, as the calculation results satisfied the operational requirements of the motor.
4 September 2023 in ASME Journal of Heat and Mass Transfer
In this paper, the operating characteristics of the heat load sharing mode of multiple-evaporator loop heat pipe (MLHP) were elucidated based on a visual observation test. The heat load sharing mode is a function of MLHPs that can share the heat between the evaporators through the vapor without electronic power for the heat storage utilization. A visualized MLHP with two evaporators and one condenser was designed and fabricated. To simulate the heat load sharing mode in the MLHP, one evaporator was heated in the range of 40–280 W and the other evaporator was cooled using a water jacket in the range of 10–80 °C. Under the heat load sharing mode, the flow behaviors in the evaporator cores and the compensation chambers were visually observed using borescope cameras, respectively. Moreover, two operating modes (defined as Mode A and Mode B) that affect the maximum heat sharing capability were identified. In Mode A, the heat sharing rate was proportional to the heat dissipation at the cooled side of evaporator, where the capillary force at the wick significantly affected the operation mode. By contrast, in Mode B, the heat sharing rate reached the upper limit and then was constant regardless of the heat dissipation. Furthermore, the proposed concept model can predict the transition of the operation mode from Mode A to Mode B.
8 June 2024 in International Journal of Heat and Mass Transfer