Oriel Thekisoe

Prof. Oriel Thekisoe

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ThankGod OnyicheThankGod Onyiche
ThankGod Onyiche
SKSUGANUMA Keisuke
SUGANUMA Keisuke
Ikuo IgarashiIkuo Igarashi
Ikuo Igarashi
NYNaoaki Yokoyama
Naoaki Yokoyama
Xuenan XuanXuenan Xuan
Xuenan Xuan
OTOriel Thekisoe
Oriel Thekisoe
Equine Piroplasmosis (EP) is a tick-borne disease caused by apicomplexan protozoan parasites, Babesia caballi and Theileria equi. The disease is responsible for serious economic losses to the equine industry. It principally affects donkeys, horses, mules, and zebra but DNA of the parasites has also been detected in dogs and camels raising doubt about their host specificity. The disease is endemic in tropical and temperate regions of the world where the competent tick vectors are prevalent. Infected equids remain carrier for life with T. equi infection, whilst, infection with B. caballi is cleared within a few years. This review focuses on all aspects of the disease from the historical overview, biology of the parasite, epidemiology of the disease (specifically highlighting other non-equine hosts, such as dogs and camels), vector, clinical manifestations, risk factors, immunology, genetic diversity, diagnosis, treatment, and prevention.

1 December 2007 in Journal of Microbiological Methods
Verified
Journal Article
Closed access
HIHiroshi Iseki
Hiroshi Iseki
AAAndy Alhassan
Andy Alhassan
NONaomi Ohta
Naomi Ohta
OTOriel Thekisoe
Oriel Thekisoe
NYNaoaki Yokoyama
Naoaki Yokoyama
IIIkuo Igarashi
Ikuo Igarashi

1 September 2007 in Applied and Environmental Microbiology
Verified
Journal Article
Closed access
Panagiotis KaranisPanagiotis Karanis
Panagiotis Karanis
OTOriel Thekisoe
Oriel Thekisoe
KKKlytaimnistra Kiouptsi
Klytaimnistra Kiouptsi
JOJerry Ongerth
Jerry Ongerth
IIIkuo Igarashi
Ikuo Igarashi
NINoborou Inoue
Noborou Inoue
A loop-mediated isothermal amplification (LAMP) procedure for the detection of Cryptosporidium in environmental and fecal samples was developed and evaluated. This is the first demonstration of LAMP applied to detection of Cryptosporidium . Due to its specificity and simplicity, the method could become a useful diagnostic tool for epidemiologic studies of Cryptosporidium presence.

1 November 2008 in Veterinary Parasitology
Verified
Journal Article
Closed access
MBMohammed A. Bakheit
Mohammed A. Bakheit
DTDena Torra
Dena Torra
LPLily A. Palomino
Lily A. Palomino
OTOriel Thekisoe
Oriel Thekisoe
PMPeter A. Mbati
Peter A. Mbati
PKPanagiotis Karanis
Panagiotis Karanis

1 June 2007 in Acta Tropica
Verified
Journal Article
Closed access
OTOriel Thekisoe
Oriel Thekisoe
NKNoritaka Kuboki
Noritaka Kuboki
ANAndrew Nambota
Andrew Nambota
KFKozo Fujisaki
Kozo Fujisaki
CSChihiro Sugimoto
Chihiro Sugimoto
NINoboru Inoue
Noboru Inoue

1 July 2010 in The American Journal of Tropical Medicine and Hygiene
Verified
Journal Article
Closed access
BPBirgit Pöschl
Birgit Pöschl
JWJarurin Waneesorn
Jarurin Waneesorn
OTOriel Thekisoe
Oriel Thekisoe
SCSalakchit Chutipongvivate
Salakchit Chutipongvivate
Panagiotis KaranisPanagiotis Karanis
Panagiotis Karanis
Three methods, microscopy, nested polymerase chain reaction (nPCR), and loop-mediated isothermal amplification (LAMP) have been applied for malaria diagnosis in 105 human blood samples collected in Northern Thailand. Only Plasmodium falciparum and Plasmodium vivax infections were detected. A total number of 57 positives (54%) could be detected for P. falciparum and 25 (24%) for P. vivax when all samples that were positive in any of the three methods are counted together. The nPCR was used as a reference standard for comparison with the other methods, microscopy and LAMP. The sensitivity of LAMP for P. falciparum was 100%. All nPCR-negative samples for P. falciparum were also negative by both microscopy and LAMP (specificity, 100%). For diagnosis of P. vivax, microscopy detected 15 of 23 nPCR-positive samples (sensitivity, 65%). LAMP detected 22 of 23 nPCR-positives (sensitivity, 96%). Among the 82 nPCR-negative samples microscopy detected two samples (specificity, 98%). All 82 nPCR-negative were also negative by the LAMP method (specificity, 100%). Both Plasmodium genus- and species-specific LAMP primer sets yielded the same results in all samples. There were no significant differences in the prevalence detected by each method. We assume that LAMP was as reliable as nPCR and more reliable than microscopy in the detection of Plasmodium DNA tested in the examined Thai field blood samples. This study further validates LAMP as an alternative molecular diagnostic tool, which can be used in the diagnosis of early infections of malaria cases and together with nPCR can also be used as supplementary methods for clinical and epidemiological use.