By tradition colloid solutions have been used to obtain fast circulatory stabilisation in shock, but high molecular weight hydroxyethyl starch (HES) may cause acute kidney failure in patients with severe sepsis. Now lower molecular weight HES 130/0.4 is the preferred colloid in Scandinavian intensive care units (ICUs) and 1st choice fluid for patients with severe sepsis. However, HES 130/0.4 is largely unstudied in patients with severe sepsis. The 6S trial will randomise 800 patients with severe sepsis in 30 Scandinavian ICUs to masked fluid resuscitation using either 6% HES 130/0.4 in Ringer's acetate or Ringer's acetate alone. The composite endpoint of 90-day mortality or end-stage kidney failure is the primary outcome measure. The secondary outcome measures are severe bleeding or allergic reactions, organ failure, acute kidney failure, days alive without renal replacement therapy or ventilator support and 28-day and 1/2- and one-year mortality. The sample size will allow the detection of a 10% absolute difference between the two groups in the composite endpoint with a power of 80%. The 6S trial will provide important safety and efficacy data on the use of HES 130/0.4 in patients with severe sepsis. The effects on mortality, dialysis-dependency, time on ventilator, bleeding and markers of resuscitation, metabolism, kidney failure, and coagulation will be assessed. ClinicalTrials.gov: NCT00962156
6 June 2014 in Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Concern has been raised that cervical collars may increase intracranial pressure in traumatic brain injury. The purpose of this study was to compare four types of cervical collars regarding efficacy of immobilizing the neck, effect on jugular venous pressure (JVP), as a surrogate for possible effect on intracranial pressure, and patient comfort in healthy volunteers.
25 February 2013 in Acta Anaesthesiologica Scandinavica
Background: Infections are a frequent complication of cardiac surgery. The intraoperative use of transesophageal echocardiography (TEE) may be an underrecognized risk factor for post‐operative infections. The aim of this study was to investigate infection rates and outcomes after cardiac surgery in a nationwide cohort, especially in relation to periods where surface damaged TEE probes were used.Methods: This was a retrospective, observational study at Landspitali University Hospital. All consecutive cardiac surgery patients from 1 January 2013 to 31 December 2017 were included. Patients’ charts were reviewed for evidence of infection, post‐operative complications or death.Results: During the study period, 973 patients underwent cardiac surgery at Landspitali and 198 (20.3%) developed a post‐operative infection. The most common infections were: Pneumonia (9.1%), superficial surgical site (5.7%), bloodstream (2.8%) and deep sternal wound (1.7%). Risk factors for developing an infection included: The duration of procedure, age, insulin‐dependent diabetes, EuroScore II, reoperation for bleeding and an operation in a period with a surface damaged TEE probe in use. Twenty‐two patients were infected with a multidrug resistant strain of Klebsiella oxytoca, 10 patients with Pseudomonas aeruginosa and two patients developed endocarditis with Enterococcus faecalis. All three pathogens were cultured from the TEE probe in use at respective time, after decontamination. The 30‐day mortality rate in the patient cohort was 3.2%.Conclusions: The intraoperative use of surface damaged TEE probes caused two serious infection outbreaks in patients after cardiac surgery. TEE probes need careful visual inspection during decontamination and probe sheaths are recommended.