Robert Lämmer

Prof. Dr. Robert Lämmer

University of Erlangen-Nuremberg, Erlangen, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2010 in Journal of Glaucoma
Verified
Journal Article
Closed access
DBDelia Bendschneider
Delia Bendschneider
RTRalf P. Tornow
Ralf P. Tornow
FHFolkert K. Horn
Folkert K. Horn
RLRobert Lämmer
Robert Lämmer
CRChristopher W. Roessler
Christopher W. Roessler
CMChristian Y. Mardin
Christian Y. Mardin
To determine normal values for peripapillary retinal nerve fiber layer thickness (RNFL) measured by spectral domain Optical Coherence Tomography (SOCT) in healthy white adults and to examine the relationship of RNFL with age, gender, and clinical variables. The peripapillary RNFL of 170 healthy patients (96 males and 74 females, age 20 to 78 y) was imaged with a high-resolution SOCT (Spectralis HRA+OCT, Heidelberg Engineering) in an observational cross-sectional study. RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive circular B-scans with 3.4-mm diameter. The automatically segmented RNFL thickness was divided into 32 segments (11.25 degrees each). One randomly selected eye per subject entered the study. Mean RNFL thickness in the study population was 97.2 ± 9.7 μm. Mean RNFL thickness was significantly negatively correlated with age (r = -0.214, P = 0.005), mean RNFL decrease per decade was 1.90 μm. As age dependency was different in different segments, age-correction of RNFL values was made for all segments separately. Age-adjusted RNFL thickness showed a significant correlation with axial length (r = -0.391, P = 0.001) and with refractive error (r = 0.396, P<0.001), but not with disc size (r = 0.124). Normal RNFL results with SOCT are comparable to those reported with time-domain OCT. In accordance with the literature on other devices, RNFL thickness measured with SOCT was significantly correlated with age and axial length. For creating a normative database of SOCT RNFL values have to be age adjusted.

11 August 2007 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
BHBettina Hohberger
Bettina Hohberger
RLRobert Lämmer
Robert Lämmer
WAWerner Adler
Werner Adler
AJAnselm G. M. Juenemann
Anselm G. M. Juenemann
FHFolkert K. Horn
Folkert K. Horn

1 April 2008 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
FPFrancesca Pasutto
Francesca Pasutto
MKMandy Krumbiegel
Mandy Krumbiegel
CMChristian Y. Mardin
Christian Y. Mardin
DPDaniela Paoli
Daniela Paoli
RLRobert Lämmer
Robert Lämmer
ARAndré Reis
André Reis
Purpose. Three common sequence variants in the lysyl oxidase-like 1 (LOXL1) gene were recently associated with both pseudoexfoliation (PEX) and pseudoexfoliation glaucoma (PEXG) in populations from Iceland and Sweden. In this study, the genetic association of these variants was investigated in patients with PEX or PEXG of German and Italian descent. methods. The three LOXL1 single-nucleotide polymorphisms (SNPs), one intronic (rs2165241) and two nonsynonymous coding SNPs (rs1048661: R141L and rs3825942: G153D) were genotyped in a total of 726 unrelated patients with PEX or PEXG (517 Germans and 209 Italians) and 418 healthy subjects who had normal findings in repeated ophthalmic examinations, and a genetic association study was performed. results. Strong association with the three LOXL1 common sequence variants was seen in both the PEX and PEXG patient groups independent of their geographic origin (rs2165241, combined OR = 3.42, P = 1.28 × 10−40; rs1048661, OR = 2.43, P = 2.90 × 10−19; and rs3825942, OR = 4.87, P = 8.22 × 10−23). Similarly, the common frequent haplotype (G-G) composed of the two coding SNPs (rs1048661 and rs3825942) was strongly associated in PEX and PEXG cohorts of both populations with the disease (combined OR = 3.58, P = 5.21× 10−43). conclusions. Genetic variants in LOXL1 confer risk to PEX in German and Italian populations, independent of the presence of secondary glaucoma, confirming findings in patients from Northern Europe.

Verified
Journal Article
Open access
PDF file
CSCharlotte Szewczykowski
Charlotte Szewczykowski
CMChristian Mardin
Christian Mardin
MLMarianna Lucio
Marianna Lucio
GWGerd Wallukat
Gerd Wallukat
JHJakob Hoffmanns
Jakob Hoffmanns
Bettina HohbergerBettina Hohberger
Bettina Hohberger
Long COVID (LC) describes the clinical phenotype of symptoms after infection with the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Diagnostic and therapeutic options are limited, as the pathomechanism of LC is elusive. As the number of acute SARS-CoV-2 infections was and is large, LC will be a challenge for the healthcare system. Previous studies revealed an impaired blood flow, the formation of microclots, and autoimmune mechanisms as potential factors in this complex interplay. Since functionally active autoantibodies against G-protein-coupled receptors (GPCR-AAbs) were observed in patients after SARS-CoV-2 infection, this study aimed to correlate the appearance of GPCR-AAbs with capillary microcirculation. The seropositivity of GPCR-AAbs was measured by an established cardiomyocyte bioassay in 42 patients with LC and 6 controls. Retinal microcirculation was measured by OCT–angiography and quantified as macula and peripapillary vessel density (VD) by the Erlangen-Angio Tool. A statistical analysis yielded impaired VD in patients with LC compared to the controls, which was accentuated in female persons. A significant decrease in macula and peripapillary VD for AAbs targeting adrenergic β2-receptor, MAS-receptor angiotensin-II-type-1 receptor, and adrenergic α1-receptor were observed. The present study might suggest that a seropositivity of GPCR-AAbs can be linked to an impaired retinal capillary microcirculation, potentially mirroring the systemic microcirculation with consecutive clinical symptoms.

1 May 2009 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
FHFolkert K. Horn
Folkert K. Horn
CMChristian Y. Mardin
Christian Y. Mardin
RLRobert Lämmer
Robert Lämmer
DBDelia Baleanu
Delia Baleanu
AJAnselm M. Juenemann
Anselm M. Juenemann
RTRalf P. Tornow
Ralf P. Tornow
Purpose. To study the correlation between local perimetric field defects and glaucoma-induced thickness reduction of the nerve layer measured in the peripapillary area with scanning laser polarimetry (SLP) and spectral domain optical coherence tomography (SOCT) and to compare the results with those of a theoretical model.

1 May 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
JWJulia M. Wessel
Julia M. Wessel
FHFolkert K. Horn
Folkert K. Horn
RTRalf P. Tornow
Ralf P. Tornow
MSMatthias Schmid
Matthias Schmid
CMChristian Y. Mardin
Christian Y. Mardin
RLRobert Lämmer
Robert Lämmer
Purpose.: To compare the longitudinal loss of RNFL thickness measurements by SD-OCT in healthy individuals and glaucoma patients with or without progression concerning optic disc morphology. Methods.: A total of 62 eyes, comprising 38 glaucomatous eyes with open angle glaucoma and 24 healthy controls, were included in the study (Erlangen Glaucoma Registry, NTC00494923). All patients were investigated annually over a period of 3 years by Spectralis SD-OCT measuring peripapillary RNFL thickness. By masked comparative analysis of photographs, the eyes were classified into nonprogressive and progressive glaucoma cases. Longitudinal loss of RNFL thickness was compared with morphological changes of optic disc morphology. Results.: Mixed model analysis of annual OCT scans revealed an estimated annual decrease of the RNFL thickness by 2.12 μm in glaucoma eyes with progression, whereas glaucoma eyes without progression in optic disc morphology lost 1.18 μm per year in RNFL thickness (P = 0.002). The rate of change in healthy eyes was 0.60 μm and thereby also significantly lower than in glaucoma eyes with progression (P < 0.001). The intrasession variability of three successive measurements without head repositioning was 1.5 ± 0.7 μm. The loss of mean RNFL thickness exceeded the intrasession variability in 60% of nonprogressive eyes, and in 85% of progressive eyes after 3 years. Conclusions.: Longitudinal measurements of RNFL thickness using SD-OCT show a more pronounced reduction of RNFL thickness in patients with progression compared with patients without progression in glaucomatous optic disc changes. (www.clinicaltrials.gov number, NTC00494923.)