Gert-Jan Allemeersch

Dr. Gert-Jan Allemeersch

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2021 in Frontiers in Aging Neuroscience
Verified
Journal Article
Open access
MWMandy Melissa Jane Wittens
Mandy Melissa Jane Wittens
GAGert-Jan Allemeersch
Gert-Jan Allemeersch
DSDiana Maria Sima
Diana Maria Sima
MNMaarten Naeyaert
Maarten Naeyaert
TVTim Vanderhasselt
Tim Vanderhasselt
SESebastiaan Engelborghs
Sebastiaan Engelborghs
Magnetic Resonance Imaging (MRI) has become part of the clinical routine for diagnosing neurodegenerative disorders. Since acquisitions are performed at multiple centers using multiple imaging systems, detailed analysis of brain volumetry differences between MRI systems and scan-rescan acquisitions can provide valuable information to correct for different MRI scanner effects in multi-center longitudinal studies. To this end, five healthy controls and five patients belonging to various stages of the AD continuum underwent brain MRI acquisitions on three different MRI systems (Philips Achieva dStream 1.5T, Philips Ingenia 3T, and GE Discovery MR750w 3T) with harmonized scan parameters. Each participant underwent two subsequent MRI scans per imaging system, repeated on three different MRI systems within 2 h. Brain volumes computed by icobrain dm (v5.0) were analyzed using absolute and percentual volume differences, Dice similarity (DSC) and intraclass correlation coefficients, and coefficients of variation (CV). Harmonized scans obtained with different scanners of the same manufacturer had a measurement error closer to the intra-scanner performance. The gap between intra- and inter-scanner comparisons grew when comparing scans from different manufacturers. This was observed at image level (image contrast, similarity, and geometry) and translated into a higher variability of automated brain volumetry. Mixed effects modeling revealed a significant effect of scanner type on some brain volumes, and of the scanner combination on DSC. The study concluded a good intra- and inter-scanner reproducibility, as illustrated by an average intra-scanner (inter-scanner) CV below 2% (5%) and an excellent overlap of brain structure segmentation (mean DSC > 0.88).

16 April 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
TVT. Vanderhasselt
T. Vanderhasselt
MNM. Naeyaert
M. Naeyaert
NWN. Watté
N. Watté
GAGert-Jan Allemeersch
Gert-Jan Allemeersch
SRS. Raeymaeckers
S. Raeymaeckers
HRH. Raeymaekers
H. Raeymaekers
BACKGROUND AND PURPOSE: Neonatal MR imaging brain volume measurements can be used as biomarkers for long-term neurodevelopmental outcome, but quantitative volumetric MR imaging data are not usually available during routine radiologic evaluation. In the current study, the feasibility of automated quantitative brain volumetry and image reconstruction via synthetic MR imaging in very preterm infants was investigated. MATERIALS AND METHODS: Conventional and synthetic T1WIs and T2WIs from 111 very preterm infants were acquired at term-equivalent age. Overall image quality and artifacts of the conventional and synthetic images were rated on a 4-point scale. Legibility of anatomic structures and lesion conspicuity were assessed on a binary scale. Synthetic MR volumetry was compared with that generated via MANTiS, which is a neonatal tissue segmentation toolbox based on T2WI. RESULTS: Image quality was good or excellent for most conventional and synthetic images. The 2 methods did not differ significantly regarding image quality or diagnostic performance for focal and cystic WM lesions. Dice similarity coefficients had excellent overlap for intracranial volume (97.3%) and brain parenchymal volume (94.3%), and moderate overlap for CSF (75.6%). Bland-Altman plots demonstrated a small systematic bias in all cases (1.7%–5.9%) CONCLUSIONS: Synthetic T1WI and T2WI sequences may complement or replace conventional images in neonatal imaging, and robust synthetic volumetric results are accessible from a clinical workstation in less than 1 minute. Via the above-described methods, volume assessments could be routinely used in daily clinical practice.

21 January 2020 in Polish Journal of Radiology
Verified
Journal Article
Open access
Hannes DevosHannes Devos
Hannes Devos
LGLode Goethals
Lode Goethals
DBDries Belsack
Dries Belsack
YBYannick De Brucker
Yannick De Brucker
GAGert-Jan Allemeersch
Gert-Jan Allemeersch
JMJohan de Mey
Johan de Mey
Intra-abdominal fat is abundantly present in both the peritoneum and retroperitoneum. Fat necrosis or inflammation are common findings in abdominal imaging. The most common pathologies that we encounter are epiploic appenda­gitis, omental infarction, mesenteric panniculitis, and encapsulated fat necrosis. Less common entities that can occur are pancreatic saponification, heterotopic mesenteric ossification, and pseudolipoma of the capsule of Glisson. These entities can mimic more urgent pathologies such as appendicitis, diverticulitis, or malignancies.

19 January 2024 in Neuroradiology
Verified
Journal Article
Open access
PDF file
MWMandy M. J. Wittens
Mandy M. J. Wittens
GAGert-Jan Allemeersch
Gert-Jan Allemeersch
DSDiana Maria Sima
Diana Maria Sima
TVTim Vanderhasselt
Tim Vanderhasselt
SRSteven Raeymaeckers
Steven Raeymaeckers
SESebastiaan Engelborghs
Sebastiaan Engelborghs
Purpose: To assess the performance of the inferior lateral ventricle (ILV) to hippocampal (Hip) volume ratio on brain MRI, for Alzheimer’s disease (AD) diagnostics, comparing it to individual automated ILV and hippocampal volumes, and visual medial temporal lobe atrophy (MTA) consensus ratings. Methods: One-hundred-twelve subjects (mean age ± SD, 66.85 ± 13.64 years) with varying degrees of cognitive decline underwent MRI using a Philips Ingenia 3T. The MTA scale by Scheltens, rated on coronal 3D T1-weighted images, was determined by three experienced radiologists, blinded to diagnosis and sex. Automated volumetry was computed by icobrain dm (v. 5.10) for total, left, right hippocampal, and ILV volumes. The ILV/Hip ratio, defined as the percentage ratio between ILV and hippocampal volumes, was calculated and compared against a normative reference population (n = 1903). Inter-rater agreement, association, classification accuracy, and clinical interpretability on patient level were reported. Results: Visual MTA scores showed excellent inter-rater agreement. Ordinal logistic regression and correlation analyses demonstrated robust associations between automated brain segmentations and visual MTA ratings, with the ILV/Hip ratio consistently outperforming individual hippocampal and ILV volumes. Pairwise classification accuracy showed good performance without statistically significant differences between the ILV/Hip ratio and visual MTA across disease stages, indicating potential interchangeability. Comparison to the normative population and clinical interpretability assessments showed commensurability in classifying MTA “severity” between visual MTA and ILV/Hip ratio measurements. Conclusion: The ILV/Hip ratio shows the highest correlation to visual MTA, in comparison to automated individual ILV and hippocampal volumes, offering standardized measures for diagnostic support in different stages of cognitive decline.

4 January 2018
Verified
Journal Article
Open access
PDF file
GAGert-Jan Allemeersch
Gert-Jan Allemeersch
CMCaroline Muylaert
Caroline Muylaert
KNKoenraad Nieboer
Koenraad Nieboer
We report the case of a 41-year-old male with traumatic coronary artery dissection after a high-speed motor vehicle collision. Computed tomography imaging revealed multiple intracranial subdural and subarachnoid bleedings, a skull base fracture and multiple bilateral rib fractures. There was no pericardial hemorrhage, haemothorax or pneumothorax. No intra-abdominal lesions were found. A 12-lead electrocardiogram on arrival showed an acute myocardial infarction. Emergency angiography showed complete dissection of the right coronary artery without reflow after placement of 6 coronary stents. The patient passed away the day after. In retrospective, the right coronary dissection was visible on the trauma CT-scan.

20 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Joke TemmermanJoke Temmerman
Joke Temmerman
FVFloris Van Der Veken
Floris Van Der Veken
SESebastiaan Engelborghs
Sebastiaan Engelborghs
KGKaat Guldolf
Kaat Guldolf
GNGuy Nagels
Guy Nagels
MDMiguel D’haeseleer
Miguel D’haeseleer
Multiple sclerosis (MS) is a chronic inflammatory demyelinating and degenerative disorder of the central nervous system. Accelerated brain volume loss (BVL) has emerged as a promising magnetic resonance imaging marker (MRI) of neurodegeneration, correlating with present and future clinical disability. We have systematically selected MS patients fulfilling ‘no evidence of disease activity-3′ (NEDA-3) criteria under high-efficacy disease-modifying treatment (DMT) from the database of two Belgian MS centers. BVL between both MRI scans demarcating the NEDA-3 period was assessed and compared with a group of prospectively recruited healthy volunteers who were matched for age and gender. Annualized whole brain volume percentage change was similar between 29 MS patients achieving NEDA-3 and 24 healthy controls (−0.25 ± 0.49 versus −0.24 ± 0.20, p = 0.9992; median follow-up 21 versus 33 months; respectively). In contrast, we found a mean BVL increase of 72%, as compared with the former, in a second control group of MS patients (n = 21) whom had been excluded from the NEDA-3 group due to disease activity (p = 0.1371). Our results suggest that neurodegeneration in MS can slow down to the rate of normal aging once inflammatory disease activity has been extinguished and advocate for an early introduction of high-efficacy DMT to reduce the risk of future clinical disability.