The energy transition, originating in the limitation of fossil resources and greenhouse gas (GHG) emission reduction, is the basis of many studies on renewable energies in different industrial applications. The diffusion absorption refrigeration machines are very promising insofar as they allow the use of renewable resources (solar, geothermal, waste gas, etc.). This technology is often considered an alternative to vapor compression systems in cooling and refrigeration applications. This paper aims to overview the thermal mechanisms related to modeling system energy sources and highlight the primary methodologies and techniques used. We study and analyze the technology’s current challenges and future directions and, finally, identify the gaps in the existing models to pave the way for future research. The paper also gives a classification of absorption refrigeration systems (ARS) to position and limit the scope of the study. The paper will help researchers who approach the various aspects to have a global synthetic analysis of the mechanisms characterizing the modeling of energy sources of absorption refrigeration machines.
The global concern regarding the environmental repercussions of refrigerants has escalated due to their adverse effects. These substances deplete the ozone layer and intensify the greenhouse effect. International agreements such as the Montreal and Kyoto Protocols and COP21 have imposed restrictions on refrigerants with high global warming potential (GWP) to address these issues. This study aims to explore the feasibility, energy efficiency, and environmental impact of utilizing the HFO (hydrofluoric-olefin) refrigerant R1234ze as a substitute for HFCs (hydrofluoric-carbon) (R134a, R407C, and R410A) and HCFCs (R22) in air-cooled vapor compression refrigeration and air conditioning systems. To determine their effectiveness, we evaluate the energy performance of various refrigerant operating cycles across a wide range of ambient and evaporating temperatures. Additionally, we conduct environmental impact analyses based on the total equivalent warming impact (TEWI) parameter calculated for commercially available chillers that utilize the fluids mentioned above. Our findings indicate that vapor compression chilled water systems employing R1234ze exhibit the highest performance coefficient and the lowest annual TEWI.
The Raglan mining site in northern Quebec relies on diesel for electricity and heat generation, resulting in annual emissions of 105,500 tons of CO2 equivalent. This study investigates the feasibility of decarbonizing the site’s power generation system by integrating a renewable energy network of wind turbines and a pumped hydro storage plant (PHSP). It uniquely integrates PHSP modeling with a dynamic analysis of variable wind speeds and extreme climatic conditions, providing a novel perspective on the feasibility of renewable energy systems in remote northern regions. MATLAB R2024b-based simulations assessed the hybrid system’s technical and economic performance. The proposed system, incorporating a wind farm and PHSP, reduces greenhouse gas (GHG) emissions by 50%, avoiding 68,500 tons of CO2 equivalent annually, and lowers diesel consumption significantly. The total investment costs are estimated at 2080 CAD/kW for the wind farm and 3720 CAD/kW for the PHSP, with 17.3 CAD/MWh and 72.5 CAD/kW-year operational costs, respectively. The study demonstrates a renewable energy share of 52.2% in the energy mix, with a payback period of approximately 11 years and substantial long-term cost savings. These findings highlight the potential of hybrid renewable energy systems to decarbonize remote, off-grid industrial operations and provide a scalable framework for similar projects globally.
The dwindling and scarcity of fossil energy sources is the basis of the energy transition, where renewable resources are increasingly valued. The purpose of the cogeneration system studied in this article is to recover the residual heat from the gases coming out of the chimneys of the cement kilns, to produce at the same time the electricity and the heat required for offices and residential houses of cement workers. Cement kilns are reputed to be energy-intensive, generating excessive heat losses. These heat losses are found mainly in the conduction–convective and radiative modes, representing about 26% of the overall heat input to the system. Nevertheless, the gases at the chimney outlet can still have temperatures between 250 and 350 °C, which presents a non-negligible potential for a cogeneration system. This study compares the thermal performance of different cogeneration plant configurations (KCA, KCB, and KCC systems) using the Kalina cycle to determine the best one. Several assumptions were made to reduce the complexity of the model. MATLAB and Excel software were used to solve the system of equations. After extensive analysis of the results, the KCA system showed the best performance, compared to the KCB and KCC systems, with a thermal efficiency of 22.15%, an exergy efficiency of 45.12%, and a net electrical capacity of 2565.03 kWe. Model sensitivity to concentration, temperature, and pressure variations also gave the KCA system the best-performing system. Evaluation of the excess heat flux removed from the process yields values of 7368.20 kW, 7421.86 kW, and 8094.15 kW for the KCA, KCB, and KCC systems. The results of this article serve as a decision support tool for installing the cogeneration system via the Kalina cycle in cement installations.