Stylianos Chatzidakis

Dr. Stylianos Chatzidakis

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SCStylianos Chatzidakis
Stylianos Chatzidakis
SCS. Chrysikopoulou
S. Chrysikopoulou
LTL.H. Tsoukalas
L.H. Tsoukalas

18 October 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
SCStylianos Chatzidakis
Stylianos Chatzidakis
CCChan K. Choi
Chan K. Choi
Lefteri H. TsoukalasLefteri H. Tsoukalas
Lefteri H. Tsoukalas
Cosmic ray muons passing through matter lose energy from inelastic collisions with electrons and are deflected from nuclei due to multiple Coulomb scattering. The strong dependence of scattering on atomic number Z and the recent developments on position sensitive muon detectors indicate that multiple Coulomb scattering could be an excellent candidate for spent nuclear fuel imaging. Muons present significant advantages over existing monitoring and imaging techniques and can play a central role in monitoring nuclear waste and spent nuclear fuel stored in dense well shielded containers. The main purpose of this paper is to investigate the applicability of multiple Coulomb scattering for imaging of spent nuclear fuel dry casks stored within vertical and horizontal commercial storage dry casks. Calculations of muon scattering were performed for various scenarios, including vertical and horizontal fully loaded dry casks, half loaded dry casks, dry casks with one row of fuel assemblies missing, dry casks with one fuel assembly missing and empty dry casks. Various detector sizes (1.2 m ×1.2 m, 2.4 m ×2.4 m and 3.6 m ×3.6 m) and number of muons (10 5 , 5 · 10 5 , 10 6 and 10 7 ) were used to assess the effect on image resolution. The Point-of-Closest-Approach (PoCA) algorithm was used for the reconstruction of the stored contents. The results demonstrate that multiple Coulomb scattering can be used to successfully reconstruct the dry cask contents and allow identification of all scenarios with the exception of one fuel assembly missing. In this case, an indication exists that a fuel assembly is not present; however, the resolution of the imaging algorithm was not enough to identify exact location.

1 August 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SCStylianos Chatzidakis
Stylianos Chatzidakis
CCC.K. Choi
C.K. Choi
LTL.H. Tsoukalas
L.H. Tsoukalas

1 December 2014 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
Ali HainounAli Hainoun
Ali Hainoun
ADA. Doval
A. Doval
PUP. Umbehaun
P. Umbehaun
SCStylianos Chatzidakis
Stylianos Chatzidakis
NGN. Ghazi
N. Ghazi
ASA. Shokr
A. Shokr

28 March 2018 in Journal of Applied Physics
Verified
Journal Article
Closed access
SCStylianos Chatzidakis
Stylianos Chatzidakis
ZLZhengzhi Liu
Zhengzhi Liu
JHJason P. Hayward
Jason P. Hayward
JSJohn M. Scaglione
John M. Scaglione
This work presents a generalized muon trajectory estimation algorithm to estimate the path of a muon in either uniform or nonuniform media. The use of cosmic ray muons in nuclear nonproliferation and safeguard verification applications has recently gained attention due to the non-intrusive and passive nature of the inspection, penetrating capabilities, as well as recent advances in detectors that measure position and direction of the individual muons before and after traversing the imaged object. However, muon image reconstruction techniques are limited in resolution due to low muon flux and the effects of multiple Coulomb scattering (MCS). Current reconstruction algorithms, e.g., point of closest approach (PoCA) or straight-line path (SLP), rely on overly simple assumptions for muon path estimation through the imaged object. For robust muon tomography, efficient and flexible physics-based algorithms are needed to model the MCS process and accurately estimate the most probable trajectory of a muon as it traverses an object. In the present work, the use of a Bayesian framework and a Gaussian approximation of MCS is explored for estimation of the most likely path of a cosmic ray muon traversing uniform or nonuniform media and undergoing MCS. The algorithm's precision is compared to Monte Carlo simulated muon trajectories. It was found that the algorithm is expected to be able to predict muon tracks to less than 1.5 mm root mean square (RMS) for 0.5 GeV muons and 0.25 mm RMS for 3 GeV muons, a 50% improvement compared to SLP and 15% improvement when compared to PoCA. Further, a 30% increase in useful muon flux was observed relative to PoCA. Muon track prediction improved for higher muon energies or smaller penetration depth where energy loss is not significant. The effect of energy loss due to ionization is investigated, and a linear energy loss relation that is easy to use is proposed.

13 September 2018 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
ZLZhengzhi Liu
Zhengzhi Liu
SCStylianos Chatzidakis
Stylianos Chatzidakis
JSJohn M. Scaglione
John M. Scaglione
CLCan Liao
Can Liao
HYHaori Yang
Haori Yang
JHJason P. Hayward
Jason P. Hayward
Cosmic ray muon-computed tomography ( $\mu$ CT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo scanning, and volcano imaging. The strong scattering dependence of muons on atomic number Z in combination with high penetration range could offer a significant advantage over existing techniques when dense, shielded containers must be imaged. However, $\mu$ CT reconstruction using conventional filtered back-projection is limited due to the overly simple assumptions that do not consider the curved path caused by multiple Coulomb scattering prompting the need for more sophisticated approaches to be developed. In this paper, we argue that the use of improved muon tracing and scattering angle projection algorithms as well as an algebraic reconstruction technique should produce muon tomographic images with improved quality–or require fewer muons to produce the same image quality–compared to the case where conventional methods are used. We report on the development and assessment of three novel muon tracing methods and two scattering angle projection methods for $\mu$ CT. Simulated dry storage casks with single and partial missing fuel assemblies were used as numerical examples to assess and compare the proposed methods. The reconstructed images showed an expected improvement in image quality when compared with conventional techniques, even without muon momentum information, which should lead to improved detection capability, even for partial defects.