Güray Doğan

Dr. Güray Doğan


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2010 in Indoor Air
Verified
Journal Article
Closed access
PDF file
BPB. Pekey
B. Pekey
ZBZehra Bozkurt
Zehra Bozkurt
HPH. Pekey
H. Pekey
GDGüray Doğan
Güray Doğan
AZA. Zararsız
A. Zararsız
GTG. Tuncel
G. Tuncel
This study presents indoor/outdoor PM2.5 and PM10 concentrations measured during winter and summer in 15 homes in Kocaeli, which is one of the most industrialized areas in Turkey. Indoor and outdoor PM2.5 and PM10 mass concentrations and elemental composition were determined using an X-ray fluorescence spectrometer. Quantitative information was obtained on mass concentrations and other characteristics such as seasonal variation, indoor/outdoor (I/O) ratio, PM2.5/PM10 ratio, correlations and sources. Average indoor and outdoor PM2.5 concentrations were 29.8 and 23.5 microg/m(3) for the summer period, and 24.4 and 21.8 microg/m(3) for the winter period, respectively. Average indoor and outdoor PM10 concentrations were 45.5 and 59.9 microg/m(3) for the summer period, and 56.9 and 102.3 microg/m(3) for the winter period, respectively. A varimax rotated factor analysis (FA) was performed separately on indoor and outdoor datasets in an effort to identify possible heavy metal sources of PM2.5 and PM10 particle fractions. FA of outdoor data produced source categories comprising polluted soil, industry, motor vehicles, and fossil fuel combustion for both PM fractions, while source categories determined for indoor data for both PM2.5 and PM10 comprised industry, polluted soil, motor vehicles, and smoking, with an additional source category of cooking activities detected for the PM2.5 fraction. Practical Implications In buildings close to industrial areas or traffic arteries, outdoor sources may have an important effect on indoor air pollution. Therefore, indoor and outdoor investigations should be conducted simultaneously to assess the relationship between indoor and outdoor pollution. This study presents the simultaneous measurement of PM fractions (PM2.5 and PM10) and their elemental compositions to determine the sources of respirable PM and the heavy metals bound to these particles in indoor air. Factor analysis of indoor data indicated that the contribution of outdoor pollutant sources to indoor pollution was about 70%, making these sources the most significant for indoor heavy metal pollution, wheras other sources of indoor pollution included smoking and cooking activities.

1 February 2015 in Atmospheric Environment
Verified
Journal Article
Open access
MCMihriban Yılmaz Civan
Mihriban Yılmaz Civan
TETolga Elbir
Tolga Elbir
RSRemzi Seyfioglu
Remzi Seyfioglu
ÖKÖznur Oğuz Kuntasal
Öznur Oğuz Kuntasal
ABAbdurrahman Bayram
Abdurrahman Bayram
GTGürdal Tuncel
Gürdal Tuncel
Ambient concentrations of volatile organic compounds (VOCs), nitrogen dioxide (NO2), sulphur dioxide (SO2) and ground-level ozone (O3) were measured at 55 locations around a densely populated industrial zone, hosting a petrochemical complex (Petkim), a petroleum refinery (Tupras), ship-dismantling facilities, several iron and steel plants, and a gas-fired power plant. Five passive sampling campaigns were performed covering summer and winter seasons of 2005 and 2007. Elevated concentrations of VOCs, NO2 and SO2 around the refinery, petrochemical complex and roads indicated that industrial activities and vehicular emissions are the main sources of these pollutants in the region. Ozone concentrations were low at the industrial zone and settlement areas, but high in rural stations downwind from these sources due to NO distillation. The United States Environmental Protection Agency's positive matrix factorization receptor model (EPA PMF) was employed to apportion ambient concentrations of VOCs into six factors, which were associated with emissions sources. Traffic was found to be highest contributor to measured ∑VOCs concentrations, followed by the Petkim and Tupras.Median cancer risk due to benzene inhalation calculated using a Monte Carlo simulation was approximately 4 per-one-million population, which exceeded the U.S. EPA benchmark of 1 per one million. Petkim, Tupras and traffic emissions were the major sources of cancer risk due to benzene inhalation in the Aliaga airshed. Relative contributions of these two source groups changes significantly from one location to another, demonstrating the limitation of determining source contributions and calculating health risk using data from one or two permanent stations in an industrial area.TUBITAK (104Y276

1 March 2018 in Atmospheric Pollution Research
Verified
Journal Article
Closed access
SYSema Yurdakul
Sema Yurdakul
MCMihriban Civan
Mihriban Civan
ÖKÖznur Kuntasal
Öznur Kuntasal
GDGüray Doğan
Güray Doğan
HPHakan Pekey
Hakan Pekey
GTGürdal Tuncel
Gürdal Tuncel


27 August 2015 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
ZBZehra Bozkurt
Zehra Bozkurt
GDGüray Doğan
Güray Doğan
DADemet Arslanbaş
Demet Arslanbaş
BPBeyhan Pekey
Beyhan Pekey
HPHakan Pekey
Hakan Pekey
GTGürdal Tuncel
Gürdal Tuncel

1 November 2005 in Atmospheric Environment
Verified
Journal Article
Closed access
GGGülen Güllü
Gülen Güllü
GDGüray Doğan
Güray Doğan
GTGürdal Tuncel
Gürdal Tuncel