Venugopal Arumuru

Dr. Venugopal Arumuru


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
VAVenugopal Arumuru
Venugopal Arumuru
JPJangyadatta Pasa
Jangyadatta Pasa
SSSidhartha Sankar Samantaray
Sidhartha Sankar Samantaray
In the present work, we propose and demonstrate a simple experimental visualization to simulate sneezing by maintaining dynamic similarity to actual sneezing. A pulsed jet with Reynolds number Re = 30 000 is created using compressed air and a solenoid valve. Tracer particles are introduced in the flow to capture the emulated turbulent jet formed due to a sneeze. The visualization is accomplished using a camera and laser illumination. It is observed that a typical sneeze can travel up to 25 ft in ∼22 s in a quiescent environment. This highlights that the present widely accepted safe distance of 6 ft is highly underestimated, especially under the act of a sneeze. Our study demonstrates that a three-layer homemade mask is just adequate to impede the penetration of fine-sized particles, which may cause the spreading of the infectious pathogen responsible for COVID-19. However, a surgical mask cannot block the sneeze, and the sneeze particle can travel up to 2.5 ft. We strongly recommend using at least a three-layer homemade mask with a social distancing of 6 ft to combat the transmission of COVID-19 virus. In offices, we recommend the use of face masks and shields to prevent the spreading of droplets carrying the infectious pathogen. Interestingly, an N-95 mask blocks the sneeze in the forward direction; however, the leakage from the sides and top spreads the sneeze in the backward direction up to 2 ft. We strongly recommend using the elbow or hands to prevent droplet leakage even after wearing a mask during sneezing and coughing.

15 March 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HGHarsh Gupta
Harsh Gupta
VAVenugopal Arumuru
Venugopal Arumuru
RJRajan Jha
Rajan Jha
Optical fibers have been extensively employed for the development of sensors due to their compact size, immunity to electromagnetic interference, high sensitivity, and multiplexing capability. This work discusses various optical fiber flow meters developed in the past, which have great potential for industrial applications. The optical fiber flow sensors are classified on the basis of modulation in property of light viz. intensity, wavelength, frequency, or phase. This paper also includes a comparison of flowmeters, in terms of sensitivity and measurement range, utilizing different modulation techniques for operation apart from some limitations and future outlook.

1 June 2021 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
DMDnyanesh Mirikar
Dnyanesh Mirikar
SPSilambarasan Palanivel
Silambarasan Palanivel
VAVenugopal Arumuru
Venugopal Arumuru
The second and third waves of coronavirus disease-2019 (COVID-19) pandemic have hit the world. Even after more than a year, the economy is yet to return to a semblance of normality. The conference/meeting room is one of the critical sections of offices that might be difficult not to use. This study analyzes the distribution of the virus-laden droplets expelled by coughing inside a conference room, the effect of ventilation rates, and their positioning. The efficacy of masks is studied to get quantitative information regarding the residence time of the droplets. The effects of evaporation, turbulent dispersion, and external forces have been considered for calculating the droplets' trajectories. We have analyzed six cases, of which two are with masks. Change in the ventilation rate from four air changes per hour (ACH) to eight resulted in a 9 % increment in the number of droplets entrained in the outlet vent, while their average residence time was reduced by ∼   8   s . The shift in the vents' location has significantly altered droplets' distribution inside a conference room. It results in ∼   1.5 % of the injected droplets reaching persons sitting across the table, and a similar indoor environment is not recommended. Wearing a mask in the case of eight ACH has presented the best scenario out of the six cases, with a 6.5 % improvement in the number of droplets entrained in the outlet vent and a 9   s decrease in their average residence time compared to the case without a mask. No droplets have reached persons sitting across the table when the infected person is wearing the mask, which follows that a social distancing of 6   ft with a mask is adequate in indoor environments.

1 April 2021 in AIP Advances
Verified
Journal Article
Open access
PDF file
VAVenugopal Arumuru
Venugopal Arumuru
JPJangyadatta Pasa
Jangyadatta Pasa
SSSidhartha Sankar Samantaray
Sidhartha Sankar Samantaray
VVVaibhavsingh Surendrasingh Varma
Vaibhavsingh Surendrasingh Varma
With the outbreak of COVID-19 in many countries, public awareness related to the droplet mode of virus transmission is well documented and communicated. With a large spike in COVID-19 positive cases and the mortality rate, most of the general public are following preventive measures such as wearing masks, maintaining social distancing, and frequent hand washing. However, recently, it has been reported that the virus may also transmit through aerosolized particles of diameter <10 µm. The majority of the past research focuses on understanding droplet generation and transport through the most violent spasmodic expiration: coughing and sneezing. However, “breathing,” the most common phenomenon, is scarcely studied as a virus transmission source. In the present study, we report an experimental visualization of the droplet’s transport through breathing to quantify the reach of a typical breath for various exhale to inhale ratios. The efficacy of various standard (surgical, five-layered, and N95) and non-standard (homemade) protective measures such as face masks and face shields is also evaluated. An exhaled breath at E:I = 1:1 can travel up to 4 ft in 5 s; however, this reach reduces to 3 ft for E:I = 1:2. Two-layer homemade and commercial cotton masks are unable to completely impede the leakage of the droplet in the forward direction. A combination of a two-layer mask and face shield is also not effective in preventing the leakage and diffusion of the droplets. The surgical mask alone is not recommended during normal conversations as the leakage of the droplets is noticeable. A commercial N95 mask completely impedes the leakage of the droplets in the forward direction. However, the leakage of the droplets from the gaps between the mask and the nose is observed to be significant. A commercial five-layered mask is observed to be the most effective preservative measure with minimum leakage of the droplets.

29 July 2022 in International Journal of Mechanical Sciences
Verified
Journal Article
Closed access
SPSamarendra Panda
Samarendra Panda
TGTrushar B. Gohil
Trushar B. Gohil
VAVenugopal Arumuru
Venugopal Arumuru

1 June 2022 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
JPJangyadatta Pasa
Jangyadatta Pasa
SPSamarendra Panda
Samarendra Panda
VAVenugopal Arumuru
Venugopal Arumuru
A computational study is presented to characterize the flow behavior of independently controlled multiple synthetic jet actuators (SJA). For fixed geometric configuration and Reynolds number (Re ) 300 , the influence of Strouhal number (St=0.028–0.172 ) and phase difference (∅=0°–180° ) between the actuators on the evolution, and interaction of the vortices are highlighted. Directivity plots are employed to illustrate the effect of ∅ on the vectoring behavior of a synthetic jet array (SJ array). It has been observed that a high jet vectoring angle (β ) is achieved while operating the SJ array at low St . The vectoring angle seems to be independent of ∅ for the low and high St . However, for an intermediate St=0.086 , the vectoring angle varies with the ∅ . The phase averaged vorticity contour for St=0.028 reveals that the evolution of the anti-clockwise vortex from the leading actuator (SJA1) decides the vectoring of the jet. By contrast, for higher Sts (0.115 and 0.13 ), the remnant vortices play a significant role in vectoring the jets toward the leading actuator. Based on the cross-stream distribution of time-averaged streamwise velocity, three distinct flow regimes are characterized: near-field, intermediate-field, and far-field. The strength of the jet is quantified by the downstream distribution of the jet momentum flux. Proper evolution of the vortices results in the enhancement of the jet momentum flux. It is recommended to operate the SJ array at an intermediate St (0.086 ) to vary the jet vectoring angle with phase differences as well as to achieve maximum jet momentum flux.