Alfio Bronco

Alfio Bronco


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
NENilde Eronia
Nilde Eronia
TMTommaso Mauri
Tommaso Mauri
EMElisabetta Maffezzini
Elisabetta Maffezzini
SGStefano Gatti
Stefano Gatti
ABAlfio Bronco
Alfio Bronco
GBGiacomo Bellani
Giacomo Bellani
Positive end-expiratory pressure (PEEP) is a key element of mechanical ventilation. It should optimize recruitment, without causing excessive overdistension, but controversy exists on the best method to set it. The purpose of the study was to test the feasibility of setting PEEP with electrical impedance tomography in order to prevent lung de-recruitment following a recruitment maneuver. We enrolled 16 patients undergoing mechanical ventilation with PaO2/FiO2 <300 mmHg. In all patients, under constant tidal volume (6–8 ml/kg) PEEP was set based on the PEEP/FiO2 table proposed by the ARDS network (PEEPARDSnet). We performed a recruitment maneuver and monitored the end-expiratory lung impedance (EELI) over 10 min. If the EELI signal decreased during this period, the recruitment maneuver was repeated and PEEP increased by 2 cmH2O. This procedure was repeated until the EELI maintained a stability over time (PEEPEIT). The procedure was feasible in 87% patients. PEEPEIT was higher than PEEPARDSnet (13 ± 3 vs. 9 ± 2 cmH2O, p < 0.001). PaO2/FiO2 improved during PEEPEIT and driving pressure decreased. Recruited volume correlated with the decrease in driving pressure but not with oxygenation improvement. Finally, regional alveolar hyperdistention and collapse was reduced in dependent lung layers and increased in non-dependent lung layers. In hypoxemic patients, a PEEP selection strategy aimed at stabilizing alveolar recruitment guided by EIT at the bedside was feasible and safe. This strategy led, in comparison with the ARDSnet table, to higher PEEP, improved oxygenation and reduced driving pressure, allowing to estimate the relative weight of overdistension and recruitment.

1 January 2020 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
ACAndrea Coppadoro
Andrea Coppadoro
AGAlice Grassi
Alice Grassi
CGCecilia Giovannoni
Cecilia Giovannoni
FRFrancesca Rabboni
Francesca Rabboni
NENilde Eronia
Nilde Eronia
GBGiacomo Bellani
Giacomo Bellani
Pendelluft, the movement of gas within different lung regions, is present in animal models of assisted mechanical ventilation and associated with lung overstretching. Due to rebreathing of CO2 as compared to fresh gas, pendelluft might reduce ventilatory efficiency possibly exacerbating patient’s respiratory workload during weaning. Our aim was to measure pendelluft by electrical impedance tomography (EIT) in patients who failed a spontaneous breathing trial (SBT). This is an observational study conducted in a general intensive care unit of a tertiary-level teaching hospital. EIT signal was recorded in 20 patients while pressure support (PS) ventilation was progressively reduced from clinical level (baseline) to 2 cmH2O, as in an SBT; four ventral-to-dorsal lung regions of interest were identified for pendelluft measurement. A regional gas movement (> 6 mL) occurring in a direction opposite to the global EIT signal was considered diagnostic for high pendelluft. Eight patients out of 20 (40%) were classified as high-pendelluft; baseline clinical characteristics did not differ between high- and low-pendelluft patients. At PS reduction, pendelluft and EtCO2 increased more in the high-pendelluft group (p < .001 and .011, respectively). The volume of gas subject to pendelluft moved almost completely from the ventral towards the dorsal lung regions, while the opposite movement was minimal (16.3 [10:32.8] vs. 0 [0:1.8] mL, p = .001). In a subgroup of patients, increased pendelluft volumes positively correlated with markers of respiratory distress such as increased respiratory rate, p0.1, and EtCO2. Occult pendelluft can be measured by EIT, and is frequently present in patients failing an SBT. When present, pendelluft increases with the reduction of ventilator support and is associated with increased EtCO2, suggesting a reduction of the ability to eliminate CO2.

16 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MPMICHELA DI PIERRO
MICHELA DI PIERRO
MGMarco Giani
Marco Giani
ABAlfio Bronco
Alfio Bronco
FLFrancesca Maria Lembo
Francesca Maria Lembo
RRRoberto Rona
Roberto Rona
GFGiuseppe Foti
Giuseppe Foti
Background: The interest in protective ventilation strategies and individualized approaches for patients with severe illness on veno venous extracorporeal support has increased in recent years. Wide heterogeneity exists among patients with COVID-19 related acute respiratory distress syndrome (C-ARDS) and ARDS from other etiologies (NC-ARDS). EIT is a useful tool for the accurate analysis of regional lung volume distribution and allows for a tailored ventilatory setting. The aim of this work is to retrospectively describe the results of EIT assessments performed in patients C-ARDS and NC-ARDS undergoing V-V ECMO support. Methods: A clinical EIT-guided decremental PEEP trail was conducted for all patients included in the study and mechanically ventilated. Results: 12 patients with C-ARDS and 12 patients with NC-ARDS were included in the study for a total of 13 and 18 EIT evaluations, respectively. No significant differences in arterial blood gas, respiratory parameters, and regional ventilation before and after the EIT exam were recorded. The subset of patients with NC-ARDS whose EIT exam led to PEEP modification was characterized by a lower baseline compliance compared with the C-ARDS group: 18 (16–28) vs. 27 (24–30) (p = 0.04). Overdistension significantly increased at higher steps only for the NC-ARDS group. A higher percentage of overdistension was described in patients with NC-ARDS when compared with patients with C-ARDS. Conclusions: EIT is feasible in patients with COVID-19-associated ARDS on veno-venous extracorporeal support and may help in tailoring the PEEP setting. Overall, severe COVID-19-related ARDS presents respiratory characteristics similar to severe “classical” NC-ARDS. However, C-ARDS is associated with a lower risk of overdistension at a higher PEEP level compared with NC-ARDS.

1 January 2015 in Annals of Intensive Care
Verified
Journal Article
Open access
PDF file
ACAndrea Coppadoro
Andrea Coppadoro
GBGiacomo Bellani
Giacomo Bellani
ABAlfio Bronco
Alfio Bronco
Alberto LucchiniAlberto Lucchini
Alberto Lucchini
SBSimone Bramati
Simone Bramati
APAntonio Pesenti
Antonio Pesenti
Early after intubation, a layer of biofilm covers the inner lumen of the endotracheal tube (ETT). Cleaning the ETT might prevent airways colonization by pathogens, reduce resistance to airflow, and decrease sudden ETT obstruction. We investigated the effectiveness of a cleaning closed suction system in maintaining the endotracheal tube free from secretions. We conducted a single center, randomized controlled trial, in the general intensive care unit of a tertiary-level university hospital. We enrolled 40 adult critically ill patients expected to remain intubated for more than 48 h, within 24 h from intubation. Patients were randomized to receive three ETT cleaning maneuvers/day using a novel device (Airway Medix Closed Suction System™, cleaning group) or to standard care (no ETT cleaning, standard closed suction, control group). After extubation, the amount of secretions in the ETTs was measured by micro-computed tomography. The volume of secretions in the ETTs from the cleaning group was lower than controls (0.081 [0.021–0.306] vs. 0.568 [0.162–0.756] mL, p = 0.001), corresponding to a cross-sectional area reduction six times lower (1[0–3] vs. 6 [2–10] %, p = 0.001). In a subset of 16 patients, the resistance to airflow tended to be lower after 1 day of treatment (p = 0.063) and was lower after 2 days (0.024), while no difference was present at enrollment (p = 0.922). ETT colonization did not differ between the two groups. The use of a novel cleaning closed suction system proved to be effective in reducing secretions present in the ETT after extubation, possibly reducing resistance to airflow during intubation. Trial registration: clinicaltrials.gov NCT01912105

28 March 2014 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
ACAndrea Coppadoro
Andrea Coppadoro
GBGiacomo Bellani
Giacomo Bellani
ABAlfio Bronco
Alfio Bronco
RBRoberto Borsa
Roberto Borsa
Alberto LucchiniAlberto Lucchini
Alberto Lucchini
APAntonio Pesenti
Antonio Pesenti
Biofilm accumulates within the endotracheal tube (ETT) early after intubation. Contaminated secretions in the ETT are associated with increased risk for microbial dissemination in the distal airways and increased resistance to airflow. We evaluated the effectiveness of micro computed tomography (MicroCT) for the quantification of ETT inner volume reduction in critically ill patients.