Reliable and complete data held in disaster databases are imperative to inform effective disaster preparedness and mitigation policies. Nonetheless, disaster databases are highly prone to missingness. In this article, we conduct a missing data diagnosis of the widely-cited, global disaster database, the Emergency Events Database (EM-DAT) to identify the extent and potential determinants of missing data within EM-DAT. In addition, through a review of prominent empirical literature, we contextualise how missing data within EM-DAT has been handled previously. A large proportion of missing data was identified for disasters attributed to natural hazards occurring between 1990 and 2020, particularly on the economic losses. The year the disaster occurred, income-classification of the affected country and disaster type were all significant predictors of missingness for key human and economic loss variables. Accordingly, data are unlikely to be missing completely at random. Advanced statistical methods to handle missing data are thus warranted when analysing disaster data to minimise the risk of biasing statistical inferences and to ensure global disaster data can be trusted.
Objectives To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. Design A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. Setting 18 trauma centres in the United Kingdom. Participants 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. Interventions Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. Main outcome measures Primary outcome measure: validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient’s experience of pain and disability to give a score out of 100. Secondary outcomes: disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. Results The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was −1.3, 95% confidence interval −4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. Conclusions Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. Trial registration Current Controlled Trials ISCRTN 31379280. UKCRN 8956.