Yongheng Yang

Prof. Dr. Yongheng Yang

Department of Energy Technology, Aalborg University, 9220 Aalborg, Denmark
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2017 in Proceedings of the IEEE
Verified
Journal Article
Open access
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Yongheng YangYongheng Yang
Yongheng Yang
DYDongsheng Yang
Dongsheng Yang
XWXiongfei Wang
Xiongfei Wang
Continuously expanding deployments of distributed power-generation systems (DPGSs) are transforming the conventional centralized power grid into a mixed distributed electrical network. The modern power grid requires flexible energy utilization but presents challenges in the case of a high penetration degree of renewable energy, among which wind and solar photovoltaics are typical sources. The integration level of the DPGS into the grid plays a critical role in developing sustainable and resilient power systems, especially with highly intermittent renewable energy resources. To address the challenging issues and, more importantly, to leverage the energy generation, stringent demands from both utility operators and consumers have been imposed on the DPGS. Furthermore, as the core of energy conversion, numerous power electronic converters employing advanced control techniques have been developed for the DPGS to consolidate the integration. In light of the above, this paper reviews the power-conversion and control technologies used for DPGSs. The impacts of the DPGS on the distributed grid are also examined, and more importantly, strategies for enhancing the connection and protection of the DPGS are discussed.

14 March 2023 in Proceedings of the IEEE
Verified
Journal Article
Open access
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Yongheng YangYongheng Yang
Yongheng Yang
KKKatherine A. Kim
Katherine A. Kim
Jose RodriguezJose Rodriguez
Jose Rodriguez
Grid integration of renewable energy (REN) requires efficient and reliable power conversion stages, particularly with an increasing demand for high controllability and flexibility seen from the grid side. Underpinned by advanced control and information technologies, power electronics converters play an essential role in large-scale REN generation. However, the use of power converters has also exposed several challenges in conventional power grids, e.g., reducing the system inertia. In this article, grid integration using power electronics is presented for large-scale REN generation. Technical issues and requirements are discussed with a special focus on grid-connected wind, solar photovoltaic, and energy storage systems. In addition, the core of the energy generation and conversion—control for individual power converters (e.g., general current control) and for the system level (e.g., coordinated operation of large-scale energy systems)—is briefly discussed. Future research perspectives are then presented, which further advance large-scale REN generation technologies by incorporating more power electronics systems.

20 September 2013 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Yongheng YangYongheng Yang
Yongheng Yang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Huai WangHuai Wang
Huai Wang
Transformerless photovoltaic (PV) inverters are going to be more widely adopted in order to achieve high efficiency, as the penetration level of PV systems is continuously booming. However, problems may arise in highly PV-integrated distribution systems. For example, a sudden stoppage of all PV systems due to anti-islanding protection may contribute to grid disturbances. Thus, standards featuring with ancillary services for the next-generation PV systems are under a revision in some countries. The future PV systems have to provide a full range of services as what the conventional power plants do, e.g., low-voltage ride-through (LVRT) under grid faults and grid support service. In order to map future challenges, the LVRT capability of three mainstream single-phase transformerless PV inverters under grid faults is explored in this paper. Control strategies with reactive power injection are also discussed. The selected inverters are the full-bridge (FB) inverter with bipolar modulation, the FB inverter with dc bypass, and the Highly Efficient and Reliable Inverter Concept (HERIC). A 1-kW single-phase grid-connected PV system is analyzed to verify the discussions. The tests confirmed that, although the HERIC inverter is the best candidate in terms of efficiency, it is not very particularly feasible in case of a voltage sag. The other two topologies are capable of providing reactive current during LVRT. A benchmarking of those inverters is also provided in this paper, which offers the possibility to select appropriate devices and to further optimize the transformerless system.

10 May 2016 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WYWenli Yao
Wenli Yao
Yongheng YangYongheng Yang
Yongheng Yang
XZXiaobin Zhang
Xiaobin Zhang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
PLPoh Chiang Loh
Poh Chiang Loh
Resonant poles of LCL filters may challenge the entire system stability especially in digital-controlled pulse width modulation (PWM) inverters. In order to tackle the resonance issues, many active damping solutions have been reported. For instance, a notch filter can be employed to damp the resonance, where the notch frequency should be aligned exactly to the resonant frequency of the LCL filter. However, parameter variations of the LCL filter as well as the time delay appearing in digital control systems will induce resonance drifting, and thus break this alignment, possibly deteriorating the original damping. In this paper, the effectiveness of the notch filter-based active damping is first explored, considering the drifts of the resonant frequency. It is revealed that when the resonant frequency drifts away from its nominal value, the phase lead or lag introduced by the notch filter may make itself fail to damp the resonance. Specifically, the phase lag can make the current control stable despite of the resonant frequency drifting, when the grid current is fed back. In contrast, in the case of an inverter current feedback control, the influence of the phase lead or lag on the active damping is dependent on the actual resonant frequency. Accordingly, in this paper, the notch frequency is designed away from the nominal resonant frequency to tolerate the resonance drifting, being the proposed robust active damping. Simulations and experiments performed on a 2.2-kW three-phase grid-connected PWM inverter verify the effectiveness of the proposed design for robust active damping using digital notch filters.

6 August 2015 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Ariya SangwongwanichAriya Sangwongwanich
Ariya Sangwongwanich
Yongheng YangYongheng Yang
Yongheng Yang
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
An advanced power control strategy by limiting the maximum feed-in power of PV systems has been proposed, which can ensure a fast and smooth transition between maximum power point tracking and constant power generation (CPG). Regardless of the solar irradiance levels, high-performance and stable operation are always achieved by the proposed control strategy. It can regulate the PV output power according to any set point, and force the PV systems to operate at the left side of the maximum power point without stability problems. Experimental results have verified the effectiveness of the proposed CPG control in terms of high accuracy, fast dynamics, and stable transitions.

7 October 2014 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
RPRafael Pena-Alzola
Rafael Pena-Alzola
MLMarco Liserre
Marco Liserre
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
MOMartin Ordonez
Martin Ordonez
Yongheng YangYongheng Yang
Yongheng Yang
Grid-connected converters employ LCL-filters, instead of simple inductors, because they allow lower inductances while reducing cost and size. Active damping, without dissipative elements, is preferred to passive damping for solving the associated stability problems. However, large variations in the grid inductance may compromise system stability, and this problem is more severe for parallel converters. This situation, typical of rural areas with solar and wind resources, calls for robust LCL-filter design. This paper proposes a design procedure with remarkable results under severe grid inductance variation. The procedure considers active damping using lead-lag network and capacitor current feedback. Passive damping is also discussed. The design flow, with little iteration and no complex algorithms, selects the proper ratios between the switching and resonance frequency, the grid and converter inductance, and the filter capacitance and total inductance. An estimation for the grid current total harmonic distortion (THD) is also proposed. Simulation and experiments validate the proposals.