In the chemical and petroleum industry, the axial flow pump is widely used for the circulation pipeline system, and most of the transportation mediums are the shear-thinning non-Newtonian fluids. However, previous investigations on axial flow pumps are focused on water, which leads to a considerable deviation between the actual application and the research finding. In this work, shear-thinning non-Newtonian fluid (CMC solution) and viscous Newtonian fluid (the viscosity equals the apparent viscosity of CMC solution as the flow index is 1) are selected as the working medium. Based on the research output, lower apparent viscosity occurs in the near-wall and rotor–stator interaction region due to the larger velocity gradient. The shear-thinning property results in an increased tip leakage flow rate, and a sharp decline in friction loss. Compared to the viscous Newtonian fluid, the head and efficiency of the pump improves substantially for the shear-thinning fluid. The discrepancy is observed to increase with a higher flow rate. The comprehensive analysis of flow field and energy performance reveals that friction loss is still the main part of the total loss in the shear-thinning fluid.
The multiphase rotodynamic pump is widely used in petroleum and gas exploitation, and blade tip clearance may cause flow instability and performance deterioration. In the present work, the influence of tip clearance on the transportation characteristic in a multiphase rotodynamic pump is investigated based on the non-uniform bubble model, in which the bubbles’ coalescence and break-up are considered. The influence mechanism of tip clearance on the energy performance is revealed. The results show that the leakage flow rate increases linearly with the increase in tip clearance, but variation in pump energy performance shows the opposite trend. In addition, a larger tip clearance results in a sharply decreased pressure increment in the impeller, while in the guide vane, the increment is raised slightly. For the 0 mm tip clearance condition, a positive vortex (relative to the impeller rotation direction) is observed in the impeller passage. However, the opposite leakage vortex is also found in the region near the tip clearance when the tip clearance is considered, and the vortex strength increases for a larger tip clearance.
6 July 2023 in Chemical Engineering Communications
Hydropower as a flexible regulation resource is a rare choice to suppress the ever-increasing penetration of wind power in electrical power systems. The complementary characteristics and performance improvement of a hydro–wind hybrid power system based on a mathematical model of the hybrid power system is studied in this paper. This established model takes into account the stochastic variation in wind speeds in the wind power subsystem and the hydraulic–mechanical–electrical coupling characteristics of the hydropower subsystem. The complementary analysis is conducted based on the evaluation variables outputted by the established model, such as the wind power, hydro-regulation power, hydraulic power, and frequency. To make full use of the regulation capability of the hydropower system, the optimization of parameter settings is also carried out to improve complementary performances of the hybrid power system. The results from the complementary analysis show the detailed characteristics of hydro–wind coordinated operation under different types of real wind speeds. Here, 95% of installed hydro-capacity is used to complement the power shortage of the intermittent wind energy under the low wind speed. Alternatively, only around 66% of the installed hydro-capacity can be utilized to cope with the fluctuation in wind power under the medium and high wind speeds before the optimization of parameter settings. The recommended values and change rules of the control, hydraulic, and electrical parameters for the hydropower system are subsequently revealed from the analysis of parameter settings to contribute to a stable and safe hybrid power system. The results show that the optimized parameter can increase the maximal regulating capacity of the hydropower system by nearly 9 MW, approximately a sixth of the total installed hydropower capacity. The method and results obtained in this paper provide theoretical and technical guidance for the safe and economical operation of power stations.