Incorporating Internet of Things (IoT) technology into the operation of buildings is expected to generate immense synergy, thereby saving energy and improving occupant comfort by overcoming the limitations of the existing system. Preventing operations in the absence of occupants can save energy, and the occupants’ preferred operating temperature should be used as the control set-point rather than the nominal temperature. In this study, IoT technology and image sensors are used to rapidly detect indoor environment changes, and a method is proposed to utilize air quality and thermal comfort as the control set-points. A real-time ventilation control algorithm is proposed based on the CO2 concentration calculated according to the number of occupants. To check the thermal comfort level, the real-time operating temperature estimated from the surface temperature data of the infrared array sensor is reflected in the comfort zone defined by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The deficiencies in indoor environment conditions caused by the temporal and spatial lag of sensors in the old system are minimized using IoT technology, which also facilitates wireless communications. The image sensors can be used for multiple purposes based on various interpretations of the image information obtained.
It has been identified that improving building energy efficiency is an effective method to reduce greenhouse gas (GHG) emissions. Although standards have been established to satisfy a building’s minimum energy demand while ensuring the comfort of its residents, they are difficult to implement in mixed-humid regions. This study proposes a hybrid ventilation strategy that can comprehensively reduce cooling, heating, and ventilation energy in mixed-humid climate regions to significantly decrease the primary energy demand and reduce the impact of buildings on the environment. This study evaluated the changes in energy saving potential and thermal comfort according to the extension of the natural ventilation period and passive strategies, such as decentralized ventilation. Changes in indoor air temperature, operative temperature, and PMV for each strategy were analyzed. As a result, extending the natural ventilation and the decentralized ventilation strategies can save 32% and 34% of the building’s energy, respectively. Considering that electricity is the main energy source for cooling in Korea, the extension of the natural ventilation period was judged to be the best approach from the perspective of primary energy demand. The results can be used to predict changes in building energy demand and thermal comfort and select an appropriate ventilation strategy based on occupant information obtained using Internet of Things.
Since P.O. Fanger proposed PMV, it has been the most widely used index to estimate thermal comfort. However, in some cases, it is challenging to measure all six parameters within indoor spaces, which are essential for PMV estimation; a couple of parameters, such as Clo or Met, tend to show a large deviation in accuracy. For these reasons, several studies have suggested methods to estimate PMV but their accuracies were significantly compromised. In this vein, this study proposed a way to reduce the dimensions of parameters for PMV prediction utilizing the machine learning method, in order to provide fast PMV calculations without compromising its prediction accuracy. Throughout this study, the most influential features for PMV were pinpointed using PCA, Best Subset, and the Gini Importance, with each model compared to the others. The results showed that PCA and ANN achieved the highest accuracy of 89.70%, and the combination of Best Subset and Random Forest showed the fastest prediction performance among all.