LUCA SOLIMEI

Dr. LUCA SOLIMEI

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Silvia RaveraSilvia Ravera
Silvia Ravera
ECEsteban Colombo
Esteban Colombo
CPClaudio Pasquale
Claudio Pasquale
SBStefano Benedicenti
Stefano Benedicenti
LSLUCA SOLIMEI
LUCA SOLIMEI
Andrea AmaroliAndrea Amaroli
Andrea Amaroli
Background: Injury of the trigeminal nerve in oral and maxillofacial surgery can occur. Schwann cell mitochondria are regulators in the development, maintenance and regeneration of peripheral nerve axons. Evidence shows that after the nerve injury, mitochondrial bioenergetic dysfunction occurs and is associated with pain, neuropathy and nerve regeneration deficit. A challenge for research is to individuate new therapies able to normalise mitochondrial and energetic metabolism to aid nerve recovery after damage. Photobiomodulation therapy can be an interesting candidate, because it is a technique involving cell manipulation through the photonic energy of a non-ionising light source (visible and NIR light), which produces a nonthermal therapeutic effect on the stressed tissue. Methods: The review was based on the following questions: (1) Can photo-biomodulation by red and NIR light affect mitochondrial bioenergetics? (2) Can photobiomodulation support damage to the trigeminal nerve branches? (preclinical and clinical studies), and, if yes, (3) What is the best photobiomodulatory therapy for the recovery of the trigeminal nerve branches? The papers were searched using the PubMed, Scopus and Cochrane databases. This review followed the ARRIVE-2.0, PRISMA and Cochrane RoB-2 guidelines. Results and conclusions: The reliability of photobiomodulatory event strongly bases on biological and physical-chemical evidence. Its principal player is the mitochondrion, whether its cytochromes are directly involved as a photoacceptor or indirectly through a vibrational and energetic variation of bound water: water as the photoacceptor. The 808-nm and 100 J/cm2 (0.07 W; 2.5 W/cm2; pulsed 50 Hz; 27 J per point; 80 s) on rats and 800-nm and 0.2 W/cm2 (0.2 W; 12 J/cm2; 12 J per point; 60 s, CW) on humans resulted as trustworthy therapies, which could be supported by extensive studies.

18 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Nicola De AngelisNicola De Angelis
Nicola De Angelis
LSLUCA SOLIMEI
LUCA SOLIMEI
CPClaudio Pasquale
Claudio Pasquale
Lorenzo AlvitoLorenzo Alvito
Lorenzo Alvito
ALAlberto Lagazzo
Alberto Lagazzo
FBFabrizio Barberis
Fabrizio Barberis
Bone augmentation procedures represent a real clinical challenge. One option is the use of titanium meshes. Additive manufacturing techniques can provide custom-made devices in titanium alloy. The purpose of this study was to investigate the material used, which can influence the outcomes of the bone augmentation procedure. Specific test samples were obtained from two different manufacturers with two different shapes: surfaces without perforations and with calibrated perforations. Three-point bending tests were run as well as internal friction tests to verify the Young’s modulus. Test samples were placed in two different buffered solutions and analyzed with optical microscopy. A further SEM analysis was done to observe any microstructural modification. Three-point flexural tests were conducted on 12 specimens. Initial bending was observed at lower applied stresses for the perforated samples (503 MPa) compared to non-perforated ones (900 MPa); the ultimate flexural strength was registered at 513 MPa and 1145 MPa for perforated and non-perforated samples, respectively. Both microscopic analyses (optical and SEM) showed no significant alterations. Conclusions: A normal masticatory load cannot modify the device. Chemical action in the case of exposure does not create macroscopic and microscopic alterations of the surface.

18 September 2024 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
AAAli Shahi Ardakani
Ali Shahi Ardakani
SBStefano Benedicenti
Stefano Benedicenti
LSLUCA SOLIMEI
LUCA SOLIMEI
SSSima Shahabi
Sima Shahabi
SAShima Afrasiabi
Shima Afrasiabi
Objectives: The aim of this study is to investigate the antimicrobial efficacy of antimicrobial photodynamic therapy (PDT) using natural photosensitizers (curcumin, riboflavin, and phycocyanin) and light-emitting diode (LED) irradiation against multispecies biofilms in an acrylic denture base model. Materials and Methods: Forty-five acrylic specimens were fabricated using heat-curing acrylic resin. The specimens were then infected with a mixed culture of bacterial and fungal species (including Streptococcus mutans, Streptococcus sanguinis, Candida albicans, and Candida glabrata) for 4 days. The acrylic discs were divided into nine groups, with each group containing five discs: control, 0.2% chlorhexidine, 5.25% sodium hypochlorite, curcumin, riboflavin, phycocyanin alone or along with LED. After treatment, the number of colony-forming units (CFUs) per milliliter was counted. In addition, the extent of biofilm degradation was assessed using the crystal violet staining method and scanning electron microscopy. Results: All experimental groups exhibited a significant reduction in colony numbers for both bacterial and fungal species compared to the control (p < 0.001). The PDT groups exhibited a statistically significant reduction in colony counts for both bacteria and fungi compared to the photosensitizer-only groups. Conclusions: The results of this in vitro study show that PDT with natural photosensitizers and LED devices can effectively reduce the viability and eradicate the biofilm of microorganisms responsible for causing denture infections.

21 October 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Hadi AssadianHadi Assadian
Hadi Assadian
SFSadaf Fathollahi
Sadaf Fathollahi
MPMaryam Pourhajibagher
Maryam Pourhajibagher
LSLUCA SOLIMEI
LUCA SOLIMEI
SBStefano Benedicenti
Stefano Benedicenti
NCNasim Chiniforush
Nasim Chiniforush
Aim: To compare shock wave-enhanced emission photoacoustic streaming (SWEEPS) with sonic- and ultrasonically activated irrigation systems in removing Enterococcus faecalis biofilm from the root canal system. Methodology: Fifty human single-canalled mandibular premolars were included in the study. After access cavity preparation, the root canals were prepared to a standardized size and taper. Then, the entire root surface was covered with two layers of resin, and the root apices were sealed before sterilization. All root canals were inoculated with E. faecalis biofilm, and the samples were incubated aerobically for 2 weeks at 37 °C. Biofilm formation was confirmed by scanning electron microscopy. All samples were randomly divided into five groups (n = 10 each) based on their irrigation activation method as A (no treatment or negative control), B (no irrigation or positive control), C (sonically activated irrigation (SAI)), D (ultrasonically activated irrigation (UAI)), and E (needle irrigation activated by an Er: YAG laser device using a SWEEPS quartz tip (SWEEPS)). Then, dentine chips were retrieved, vortexed, and diluted for colony-forming unit counts. Data were analysed using analysis of variance and post-hoc Tukey tests (α = 5%). Results: All methods could significantly reduce E. faecalis biofilm compared with control so that the UAI, SWEEPS, and SAI groups indicated a 23.54%, 14.89%, and 7.81% biofilm reduction, respectively. UAI demonstrated a significantly more effective reduction of E. faecalis biofilm than SAI (p = 0.004). Conclusions: All irrigation activation methods significantly reduced E. faecalis biofilm, with ultrasonic use being the most effective.

11 October 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
DFDavide Foschi
Davide Foschi
Andrea AbateAndrea Abate
Andrea Abate
Cinzia MasperoCinzia Maspero
Cinzia Maspero
LSLUCA SOLIMEI
LUCA SOLIMEI
CLClaudio Lanteri
Claudio Lanteri
Lanteri ValentinaLanteri Valentina
Lanteri Valentina
The materials available today allow for extensive oral rehabilitations in a non-invasive way, and often an orthodontic preparation is useful and, thanks to the use of clear aligners, is predictable and comfortable. A preliminary study of the wax-up, mock-up, and set-up allow the clinician to plan every aspect of the treatment in detail. Furthermore, the procedure offers the patient an intuitive and understandable view of the expected final result. The new proposed method, called “speed up therapy”, allows for the integration of the orthodontic set-up with the mock-up technique, simulating the occlusal and aesthetic components of the planned restoration, in all details. The clinical case presented, demonstrates step by step the predictability and clinical reliability of the proposed procedure. The final clinical result coincides exactly with the initial mock-up and demonstrates that the proposed method is predictable and reliable. The correct execution of the technique is rigorously customized, and its success is operator dependent, both for the clinical aspects and for the dental laboratory. Thus, the visualization of the objectives of the treatment constitutes a decisive support for the clinician and provides the patient with the possibility of benefiting from an immediate improvement by making it easier for them to accept a treatment plan. The visualization also includes an orthodontic phase that potentially lengthens the treatment but makes the realization more conservative and predictable.

26 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Nicola De AngelisNicola De Angelis
Nicola De Angelis
Antonio SignoreAntonio Signore
Antonio Signore
AAArwa Alsayed
Arwa Alsayed
Wong Hai HockWong Hai Hock
Wong Hai Hock
LSLUCA SOLIMEI
LUCA SOLIMEI
Andrea AmaroliAndrea Amaroli
Andrea Amaroli
(1) Background. Dental implant placement in the anterior region requires extreme precision due to relatively high aesthetic demand. This narrative review aimed to analyse some of the available clinical studies of the socket-shield technique and determine its viability for dental implant survival/success and complication rates. (2) Methods. An electronic search for publications was performed using the Cochrane, PubMed-MEDLINE, Web of Science, and Google Scholar databases. All electronic searches included human clinical and animal studies and were performed by three independent examiners. (3) Results. A total of 1383 records were identified with the initial search strategies, but only 25 full texts + five abstracts clinical studies were kept after the recruitment criteria screening. The technical details, advantages, and limitations of the techniques were illustrated. (4) Conclusion. Within the limitations of the present review, it would be merely justified that immediate dental implant placement in conjunction with the socket-shield technique can be a promising strategy for dental implant therapy.