Transverse post-tensioning arrangement in prefabricated prestressed concrete (PC) box-girder bridge can effectively improve the transverse connection’s performance to avoid stress concentration. The number of transverse post-tensioning tendons and the transverse post-tensioning force are crucial factors determining the live load’s lateral distribution. Four prefabricated PC box-girder model tests were carried out to calculate the lateral distribution of the live load. Based on experimental results, the recommended values of the reduction factors of contact interfaces considering the effective longitudinal transfer length of transverse post-tensioning were given, and a simplified method of lateral distribution factor was proposed. The proposed simplified method results were compared with the PCI code, experiments, finite element method, articulated plate method, and rigid-plate method. The results showed that the lateral distribution factor calculated by the simplified method agreed with the results of experiments and the finite element method. The average relative differences were less than 8%. In comparison, the relative differences were more than 15% for the PCI code, articulated plate method, and rigid plate method. Thus, the proposed method could meet the engineering application and be adopted to calculate the lateral distribution factor of bridges with transverse post-tensioning.
The dynamic response stability analysis of the anchored surrounding rock during blasting construction is crucial to ensure the safety of construction. Taking the Wuwan Tunnel in Luoyang as the engineering background, combined with methods such as physical simulation experiments, numerical simulation experiments, and on-site experiments, the asymmetric effects of layered rock mass on the surrounding rock and support structure during blasting excavation were studied. The asymmetric effects of tunnel blasting excavation on the surrounding rock and support system under the condition of a bedding angle of 30° were analyzed and summarized. The results indicate that when the blasting stress wave passes through the bedding plane, the stress wave will undergo significant attenuation. The strain generated by the anchor rod passing through the bedding plane exhibits asymmetry due to the reflection and weakening of the blasting stress wave after passing through the bedding plane.
To investigate the coupled effects of cable corrosion on the ultimate strength and fatigue performance of cable-stayed bridges, sophisticated numerical simulations incorporating established corrosion mechanisms were conducted. Corrosion-induced degradation was modeled through cross-sectional area reduction and material property deterioration, with specific emphasis on wire elongation capacity attenuation. Three finite element models representing steel cable-stayed bridges with distinct spans (300 m, 600 m, and 900 m) were subjected to progressive collapse analysis and fatigue assessment. The results indicate that: (1) Structural failure consistently manifested through plastic hinge formation and fracture at the mid-span girder across all models, accompanied by partial plastification at the tower base; (2) Increased span length elevated cable stress at failure, thereby amplifying the influence of cross-sectional area reduction on ultimate strength; (3) Reduction of wire elongation rate from 4% to 3% or 2% resulted in marginal ultimate strength reductions, whereas attenuation to 1% induced precipitous capacity decline; (4) Under concurrent minimum cable area and elongation rate conditions, the ultimate load-bearing capacity of all bridge configurations experienced an approximate 50% reduction; (5) Corrosion significantly compromised fatigue performance at all cable positions, with localized pitting corrosion exacerbating stress concentration effects and accelerating cross-sectional degradation, consequently diminishing fatigue life.
4 August 2026 in Journal of the Brazilian Society of Mechanical Sciences and Engineering