Sridhar Yaddanapudi

Dr. Sridhar Yaddanapudi


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2015 in Medical Physics
Verified
Journal Article
Closed access
BSBaozhou Sun
Baozhou Sun
SGS. Murty Goddu
S. Murty Goddu
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
CNCamille Noel
Camille Noel
HLHua Li
Hua Li
SMSasa Mutic
Sasa Mutic

1 April 2013 in Practical Radiation Oncology
Verified
Journal Article
Closed access
DRDharanipathy Rangaraj
Dharanipathy Rangaraj
MZMingyao Zhu
Mingyao Zhu
DYDeshan Yang
Deshan Yang
GPGeethpriya Palaniswaamy
Geethpriya Palaniswaamy
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
SMSasa Mutic
Sasa Mutic

6 September 2012 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
BSBaozhou Sun
Baozhou Sun
DRDharanipathy Rangaraj
Dharanipathy Rangaraj
SBSunita Boddu
Sunita Boddu
MGMurty Goddu
Murty Goddu
DYDeshan Yang
Deshan Yang
SMSasa Mutic
Sasa Mutic
Experimental methods are commonly used for patient‐specific IMRT delivery verification. There are a variety of IMRT QA techniques which have been proposed and clinically used with a common understanding that not one single method can detect all possible errors. The aim of this work was to compare the efficiency and effectiveness of independent dose calculation followed by machine log file analysis to conventional measurement‐based methods in detecting errors in IMRT delivery. Sixteen IMRT treatment plans (5 head‐and‐neck, 3 rectum, 3 breast, and 5 prostate plans) created with a commercial treatment planning system (TPS) were recalculated on a QA phantom. All treatment plans underwent ion chamber (IC) and 2D diode array measurements. The same set of plans was also recomputed with another commercial treatment planning system and the two sets of calculations were compared. The deviations between dosimetric measurements and independent dose calculation were evaluated. The comparisons included evaluations of DVHs and point doses calculated by the two TPS systems. Machine log files were captured during pretreatment composite point dose measurements and analyzed to verify data transfer and performance of the delivery machine. Average deviation between IC measurements and point dose calculations with the two TPSs for head‐and‐neck plans were and , respectively. For 2D diode array measurements, the mean gamma value with 3% dose difference and 3 mm distance‐to‐agreement was within 1.5% for 13 of 16 plans. The mean 3D dose differences calculated from two TPSs were within 3% for head‐and‐neck cases and within 2% for other plans. The machine log file analysis showed that the gantry angle, jaw position, collimator angle, and MUs were consistent as planned, and maximal MLC position error was less than 0.5 mm. The independent dose calculation followed by the machine log analysis takes an average , while the experimental approach (using IC and 2D diode array measurements) takes an average about 2 hours in our clinic. Independent dose calculation followed by machine log file analysis can be a reliable tool to verify IMRT treatments. Additionally, independent dose calculations have the potential to identify several problems (heterogeneity calculations, data corruptions, system failures) with the primary TPS, which generally are not identifiable with a measurement‐based approach. Additionally, machine log file analysis can identify many problems (gantry, collimator, jaw setting) which also may not be detected with a measurement‐based approach. Machine log file analysis could also detect performance problems for individual MLC leaves which could be masked in the analysis of a measured fluence. PACS numbers: 87.53.Bn, 87.55.Qr, 87.55.km, 87.57.Uq

18 July 2012 in Medical Physics
Verified
Journal Article
Closed access
DYDeshan Yang
Deshan Yang
YWYu Wu
Yu Wu
RBRyan S. Brame
Ryan S. Brame
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
DRDharanipathy Rangaraj
Dharanipathy Rangaraj
SMSasa Mutic
Sasa Mutic

1 October 2013 in Practical Radiation Oncology
Verified
Journal Article
Closed access
BSBaozhou Sun
Baozhou Sun
DRDharanipathy Rangaraj
Dharanipathy Rangaraj
GPGeethpriya Palaniswaamy
Geethpriya Palaniswaamy
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
OWOmar Wooten
Omar Wooten
LSLakshmi Santanam
Lakshmi Santanam

1 November 2014 in Practical Radiation Oncology
Verified
Journal Article
Closed access
LOLindsey A. Olsen
Lindsey A. Olsen
CRClifford G. Robinson
Clifford G. Robinson
GHGuangrong R. He
Guangrong R. He
HWH. Omar Wooten
H. Omar Wooten
SYSridhar Yaddanapudi
Sridhar Yaddanapudi
KMKevin L. Moore
Kevin L. Moore