Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM) is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement results. This paper presents a normal spring constant calibration method with the combined use of an electromagnetic balance and a homemade AFM head. When the cantilever presses the balance, its deflection is detected through an optical lever integrated in the AFM head. Meanwhile, the corresponding bending force is recorded by the balance. Then the spring constant can be simply calculated using Hooke’s law. During the calibration, a feedback loop is applied to control the deflection of the cantilever. Errors that may affect the stability of the cantilever could be compensated rapidly. Five types of commercial cantilevers with different shapes, stiffness, and operating modes were chosen to evaluate the performance of our system. Based on the uncertainty analysis, the expanded relative standard uncertainties of the normal spring constant of most measured cantilevers are believed to be better than 2%.
A hybrid atomic force microscopic (AFM) measurement system combined with white light scanning interferometry for micro/nanometer dimensional measurement is developed. The system is based on a high precision large-range positioning platform with nanometer accuracy on which a white light scanning interferometric module and an AFM head are built. A compact AFM head is developed using a self-sensing tuning fork probe. The head need no external optical sensors to detect the deflection of the cantilever, which saves room on the head, and it can be directly fixed under an optical microscopic interferometric system. To enhance the system’s dynamic response, the frequency modulation (FM) mode is adopted for the AFM head. The measuring data can be traceable through three laser interferometers in the system. The lateral scanning range can reach 25 mm × 25 mm by using a large-range positioning platform. A hybrid method combining AFM and white light scanning interferometry is proposed to improve the AFM measurement efficiency. In this method, the sample is measured firstly by white light scanning interferometry to get an overall coarse morphology, and then, further measured with higher resolution by AFM. Several measuring experiments on standard samples demonstrate the system’s good measurement performance and feasibility of the hybrid measurement method.
Here we investigate the growth of the pentacene thin film on the quartz (0001) surface. The evolution of the optical properties of the pentacene thin film has been monitored in situ by optical spectroscopy and the thin-film morphology was investigated ex situ by atomic force spectroscopy. We find that (001)-oriented thin-film phase pentacene crystallites grow on a one-monolayer-thick interfacial layer. The optical and structural properties of the first monolayer determined in situ and ex situ, respectively, differ substantially from those of the multilayers. Most importantly, the distinct optical properties of the first monolayer are preserved when the interface becomes buried during the subsequent pentacene thin-film formation.
With its unique structure, the Akiyama probe is a type of tuning fork atomic force microscope probe. The long, soft cantilever makes it possible to measure soft samples in tapping mode. In this article, some characteristics of the probe at its second eigenmode are revealed by use of finite element analysis (FEA) and experiments in a standard atmosphere. Although the signal-to-noise ratio in this environment is not good enough, the 2 nm resolution and 0.09 Hz/nm sensitivity prove that the Akiyama probe can be used at its second eigenmode under FM non-contact mode or low amplitude FM tapping mode, which means that it is easy to change the measuring method from normal tapping to small amplitude tapping or non-contact mode with the same probe and equipment.
A method for measuring the nonlinearity of laser interferometer using optical frequency tuning technique is presented in this paper. The basic principle of this method is to make the fractional part of an interference fringe change by tuning the laser frequency and determining the nonlinearity of interferometer by comparing the fractional fringe change measured by the interferometer to that calculated from the laser frequency change. An experimental interferometric system with a wavelength tunable laser source is set up and the nonlinearity of the interferometer is measured. Since it does not require the precise displacement mechanism to produce the optical path difference change, this method is more convenient to use and may achieve a higher accuracy than the conventional measurement methods. The nonlinearity of the arbitrary interferometric phase can be measured by changing the laser frequency with this method. Experiments results have shown that the repeatability of nonlinearity measurement is less than 0.2 nm. This method can be applied to interferometry-based high precision dimensional measurements, such as coordinate measurement and displacement sensor calibration.
The adsorption of perfluoropentacene (PFP) on the Cu(110) surface has been investigated using reflectance difference spectroscopy (RDS), low-energy electron diffraction, and low-temperature scanning tunneling microscopy. The PFP molecules within the first monolayer align their long molecular axis exclusively oriented along the [001] azimuthal direction of the Cu substrate. In comparison with the adsorption behavior of pentacene on the same surface, a strong effect of the fluorination regarding the molecular orientation and the intermolecular and molecule-substrate interactions was identified. Furthermore, a two-dimensional gas-solid phase transition accompanied by a reversible azimuthal rotation of the PFP molecules was observed at the beginning of the second monolayer growth. The change of the optical anisotropy associated with this reorientation was used to explore the two-dimensional (2D) condensation as a function of coverage and temperature by RDS, and the 2D heat of condensation in the PFP bilayer on Cu(110) was determined to be 105 meV.