Yong Bao

Dr. Yong Bao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Yong BaoYong Bao
Yong Bao
RZRui Zhang
Rui Zhang
EGEnemali Godwin
Enemali Godwin
ZCZhang Cao
Zhang Cao
BZBin Zhou
Bin Zhou
CLChang Liu
Chang Liu
Tunable diode laser absorption spectroscopy (TDLAS) tomography has been widely used for in situ combustion diagnostics, yielding images of both species concentration and temperature. The temperature image is generally obtained from the reconstructed absorbance distributions for two spectral transitions, i.e., two-line thermometry. However, the inherently ill-posed nature of tomographic data inversion leads to noise in each of the reconstructed absorbance distributions. These noise effects propagate into the absorbance ratio and generate artifacts in the retrieved temperature image. To address this problem, we have developed a novel algorithm, which we call Relative Entropy Tomographic RecOnstruction (RETRO), for TDLAS tomography. A relative entropy regularization is introduced for high-fidelity temperature image retrieval from jointly reconstructed two-line absorbance distributions. We have carried out numerical simulations and proof-of-concept experiments to validate the proposed algorithm. Compared with the well-established simultaneous algebraic reconstruction technique (SART), the RETRO algorithm significantly improves the quality of the tomographic temperature images, exhibiting excellent robustness against TDLAS tomographic measurement noise. RETRO offers great potential for industrial field applications of TDLAS tomography, where it is common for measurements to be performed in very harsh environments.

17 October 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Yong BaoYong Bao
Yong Bao
JJJiabin Jia
Jiabin Jia
Acoustic tomography can deliver accurate quantitative reconstruction of the covered temperature distribution with low equipment cost. For the application of real-time temperature field monitoring, both the temporal resolution and reconstruction speed are of great significance. In this paper, we developed a novel online time-resolved reconstruction (OTRR) methods, which can improve temporal resolution to capture dynamic changes and accelerate the tomographic reconstruction process for online real-time monitoring. Firstly, by exploiting the redundancy of the temporal information, a temporal regularisation is designed based on adaptive auto aggressive (AR) model to reduce the required amount of TOF data per frame. A sliding overlapping window is applied to further improve the reconstruction accuracy. Secondly, recursive reconstruction process performs a sliding iteration over each data segment. For the reconstruction of each frame, the online computation is non-iterative. Numerical simulation and lab-scale experiment are performed to validate the proposed OTRR method. The reconstruction images are compared with the online time-resolved reconstruction methods based on Kalman filter. Results show that our method can improve the temporal resolution the computational time and produce acceptable results.

18 May 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RZRui Zhang
Rui Zhang
JSJingjing Si
Jingjing Si
EGEnemali Godwin
Enemali Godwin
Yong BaoYong Bao
Yong Bao
CLChang Liu
Chang Liu
This paper develops a size-adaptive hybrid meshing scheme for Chemical Species Tomography (CST) that is driven by the customized spatial resolution of the sensing region. Traditionally, the entire sensing region in CST is uniformly discretized with the empirically determined density of the meshes. Such a discretization results in a) waste of computational efforts on the less spatially resolved location; and b) much severer rank deficiency. To solve the above-mentioned issues, we introduce, for the first time, a size-adaptive hybrid meshing scheme for CST. Driven by the spatial resolution, dense meshes are deployed in the region of interest (RoI) to detail the target flow field while sparse ones are deployed out of the RoI to fully consider the physically existing laser absorption. The proposed scheme is numerically validated using a CST sensor with 128 laser beams. The visual and quantitative metric comparisons show that the proposed hybrid-size meshing scheme outperforms the traditionally uniform-size meshing scheme, giving 35% lower image error and 38% less significant dislocation at a typical 35 dB signal-to-noise ratio in the RoI. The proposed hybrid-size meshing scheme significantly facilitates the reconstruction of the industrial combustion processes where the combustion zone is bypassed by cooling flows. In these scenarios, the proposed scheme can adapt a finer resolution to detail the combustion zone, while maintaining the integrity of the physical model by less resolved reconstruction of the bypass flows.

8 March 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Yong BaoYong Bao
Yong Bao
Chao TanChao Tan
Chao Tan
DFDong Feng
Dong Feng
Ultrasonic techniques have been widely used to determine the volume fractions of liquid components in oil–water two-phase flow. The two major ultrasonic interactions amenable to volume fraction estimation are the sound speed and attenuation. Instead of using these two linear ultrasound parameters, this study explores the use of ultrasound nonlinear parameter to measure the volume fraction of oil–water two-phase flow. Based on the theoretical modeling of ultrasound nonlinear propagation and nonlinearity measurement principle using finite amplitude insertion substitution (FAIS), we established a relationship between volume fraction and the amplitude of the second harmonic components in the received ultrasound waveform. With the use of high-intensity ultrasonic excitation, two-end calibration, and second harmonic amplitude extraction, the volume fraction of water can be calculated. The performance of the proposed method is validated by the numerical simulations and experimental studies in a lab-scale flow loop. Good qualitative agreement between the model and results shows that the nonlinear ultrasonic measurement technique has good quantitative accuracy and high measurement sensitivity, which make it well suited for industrial applications.

2 June 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
Yong BaoYong Bao
Yong Bao
Chao TanChao Tan
Chao Tan
JJJiabin Jia
Jiabin Jia
With the advantages of high accuracy, high spatial resolution, and long measurement range, LiDAR is considered as the most suitable measurement technique to deliver quantitative imaging of wind fields. However, for complex wind fields, such as monitoring wind turbine wakes where both the temporal resolution and reconstruction speed are of great significance, the conventional LiDAR system lacks the temporal resolution to capture the fast changes of wind turbine wake fields. In this paper, a novel dynamic wind retrieval method is developed to improve temporal resolution using the unsynchronised dual-LiDAR scanning scheme. By exploiting the temporal redundancy information of the LiDAR Line-of-Sight (LoS) data in successive frames, a reduced number of LiDAR scanning points is required for the 2D horizontal wind field retrieval with the help of unsynchronised dual-LiDAR wind scanning scheme, low-rank data up-sampling and a divergence-free regularised wind retrieval algorithm. Numerical simulation is performed to validate the proposed method. Results show that the temporal resolution of LiDAR wind retrieval can be improved by a factor of 2 to 8 and provide acceptable results with good spatial resolution.

18 December 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
STSheng Tian
Sheng Tian
Chao TanChao Tan
Chao Tan
ZZZhixing Zhang
Zhixing Zhang
Yong BaoYong Bao
Yong Bao
DFDong Feng
Dong Feng
Oil-gas-water three-phase medium is frequently encountered in various industrial processes. A comprehensive understanding of the discrete phase is of great importance for the industrial process safety assurance and economic benefits of production. Concerns about the discrete phase in the three-phase medium not only refer to the spatial resolution but also acoustically distinguish the gas bubble and oil droplet. We present a novel ultrasonic measurement technique for the three-phase medium using the ultrasonic phased array (UPA) sensor and complex sound pressure measurement to accomplish this goal. The proposed method can provide accurate size and location measurements to resolve the bubble and droplet spatially, and accurate acoustic impedance measurements to distinguish the bubble and droplet in oil-gas-water three-phase medium. Briefly, we develop a forward scattering complex sound pressure peak (FSCSPP) method to quantitatively characterize the size and distribution of the bubble and droplet, a sound transmission degree (STD) method to calculate these discrete phases’ acoustic impedance values, and a sound transmission threshold (STT) parameter to distinguish the bubble and droplet. The simulation and experimental results show that the above method is highly accurate and sensitive in spatially resolving and acoustically distinguishing the bubble and droplet in the oil-gas-water three-phase medium.