Travel time based hydraulic tomography is a technique for reconstructing the spatial distribution of aquifer hydraulic properties (e.g., hydraulic diffusivity). Simultaneous Iterative Reconstruction Technique (SIRT) is a widely used algorithm for travel time related inversions. Due to the drawbacks of SIRT implementation in practice, a modified SIRT with Cimmino iteration (SIRT-Cimmino) is proposed in this study. The incremental correction is adjusted, and an iteration-dependent relaxation parameter is introduced. These two modifications enable an appropriate speed of convergence, and the stability of the inversion process. Furthermore, a new result selection rule is suggested to determine the optimal iteration step and its corresponding result. SIRT-Cimmino and SIRT are implemented and verified by using two numerical aquifer models with different predefined (“true”) diffusivity distributions, where high diffusivity zones are embedded in a homogenous low diffusivity field. Visual comparison of the reconstructions shows that the reconstruction based on SIRT-Cimmino demonstrates the aquifer’s hydraulic features better than the conventional SIRT algorithm. Root mean square errors and correlation coefficients are also used to quantitatively evaluate the performance of the inversion. The reconstructions based on SIRT-Cimmino are found to preserve the connectivity of the high diffusivity zones and to provide a higher structural similarity to the “true” distribution.
Monitoring the migration of sequestered CO2 in deep heterogeneous reservoirs is inherently difficult. Geophysical methods have been successfully used, but flow conditions are only indirectly linked to the measured properties. Besides geophysical methods, pressure tomography (PT) is proposed as an alternative method to depict the structure of deep saline formations for CO2 sequestration and to continuously delineate CO2 plumes. In contrast to more established geophysical measurements, pressure transients are directly related to flow properties, which allows for the estimation of permeability. We investigate the influence of aquifer heterogeneity on PT performance, and we compare the PT results to crosshole seismic tomography (ST). Multilevel fluid injections and high-frequency P-wave pulses are induced in a simulated deep borehole, and the recorded signals at another well are processed by a traveltime inversion scheme. The reservoir structure is inferred by clustering the inverted hydraulic diffusivity prior to CO2 injection, and the plume distribution is determined by clustering the tomograms of the inverted mixed-phase diffusivity difference and P-wave velocity difference. The clustered structures are then used for zonal calibration to acquire the saturation within the plumes. Modeling results indicate that PT provides clearer structural information on the CO2-free aquifer due to its direct linkage to permeability. However, the plume depicted by PT can be ambiguous, whereas ST is less sensitive to the prevailing heterogeneity of permeability at postinjection and can thus image the plume more clearly. PT and ST can be complementary to each other through the joint clustering to improve plume shape identification and estimation of spatial CO2 saturation.
Ground source heat pumps (GSHPs) are highly efficient for heating and cooling buildings. Among the different types of ground source heat pumps, horizontal ground heat exchangers (HGHEs) gaining popularity due to their cost-effectiveness, ease of installation and high regeneration capacity. However, studies on the interaction and influence of the local environment with the HGHE and the thermal performance influenced by the arrangement and performance of the HGHE are insufficient. This study uses a three-dimensional numerical model to simulate three types of HGHEs, including linear-loop, spiral-coil, and slinky-coil arrangements. Instead of just one unit, three units are connected in series or parallel. The model considers the energy balance and the heat transfer and exchange processes between the heat exchanger and the soil. Simulation of cooling and heating for 1 year revealed that the slinky-coil arrangement is the most affected by heat fluxes at the ground surface, because of its maximum length, which leads to its lowest coefficient of performance (COP) value. The thermal performance of linear-loop and spiral-coil arrangements is similar, but considering the material cost, the linear-coil arrangement has the lowest installation cost and operating cost for 30 years.