Interleukin-6 (IL-6) can cause pro- and anti-inflammatory effects via different signaling pathways. This prospective study investigated the perioperative kinetics of IL-6, soluble IL-6 receptor (sIL-6R), and soluble glycoprotein 130 (sgp130) in elective patients undergoing cardiopulmonary bypass (CPB). IL-6, sIL-6R, and sgp130 were measured simultaneously and consecutively at 19 timepoints until the 10th postoperative day (POD). The proportion of pro- and anti-inflammatory pathways were determined by calculating sIL-6R/IL-6 and sIL-6R/sgp130 ratios. We analyzed 93 patients. IL-6 increased during surgery with reaching a plateau two hours after CPB and peaking on POD 1 (188.5 pg mL−1 (IQR, 126.6; 309.2)). sIL-6R decreased at the beginning of the surgical procedure, reaching a nadir level on POD 2 (26,311 pg mL−1 (IQR, 22,222; 33,606)). sgp130 dropped immediately after CPB initiation (0.13 ng mL−1 (IQR, 0.12; 0.15)), followed by a continuous recovery until POD10. The sIL-6R/IL-6 ratio decreased substantially at the beginning of the procedure, reaching a nadir on POD 1 (149.7 (IQR, 82.4; 237.4)), while the sIL-6R/sgp130 ratio increased simultaneously until 6 h post CPB (0.219 (IQR 0.18; 0.27)). In conclusion, IL-6 exhibited high inter-individual variability reflecting an inhomogeneous inflammatory response. Pro-inflammatory effects and overwhelming inflammation were rare and predominantly anti-inflammatory effects were found.
25 November 2022 in Journal of Cardiothoracic and Vascular Anesthesia
Objectives The identification of potential hemodynamic indicators to increase the predictive power of stroke-volume variation (SVV) for mean arterial pressure (MAP) and stroke volume (SV) fluid responsiveness. Design A prospective intervention study. Setting At a single-center university hospital. Participants Nineteen patients during major vascular surgery with 125 fluid interventions. Interventions When SVV ≥13% occurred for >30 seconds, 250 mL of Ringer's lactate were given within 2 minutes. Measurements and Main Results Hemodynamic variables, such as pulse-pressure variation (PPV) and dynamic arterial elastance (Edyn), were measured by pulse power-wave analysis. The outcomes were MAP and SV responsiveness, defined as an increase of at least 10% of MAP and SV within 5 minutes of the fluid intervention. Of the fluid interventions, 48% were MAP-responsive, and 66% were SV-responsive. The addition of PPV and Edyn cut-off values to the SVV cut-off decreased sensitivity from 1-to-0.66 to-0.82, and concomitantly increased specificity from 0-to- 0.65-to-0.93 for the prediction of MAP and SV responsiveness in the authors’ study setting. The areas under the receiver operating characteristic curves of PPV and Edyn for the prediction of MAP responsiveness were 0.79 and 0.75, respectively. The areas under the receiver operating characteristic curves for PPV and Edyn to predict SV responsiveness were 0.85 and 0.77, respectively. Conclusions The PPV and Edyn showed good accuracy for the prediction of MAP and SV responsiveness in patients with elevated SVV during vascular surgery. Either PPV or Edyn may be used in conjunction with SVV to better predict MAP and SV fluid responsiveness in patients undergoing vascular surgery.
Background: Respiratory heat exchange is an important physiological process occurring in the upper and lower respiratory tract and is usually completed when inspired gases reach the alveoli. Animal and human studies demonstrated that heat exchange can be modulated by altering pulmonary ventilation and perfusion. The purpose of this study was to examine the effect of acute ventilation-perfusion (V/Q) mismatch on respiratory heat exchange. In clinical practice, monitoring respiratory heat exchange might offer the possibility of real-time tracking of acute V/Q-mismatch. Methods: In 11 anesthetized, mechanically ventilated pigs, V/Q-mismatch was established by means of four interventions: single lung ventilation, high cardiac output, occlusion of the left pulmonary artery and repeated whole-lung lavage. V/Q-distributions were determined by the multiple inert gas elimination technique (MIGET). Respiratory heat exchange was measured as respiratory enthalpy using the novel, pre-commercial VQm™ monitor (development stage, Rostrum Medical Innovations, Vancouver, CA). According to MIGET, shunt perfusion of low V/Q compartments increased during single lung ventilation, high cardiac output and whole-lung lavage, whereas dead space and ventilation of high V/Q compartments increased during occlusion of the left pulmonary artery and whole-lung lavage. Results: Bohr dead space increased after pulmonary artery occlusion and whole-lung lavage, venous admixture increased during single lung ventilation and whole-lung lavage, PaO2/FiO2 was decreased during all interventions. MIGET confirmed acute V/Q-mismatch. Respiratory enthalpy did not change significantly despite significant acute V/Q-mismatch. Conclusion: Clinically relevant V/Q-mismatch does not impair respiratory heat exchange in the absence of additional thermal stressors and may not have clinical utility in the detection of acute changes.
22 September 2026 in International Journal of Antimicrobial Agents