In the paper we present the results obtained for the effect of rotation (ROT) in the angular distribution of prompt rays from the fission of induced by monochromatic polarized “warm” neutrons ( = 60 meV). The polarization vector direction is determined at the target position in order to correctly determine the sign of the measured effect. The asymmetry parameter was found to be equal to . Moreover, the rotation angle of the fission axis was determined to be equal to taking into account the fit results of the angular distribution of the prompt fission rays. The obtained value and sign of the ROT effect are consistent with the results of the ROT effect obtained for cold neutrons. We describe the experiment, methodology of sign determination, and implications of the results.
22 December 2023 in Nuclear Engineering and Technology
Cross sections for the reaction were systematically measured at incident neutron energies in the range of 3.3 to 5.3 MeV. The experiment was carried out on the Van de Graaff accelerator EG-5 at the Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Russia. Fast neutrons were produced in the reaction . Alpha particles from the () reactions were detected using a gridded ionization chamber (GIC) in which various samples (NaCl and , on a tantalum backing) were placed back to back. The relative and absolute neutron fluxes were measured by two samples of () inside the GIC. Data obtained in this measurement were compared with other experimental data of the existing library and theoretical calculations by the talys code. Presented data for the reaction should help to clarify discrepancies in the various published nuclear data.
14 July 2015 in Physics of Particles and Nuclei Letters
The silicon based pixel detector Timepix is a multi-parameter detector which gives simultaneously information about position, energy and arrival time of a particle hitting the detector. Applying the ΔE-E method with these detectors makes it possible to determine types of detected particles, separating them by charge. Using a thin silicon detector with thickness of 12 μm combined with a Timepix (300 μm), a ΔE-E telescope has been constructed. The telescope provides information about position, energy, time and type of registered particles. The emission probabilities and the energy distributions of ternary particles (He, Li, Be) from 252Cf spontaneous fission source were determined using this telescope. Besides the ternary particles, a few events were collected, which were attributed to the “pseudo” quaternary fission.
10 October 2024 in IEEE Transactions on Nuclear Science
Traditional approach of spectroscopy signals acquisition and analysis comprises digitization performed ideally by a high bit resolution and short sampling period flash ADC, followed by a subsequent digital processing requiring a high computational performance. However, some particular applications cannot implement that traditional approach while demanding comparable high spectroscopic performance due to hardware limitations mainly given by operational conditions, availability of qualified electronic components, power consumption limit, etc. The Dynamic Time Over Threshold (DTOT) conversion method-based processing of spectroscopy signals represents an undemanding alternative in contrary to that traditional approach. The detailed study of DTOT method-based processing was performed with the aim to maximize achievable performance via extension of the dynamic range allowing to process a wide span of input spectroscopy signals. The contribution also presents practical implementation of front-end electronics integrating an enhanced DTOT converter structure dedicated to a gamma detector (based on sensors of SiPM type) while test measurements with common reference radiation sources were performed to provide comparative results.
Background Silicon Photomultipliers (SiPMs) are crucial devices in various photon-counting applications. They are mainly produced with two pixel structures, with deeply burned and surface pixel designs offering distinct advantages. This study investigates the impact of these structural differences on key parameters of two representative SiPMs: the MAPD-3NM-II (Zecotek Photonics) with a deeply burned structure and the MPPC S12572-010P (Hamamatsu Photonics) with a surface pixel structure. Method The performance of MAPD-3NM-II and MPPC S12572-010P was evaluated using multiple techniques. Breakdown voltage was determined using three different methods: I-V measurements, the Miller method, and the single photoelectron method. Temperature dependence was analyzed by measuring the breakdown voltage across a temperature range of 23°C to 43°C. Finally capacitance measurements were performed using a sinusoidal signal with constant amplitude and frequency, where determined using reference capacitance. Results The results from all three methods were consistent, yielding a breakdown voltage of 52.22±0.07 V for the MAPD-3NM-II and 68.08±0.10 V for the MPPC S12572-010P, within experimental uncertainties. The optimal operating voltage was determined as Ubr+4 V for the MAPD-3NM-II and Ubr+4.5 V for the MPPC S12572-010P. The temperature dependence of breakdown voltage was also investigated, revealing that the MAPD-3NM-II exhibited a lower temperature coefficient (51.32±0.44 mV/°C) compared to the MPPC S12572-010P (57.01±0.56 mV/°C). This indicates that the MAPD-3NM-II is more thermally stable. Capacitance measurements demonstrated that the MAPD-3NM-II exhibited significantly lower capacitance (155±12 pF) than the MPPC S12572-010P (294±26 pF). Conclusions This study provides a comparative analysis of two SiPMs with different pixel structures. The findings highlight the potential advantages of deeply burned pixel structures in terms of reduced capacitance and improved thermal stability. The lower capacitance of the MAPD-3NM-II suggests its suitability for large-area detector implementations. The results show that MAPD type photodiodes can be used in radiation detectors used in medicine and radiation monitoring systems.