Ahmed Alghamdi

Dr. Ahmed Alghamdi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AAAhmed Alghamdi
Ahmed Alghamdi
TAThaar Mohammad Aljuwaya
Thaar Mohammad Aljuwaya
AAAbdullah S. Alomari
Abdullah S. Alomari
Muthanna Al-DahhanMuthanna Al-Dahhan
Muthanna Al-Dahhan
In the past two decades, the radioactive particle tracking (RPT) measurement technique has been proven to visualize flow fields of most multiphase flow systems of industrial interest. The accuracy of RPT, and hence the data obtained, depend largely on the calibration process, which stands here as a basis for two subsequent processes: tracking and reconstruction. However, limitations in the RPT calibration process can be found in different experimental constrains and in assumptions made in the classical Monte Carlo approach used to simulate number of counts received by the detectors. Therefore, in this work, we applied a GEANT4-based Monte Carlo code to simulate the RPT calibration process for an investigated multiphase flow system (i.e., gas–liquid bubble column). The GEANT4 code was performed to simulate the number of counts received by 28 scintillation detectors for 931 known tracer positions while capturing all the types of photon interaction and overcoming solids’ angle limitations in classical approaches. The results of the simulation were validated against experimental data obtained using an automated RPT calibration device. The results showed a good agreement between the simulated and experimental counts, where the maximum absolute average relative deviation detected was about 5%. The GEANT4 model typically predicted the number of counts received by all the detectors; however, it over-estimated the counts when the number of primary events applied in the model was not the optimal.

28 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AAAlhussain A. Abuhoza
Alhussain A. Abuhoza
HKHamoud Kassim
Hamoud Kassim
AAAhmed Alghamdi
Ahmed Alghamdi
FAFaisal M. Alrumayan
Faisal M. Alrumayan
MAMehenna Arib
Mehenna Arib
MAMeshari ALQahtani
Meshari ALQahtani
A CS-30 cyclotron has been in operation at King Faisal Specialist Hospital and Research Center (KFSHRC) since 1982. The CS-30 cyclotron has been used to produce medical radioisotopes for positron emission tomography (PET) and single-photon emission computed tomography (SPECT). Some of the nuclear reactions of radionuclide production are associated with the intense release of a wide range of fast neutrons. In this work, we investigated the radionuclides produced from neutron interactions with the cyclotron facility walls. Activation isotopes were determined by performing gamma ray spectrometry utilizing a high-purity germanium (HPGe) detector. The major radionuclides found were 152Eu, 154Eu, 134Cs, 65Zn and 60Co. Activation isotope accumulation had increased the dose rate inside the facility. The surface dose rates were measured at all of the surrounding walls. The maximum surface dose rate was found to be 1.2 µSv/h, which is much lower than the permissible occupational exposure of 15 µSv/h based daily 5 work hours.

1 April 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
AAAhmed Alghamdi
Ahmed Alghamdi
ELEric Lukosi
Eric Lukosi

19 February 2023 in Processes
Verified
Journal Article
Open access
PDF file
AAAlaa Hadi Alnahdi
Alaa Hadi Alnahdi
AAAhmed Alghamdi
Ahmed Alghamdi
AAAbdullah I. Almarshad
Abdullah I. Almarshad
The goal of this study was to evaluate the impact of simulating different fuel shapes for the material testing reactor (MTR). Two OpenMC codes were built, and the first OpenMC model was simulated using a curved shape fuel element to mimic the real dimensions and shape of the MTR. The code core parameters were validated with the collected parameters from the experimental work and two well-known Monte Carlo simulation codes (MCNP and SCALE). The validation process included the axial flux profile and criticality. After the OpenMC curve fuel model was validated, the MTR fuel was simulated as flat fuel elements with the exact amount of fuel as in the curve fuel model. By comparing the two OpenMC models’ calculations, it was observed that the radial flux distribution has only a slight difference due to fuel mass similarity. In conclusion, simulating the MTR fuel as flat elements provided a good agreement calculation compared to the real shape, but it was also observed that this might carry some discrepancies for in-depth simulation studies.

20 June 2018 in Journal of Spectroscopy
Verified
Journal Article
Open access
PDF file
AAAhmed Alghamdi
Ahmed Alghamdi
LHLawrence Heilbronn
Lawrence Heilbronn
LCLuis A. Castellanos
Luis A. Castellanos
ELEric Lukosi
Eric Lukosi
Experimental and computational results of a ΔE/ΔE diamond detection system are presented. The ΔE/ΔE detection system was evaluated using energetic proton and iron beams striking thick polyethylene targets at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The measured data for diamond sensor A show good agreement with the Geant4 simulation. In addition, simulations have demonstrated the ability to identify hydrogen isotopes using a diamond detection system.