Three-dimensional (3D) speckle-tracking echocardiography (3DSTE) is an advanced imaging technique designed for left ventricular (LV) myocardial deformation analysis based on 3D data sets. 3DSTE has the potential to overcome some of the intrinsic limitations of two-dimensional STE (2DSTE) in the assessment of complex LV myocardial mechanics, offering additional deformation parameters (such as area strain) and a comprehensive quantitation of LV geometry and function from a single 3D acquisition. Albeit being a relatively young technique still undergoing technological developments, several experimental studies and clinical investigations have already demonstrated the reliability and feasibility of 3DSTE, as well as several advantages of 3DSTE over 2DSTE. This technique has provided new insights into LV mechanics in several clinical fields, such as the objective assessment of global and regional LV function in ischemic and non-ischemic heart diseases, the evaluation of LV mechanical dyssynchrony, as well as the detection of subclinical cardiac dysfunction in cardiovascular conditions at risk of progression to overt heart failure. However, 3DSTE generally requires patient’s breathhold and regular rhythm for enabling an ECG-gated multi-beat 3D acquisition. In addition, the measurements, normal limits and cut-off values pertaining to 3D strain parameters are currently vendor-specific and highly dependent on the 3D ultrasound equipment used. Technological advances with improvement in spatial and temporal resolution and a standardized methodology for obtaining vendor-independent 3D strain measurements are expected in the future for a widespread application of 3DSTE in both clinical and research arenas. The purpose of this review is to summarize currently available data on 3DSTE methodology (feasibility, accuracy and reproducibility), strengths and weaknesses with respect to 2DSTE, as well as the main clinical applications and future research priorities of this emerging technology.
T(The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
The Stress Echo 2030 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
+87
With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: the ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF); 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021–2025) ≥10,000 patients followed for ≥5 years (up to 2030) from ≥20 quality-controlled laboratories from ≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient.
O(on behalf of Stress Echo 2020 and 2030 study group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
on behalf of Stress Echo 2020 and 2030 study group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
+29
Background: Lung ultrasound detects pulmonary congestion as B-lines at rest, and more frequently, during exercise stress echocardiography (ESE). Methods: We performed ESE plus lung ultrasound (4-site simplified scan) in 4392 subjects referred for semi-supine bike ESE in 24 certified centers in 9 countries. B-line score ranged from 0 (normal) to 40 (severely abnormal). Five different populations were evaluated: control subjects (n=103); chronic coronary syndromes (n=3701); heart failure with reduced ejection fraction (n=395); heart failure with preserved ejection fraction (n=70); ischemic mitral regurgitation ≥ moderate at rest (n=123). In a subset of 2478 patients, follow-up information was available. Results: During ESE, B-lines increased in all study groups except controls. Age, hypertension, abnormal ejection fraction, peak wall motion score index, and abnormal heart rate reserve were associated with B-lines in multivariable regression analysis. Stress B lines (hazard ratio, 2.179 [95% CI, 1.015–4.680]; P =0.046) and ejection fraction <50% (hazard ratio, 2.942 [95% CI, 1.268–6.822]; P =0.012) were independent predictors of all-cause death (n=29 after a median follow-up of 29 months). Conclusions: B-lines identify the pulmonary congestion phenotype at rest, and more frequently, during ESE in ischemic and heart failure patients. Stress B-lines may help to refine risk stratification in these patients. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT 03049995.
O(on behalf of the Stress Echo 2020 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
on behalf of the Stress Echo 2020 Study Group of the Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI)
+10
Background: In patients with Ischemia and non-obstructive coronary artery stenosis (INOCA) wall motion is rarely abnormal during stress echocardiography (SE). Our aim was to determine if patients with INOCA and reduced coronary flow velocity reserve (CVFR) have altered cardiac mechanics using two-dimensional speckle-tracking echocardiography (2DSTE) during SE. Methods: In a prospective, multicenter, international study, we recruited 135 patients with INOCA. Overall, we performed high dose (0.84 mg/kg) dipyridamole SE with combined assessment of CVFR and 2DSTE. The population was divided in patients with normal CVFR (>2, group 1, n = 95) and abnormal CVFR (≤2, group 2, n = 35). Clinical and 2DSTE parameters were compared between groups. Results: Feasibility was high for CFVR (98%) and 2DSTE (97%). A total of 130 patients (mean age 63 ± 12 years, 67 women) had complete flow and strain data. The two groups showed similar 2DSTE values at rest. At peak SE, Group 1 patients showed lower global longitudinal strain (p < 0.007), higher mechanical dispersion (p < 0.0005), lower endocardial (p < 0.001), and epicardial (p < 0.0002) layer specific strain. Conclusions: In patients with INOCA, vasodilator SE with simultaneous assessment of CFVR and strain is highly feasible. Coronary microvascular dysfunction is accompanied by an impairment of global and layer-specific deformation indices during stress.