This paper presents a traveling-wave-based fault-location algorithm for hybrid multiterminal transmission systems that consist of one onshore overhead lines and multiple offshore submarine cables. Such hybrid transmission systems are common for interconnection of offshore wind farms to the main grid. The input to the algorithm is synchronized transient voltage measurements from all of the receiving ends. These measurements are obtained by optical voltage transducers equipped with global positioning system receivers for time synchronization. The discrete wavelet transformation is utilized to decompose the mode-1 voltages at the receiving ends. The first wave arrival times are then obtained by observing the squares of the wavelet transformation coefficient (WTC 2 ). The transient simulations and the postfault analysis are carried out using EMTP-RV and MATLAB Wavelet Toolbox, respectively. The accuracy, limitations, and capabilities of the proposed algorithm are presented and discussed for different fault conditions.
This paper proposes a new technique for detection of traveling-wave arrival times in power systems. Precise estimation of wave arrival times improves most of the traveling-wave-based fault location methods. The proposed technique is based on the short-time matrix pencil method that decomposes the measurement samples in a sliding window into time-indexed complex frequencies. Traveling-wave arrival times are estimated based on the fact that the extracted damping factors (i.e., the real part of the complex frequencies) are zero when the arriving wave is located in the middle of the sliding window. The proposed technique is compared to the existing transient-detection techniques such as discrete wavelet transform with commonly used mother wavelets and Hilbert transform (HT), using MATLAB Wavelet Toolbox and MATLAB HT. The sensitivity analysis based on the simulation results demonstrates that the proposed technique is less affected by the measurement noise, sampling frequency, and fault parameters.
1 March 2018 in International Journal of Electrical Power & Energy Systems
A great number of existing power transmission lines have aged throughout the world. A considerable proportion of them are located in the environments that exacerbate their corrosion and erosion process. In-time detection of defects necessitates the use of nondestructive testing (NDT) techniques. Scanning the lines with robots and helicopters are the methods in use. In this paper, we propose a new NDT technique that uses the elements of power-line carriers, generally for information communication purposes, to detect the possibly corroded and eroded segments of each phase along a transmission line. The proposed NDT technique is based on the backward-wave propagation produced by a change in the characteristic impedance of a power transmission line, resulting from corrosion and erosion. To demonstrate the viability of the proposed approach, “EMTPWorks” is used to perform simulations. It is shown that the proposed technique can locate the surface defects and estimate the severity of them in transmission line conductors.
23 October 2018 in IEEE Transactions on Power Delivery
This paper proposes a novel recursive method for detecting the first arrival time (AT) of traveling waves (TWs) in power grids to enhance the fault-location methods relying on TWs. This method depends on the adaptive discrete Kalman filter (ADKF). It estimates the parameters of a high time-resolution voltage or current measurement and generates residuals (innovation sequence). Both measurement noises and TWs can result in an abrupt change in the residuals. The proposed method pinpoints the probable abrupt change and distinguishes whether it is resulted by noises or arriving waves. As the proposed method is recursive, it is proper for implementation in on-site digital fault locators for real-time applications. For evaluation of the proposed method, EMTP-RV and the real-time digital simulator (RTDS) are utilized to perform the transient simulations. The results are then analyzed in MATLAB. The proposed method and the state-of-the-art AT-detection methods in the prior literature are compared, and the sensitivity analysis demonstrates that the measurement noises and fault parameters have less influence on the proposed method efficiency in comparison to the existing AT-detection methods.