Bernard ten Haken

Bernard ten Haken


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in British Journal of Radiology
Verified
Journal Article
Closed access
JPJoost J Pouw
Joost J Pouw
MGMaarten R Grootendorst
Maarten R Grootendorst
RBRoland Bezooijen
Roland Bezooijen
CKCaroline A H Klazen
Caroline A H Klazen
WBWieger I De Bruin
Wieger I De Bruin
BHBernard ten Haken
Bernard ten Haken
Objective:Sentinel lymph node biopsy (SLNB) with a superparamagnetic iron oxide (SPIO) tracer was shown to be non-inferior to the standard combined technique in the SentiMAG Multicentre Trial. The MRI subprotocol of this trial aimed to develop a magnetic alternative for pre-operative lymphoscintigraphy (LS). We evaluated the feasibility of using MRI following the administration of magnetic tracer for pre-operative localization of sentinel lymph nodes (SLNs) and its potential for non-invasive identification of lymph node (LN) metastases.Methods:Patients with breast cancer scheduled to undergo SLNB were recruited for pre-operative LS, single photon emission CT (SPECT)-CT and SPIO MRI. T1 weighted turbo spin echo and T2 weighted gradient echo sequences were used before and after interstitial injection of magnetic tracer into the breast. SLNs on MRI were defined as LNs with signal drop and direct lymphatic drainage from the injection site. LNs showing inhomogeneous SPIO uptake were classified as metastatic. D...

18 February 2016 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
RBR. Blankena
R. Blankena
RKR. Kleinloog
R. Kleinloog
BVB. H. Verweij
B. H. Verweij
POPim van Ooij
Pim van Ooij
BHBernard ten Haken
Bernard ten Haken
JZJ. J. M. Zwanenburg
J. J. M. Zwanenburg
BACKGROUND AND PURPOSE: Both hemodynamics and aneurysm wall thickness are important parameters in aneurysm pathophysiology. Our aim was to develop a method for semi-quantitative wall thickness assessment on in vivo 7T MR images of intracranial aneurysms for studying the relation between apparent aneurysm wall thickness and wall shear stress. MATERIALS AND METHODS: Wall thickness was analyzed in 11 unruptured aneurysms in 9 patients who underwent 7T MR imaging with a TSE-based vessel wall sequence (0.8-mm isotropic resolution). A custom analysis program determined the in vivo aneurysm wall intensities, which were normalized to the signal of nearby brain tissue and were used as measures of apparent wall thickness. Spatial wall thickness variation was determined as the interquartile range in apparent wall thickness (the middle 50% of the apparent wall thickness range). Wall shear stress was determined by using phase-contrast MR imaging (0.5-mm isotropic resolution). We performed visual and statistical comparisons (Pearson correlation) to study the relation between wall thickness and wall shear stress. RESULTS: 3D colored apparent wall thickness maps of the aneurysms showed spatial apparent wall thickness variation, which ranged from 0.07 to 0.53, with a mean variation of 0.22 (a variation of 1.0 roughly means a wall thickness variation of 1 voxel [0.8 mm]). In all aneurysms, apparent wall thickness was inversely related to wall shear stress (mean correlation coefficient, −0.35; P < .05). CONCLUSIONS: A method was developed to measure the wall thickness semi-quantitatively, by using 7T MR imaging. An inverse correlation between wall shear stress and apparent wall thickness was determined. In future studies, this noninvasive method can be used to assess spatial wall thickness variation in relation to pathophysiologic processes such as aneurysm growth and rupture.

20 October 2020 in Cancers
Verified
Journal Article
Open access
PDF file
RMRutger Mahieu
Rutger Mahieu
JMJosanne Sophia de Maar
Josanne Sophia de Maar
ENEliane Nieuwenhuis
Eliane Nieuwenhuis
RDRoel Deckers
Roel Deckers
CMChrit Moonen
Chrit Moonen
Remco De BreeRemco De Bree
Remco De Bree
Sentinel lymph node biopsy (SLNB) is a diagnostic staging procedure that aims to identify the first draining lymph node(s) from the primary tumor, the sentinel lymph nodes (SLN), as their histopathological status reflects the histopathological status of the rest of the nodal basin. The routine SLNB procedure consists of peritumoral injections with a technetium-99m [99mTc]-labelled radiotracer followed by lymphoscintigraphy and SPECT-CT imaging. Based on these imaging results, the identified SLNs are marked for surgical extirpation and are subjected to histopathological assessment. The routine SLNB procedure has proven to reliably stage the clinically negative neck in early-stage oral squamous cell carcinoma (OSCC). However, an infamous limitation arises in situations where SLNs are located in close vicinity of the tracer injection site. In these cases, the hotspot of the injection site can hide adjacent SLNs and hamper the discrimination between tracer injection site and SLNs (shine-through phenomenon). Therefore, technical developments are needed to bring the diagnostic accuracy of SLNB for early-stage OSCC to a higher level. This review evaluates novel SLNB imaging techniques for early-stage OSCC: MR lymphography, CT lymphography, PET lymphoscintigraphy and contrast-enhanced lymphosonography. Furthermore, their reported diagnostic accuracy is described and their relative merits, disadvantages and potential applications are outlined.

1 February 2015 in International Journal of Nanomedicine
Verified
Journal Article
Open access
JPJoost J Pouw
Joost J Pouw
MAMuneer Ahmed
Muneer Ahmed
BABauke Anninga
Bauke Anninga
KSKimberley Schuurman
Kimberley Schuurman
SPSarah Pinder
Sarah Pinder
BHBernard ten Haken
Bernard ten Haken
Introduction: Breast cancer staging with sentinel lymph node biopsy relies on the use of radioisotopes, which limits the availability of the procedure worldwide. The use of a magnetic nanoparticle tracer and a handheld magnetometer provides a radiation-free alternative, which was recently evaluated in two clinical trials. The hydrodynamic particle size of the used magnetic tracer differs substantially from the radioisotope tracer and could therefore benefit from optimization. The aim of this study was to assess the performance of three different-sized magnetic nanoparticle tracers for sentinel lymph node biopsy within an in vivo porcine model. Materials and methods: Sentinel lymph node biopsy was performed within a validated porcine model using three magnetic nanoparticle tracers, approved for use in humans (ferumoxytol, with hydrodynamic diameter dH =32 nm; Sienna+®, dH =59 nm; and ferumoxide, dH =111 nm), and a handheld magnetometer. Magnetometer counts (transcutaneous and ex vivo), iron quantification (vibrating sample magnetometry), and histopathological assessments were performed on all ex vivo nodes. Results: Transcutaneous “hotspots” were present in 12/12 cases within 30 minutes of injection for the 59 nm tracer, compared to 7/12 for the 32 nm tracer and 8/12 for the 111 nm tracer, at the same time point. Ex vivo magnetometer counts were significantly greater for the 59 nm tracer than for the other tracers. Significantly more nodes per basin were excised for the 32 nm tracer compared to other tracers, indicating poor retention of the 32 nm tracer. Using the 59 nm tracer resulted in a significantly higher iron accumulation compared to the 32 nm tracer. Conclusion: The 59 nm tracer demonstrated rapid lymphatic uptake, retention in the first nodes reached, and accumulation in high concentration, making it the most suitable tracer for intraoperative sentinel lymph node localization.

1 February 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
MLMelissa Horstman - van de Loosdrecht
Melissa Horstman - van de Loosdrecht
SDS. Draack
S. Draack
SWSebastiaan Waanders
Sebastiaan Waanders
JSJ. G. L. Schlief
J. G. L. Schlief
HKH. J. G. Krooshoop
H. J. G. Krooshoop
BHBernard ten Haken
Bernard ten Haken
Superparamagnetic iron oxide nanoparticles (SPIONs) are used as a tracer material in sentinel node biopsies. The latter is a procedure to analyze if cancer cells have spread to lymph nodes, helping to personalize patient care. To predict SPION behavior in vivo, it is important to analyze their magnetic properties in biological environments. The superparamagnetic quantifier (SPaQ) is a new device to measure the dynamic magnetization curve of SPIONs. The magnetization curve was measured for two types of SPIONs: Resovist and SHP-25. We used three techniques: Vibrating Sample Magnetometry (VSM), Magnetic Particle Spectroscopy (MPS), and our new SPaQ. Furthermore, AC susceptibility (ACS) measurements were performed as part of the evaluation of the three techniques. SPaQ and VSM results were found to be similar. Measurement results were nearly identical in both directions, indicating minor hysteresis. However, in MPS measurements, a clear hysteresis loop was observed. Furthermore, the ACS measurements showed a pronounced Brownian maximum, indicating an optimal response for an AC frequency below 10 kHz for both particle systems. Both the SPaQ and MPS were found to be superior to VSM since measurements are faster, can be performed at room temperature, and are particularly sensitive to particle dynamics. The main difference between the SPaQ and MPS lies in the excitation sequence. The SPaQ combines an alternating magnetic field that has a low amplitude with a gradual DC offset, whereas MPS uses only an alternating field that has a large amplitude. In conclusion, both the SPaQ and MPS are highly suited to improve understanding SPION behavior, which will lead to the radical improvement of sentinel node biopsy accuracy.

15 December 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MRMax Rietberg
Max Rietberg
SWSebastiaan Waanders
Sebastiaan Waanders
MLMelissa Horstman - van de Loosdrecht
Melissa Horstman - van de Loosdrecht
RWRogier R. Wildeboer
Rogier R. Wildeboer
BHBernard ten Haken
Bernard ten Haken
Lejla AlicLejla Alic
Lejla Alic
The efficient development and utilisation of magnetic nanoparticles (MNPs) for applications in enhanced biosensing relies on the use of magnetisation dynamics, which are primarily governed by the time-dependent motion of the magnetisation due to externally applied magnetic fields. An accurate description of the physics involved is complex and not yet fully understood, especially in the frequency range where Néel and Brownian relaxation processes compete. However, even though it is well known that non-zero, non-static local fields significantly influence these magnetisation dynamics, the modelling of magnetic dynamics for MNPs often uses zero-field dynamics or a static Langevin approach. In this paper, we developed an approximation to model and evaluate its performance for MNPs exposed to a magnetic field with varying amplitude and frequency. This model was initially developed to predict superparamagnetic nanoparticle behaviour in differential magnetometry applications but it can also be applied to similar techniques such as magnetic particle imaging and frequency mixing. Our model was based upon the Fokker–Planck equations for the two relaxation mechanisms. The equations were solved through numerical approximation and they were then combined, while taking into account the particle size distribution and the respective anisotropy distribution. Our model was evaluated for Synomag®-D70, Synomag®-D50 and SHP-15, which resulted in an overall good agreement between measurement and simulation.