For assistive devices such as active orthoses, exoskeletons or other close-to-body robotic-systems, the immediate prediction of biological limb movements based on biosignals in the respective control system can be used to enable intuitive operation also by untrained users e.g. in healthcare, rehabilitation or industrial scenarios. Surface electromyography (sEMG) signals from the muscles that drive the limbs can be measured before the actual movement occurs and, hence, can be used as source for predicting limb movements. The aim of this work was to create a model that can be adapted to a new user or movement scenario with little measurement and computing effort. Therefore, a biomechanical model is presented that predicts limb movements of the human forearm based on easy to measure sEMG signals of the main muscles involved in forearm actuation (lateral and long head of triceps and short and long head of biceps). The model has 42 internal parameters of which 37 were attributed to 8 individually measured physiological measures (location of acromion at the shoulder, medial/lateral epicondyles as well as olecranon at the elbow, and styloid processes of radius/ulna at the wrist; maximum muscle forces of biceps and triceps). The remaining 5 parameters are adapted to specific movement conditions in an optimization process. The model was tested in an experimental study with 31 subjects in which the prediction quality of the model was assessed. The quality of the movement prediction was evaluated by using the normalized mean absolute error (nMAE) for two arm postures (lower, upper), two load conditions (2 kg, 4 kg) and two movement velocities (slow, fast). For the resulting 8 experimental combinations the nMAE varied between nMAE = 0.16 and nMAE = 0.21 (lower numbers better). An additional quality score (QS) was introduced that allows direct comparison between different movements. This score ranged from QS = 0.25 to QS = 0.40 (higher numbers better) for the experimental combinations. The above formulated aim was achieved with good prediction quality by using only 8 individual measurements (easy to collect body dimensions) and the subsequent optimization of only 5 parameters. At the same time, just easily accessible sEMG measurement locations are used to enable simple integration, e.g. in exoskeletons. This biomechanical model does not compete with models that measure all sEMG signals of the muscle heads involved in order to achieve the highest possible prediction quality.
Emulating the highly resource-efficient processing of visual motion information in the brain of flying insects, a bio-inspired controller for collision avoidance and navigation was implemented on a novel, integrated System-on-Chip-based hardware module. The hardware module is used to control visually-guided navigation behavior of the stick insect-like hexapod robot HECTOR. By leveraging highly parallelized bio-inspired algorithms to extract nearness information from visual motion in dynamically reconfigurable logic, HECTOR is able to navigate to predefined goal positions without colliding with obstacles. The system drastically outperforms CPU- and graphics card-based implementations in terms of speed and resource efficiency, making it suitable to be also placed on fast moving robots, such as flying drones.
Limb movement prediction based on surface electromyography (sEMG) for the control of wearable robots, such as active orthoses and exoskeletons, is a promising approach since it provides an intuitive control interface for the user. Further, sEMG signals contain early information about the onset and course of limb movements for feedback control. Recent studies have proposed machine learning-based modeling approaches for limb movement prediction using sEMG signals, which do not necessarily require domain knowledge of the underlying physiological system and its parameters. However, there is limited information on which features of the measured sEMG signals provide the best prediction accuracy of machine learning models trained with these data. In this work, the accuracy of elbow joint movement prediction based on sEMG data using a simple feedforward neural network after training with different single- and multi-feature sets and data segmentation parameters was compared. It was shown that certain combinations of time-domain and frequency-domain features, as well as segmentation parameters of sEMG data, improve the prediction accuracy of the neural network as compared to the use of a standard feature set from the literature.
Parallax, as a visual effect, is used for depth perception of objects. But is there also the effect of parallax in the context of electric field imagery? In this work, the example of weakly electric fish is used to investigate how the self-generated electric field that these fish utilize for orientation and communication alike, may be used as a template to define electric parallax. The skin of the electric fish possesses a vast amount of electroreceptors that detect the self-emitted dipole-like electric field. In this work, the weakly electric fish is abstracted as an electric dipole with a sensor line in between the two emitters. With an analytical description of the object distortion for a uniform electric field, the distortion in a dipole-like field is simplified and simulated. On the basis of this simulation, the parallax effect could be demonstrated in electric field images i.e. by closer inspection of voltage profiles on the sensor line. Therefore, electric parallax can be defined as the relative movement of a signal feature of the voltage profile (here, the maximum or peak of the voltage profile) that travels along the sensor line peak trace (PT). The PT width correlates with the object’s vertical distance to the sensor line, as close objects create a large PT and distant objects a small PT, comparable with the effect of visual motion parallax.