Jessica M. Colon-Franco

Dr. Jessica M. Colon-Franco


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2021 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
JWJared Warren
Jared Warren
HAHiba K. Anis
Hiba K. Anis
KBKathleen Bowers
Kathleen Bowers
TPTejbir Pannu
Tejbir Pannu
JVJesus Villa
Jesus Villa
CHCarlos A. Higuera
Carlos A. Higuera
Background: Despite several synovial fluid biomarkers for the diagnosis of periprosthetic joint infection (PJI) having been investigated, point-of-care (POC) tests using these biomarkers are not widely available. Synovial calprotectin has recently been reported to effectively exclude the diagnosis of PJI. Thus, the objective of this study was to test the value of a calprotectin POC test for PJI diagnosis in patients undergoing total knee arthroplasty (TKA) using the 2013 Musculoskeletal Infection Society (MSIS) PJI diagnosis criteria as the gold standard. Methods: Synovial fluid samples were prospectively collected from 123 patients who underwent revision TKA at 2 institutions within the same health-care system from October 2018 to January 2020. The study was conducted under institutional review board approval. Data collection comprised demographic, clinical, and laboratory data in compliance with the MSIS criteria. Synovial fluid samples were analyzed by calprotectin POC tests in accordance with the manufacturer’s instructions. Revisions were categorized as septic or aseptic using MSIS criteria by 2 independent reviewers blinded to the calprotectin results. Calprotectin test performance characteristics with sensitivities, specificities, positive predictive values, negative predictive values, and areas under the receiver operating characteristic curve (AUC) were calculated for 2 different PJI diagnosis scenarios: (1) a threshold of ≥50 mg/L, and (2) a threshold of ≥14 mg/L. Results: According to the MSIS criteria, 53 revision TKAs were septic and 70 revision TKAs were aseptic. In the ≥50-mg/mL threshold scenario, the calprotectin POC performance showed a sensitivity of 98.1%, a specificity of 95.7%, a positive predictive value of 94.5%, a negative predictive value of 98.5%, and an AUC of 0.969. In the ≥14-mg/mL threshold scenario, the sensitivity was 98.1%, the specificity was 87.1%, the positive predictive value was 85.2%, the negative predictive value was 98.4%, and the AUC was 0.926. Conclusions: The calprotectin POC test has excellent PJI diagnostic characteristics, including high sensitivity and specificity in patients undergoing revision TKA. This test could be effectively implemented as a rule-out test. However, further investigations with larger cohorts are necessary to validate these results. Level of Evidence: Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

2 February 2022 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
JWJared A. Warren
Jared A. Warren
AKAlison K. Klika
Alison K. Klika
KBKathleen Bowers
Kathleen Bowers
JCJessica M. Colon-Franco
Jessica M. Colon-Franco
NPNicolas S. Piuzzi
Nicolas S. Piuzzi
CHCarlos A. Higuera
Carlos A. Higuera

7 April 2021 in The Journal of Applied Laboratory Medicine
Verified
Journal Article
Open access
PDF file
APAlexis Plaga
Alexis Plaga
RWRuhan Wei
Ruhan Wei
EOElizabeth Olson
Elizabeth Olson
DPDrew Payto
Drew Payto
JHJohn Harrington
John Harrington
JCJessica M. Colon-Franco
Jessica M. Colon-Franco
Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serological assays have emerged as a response to the global pandemic, warranting studies evaluating their clinical performance. This study investigated 7 commercially available SARS-CoV-2 serological assays in samples from noninfected individuals and hospitalized patients. Methods: SARS-CoV-2 qualitative serological assays by Abbott (IgG), Beckman (IgG), DiaSorin (IgG), EUROIMMUN (IgG and IgA), Roche and Bio-Rad (Total) were evaluated using specimens collected pre-December 2019 (n = 393), from nucleic acid amplification testing (NAAT) negative patients (n = 40), and from 53 patients with COVID-19 by NAAT collected 3–21 days post-onset of symptoms (POS) (N = 83). Negative agreement (NA), positive agreement (PA), and positive and negative predictive values (PPV and NPV) at prevalences of 5% and 10% were calculated. Results: The overall %NA; 95% CI in the negative samples were: Roche 99.8%; 99.3–100.2, Beckman 99.8%; 98.7–100.0, Abbott and Bio-Rad 99.3%; 98.0–99.9, DiaSorin 98.4; 97.2–99.6, EUROIMMUN IgG 97.5%; 95.5–98.7, and EUROIMMUN IgA 79.7%; 75.9–83.5), accounting for positive/equivocal results as false positives. The %PA; 95% CI in samples collected 14+ days POS (n = 24) were: Bio-Rad 83.3%; 68.4–98.2, Abbott and Roche 79.2%; 62.9–95.4, EUROIMMUN IgA 70.8%; 52.6–89.0, Beckman 58.3%; 38.6–78.1, DiaSorin 54.2; 34.2–74.1, and EUROIMMUN IgG 50.0%; 30.0–70.0, accounting for negative/equivocal results as false negatives. NPVs ranged from 97.4%–98.9% and 94.7%–97.7% for prevalences 5% and 10%, respectively. PPVs ranged from 15.5%–94.8% and 27.9%–97.4% for prevalences 5% and 10%, respectively. Conclusion: The Roche and Beckman assays resulted in fewer false positives, followed by the Bio-Rad and Abbott assays. While the Bio-Rad assay demonstrated higher antibody detection in COVID-19-positive patients, PA claims cannot be established with a high level of confidence in our sample population.

1 November 2023 in Journal of Mass Spectrometry and Advances in the Clinical Lab
Verified
Journal Article
Open access
JCJessica M. Colon-Franco
Jessica M. Colon-Franco
RMRogers A. Muldrow
Rogers A. Muldrow
WCWendy Cieslak
Wendy Cieslak
PDPatrick DeArmond
Patrick DeArmond
COCody Orahoske
Cody Orahoske
DBDustin Bunch
Dustin Bunch
Reliable lead screening methods are necessary to support early identification of lead exposure in children. Sample collection using dried blood spots (DBS) offers advantages compared to traditional venipuncture and capillary collection. Here, we describe and compare three lead DBS inductively coupled plasma-mass spectrometry (ICP-MS) methods for lead screening. Lead was extracted from Whatman 903 protein saver cards punches and analyzed by ICP-MS across three independent clinical laboratories. Each laboratory evaluated the performance of aqueous and matrix-matched DBS calibrators using external quality control samples (WI State of Laboratory of Hygiene Program). Leftover patient samples (n = 39) were used for an interlaboratory comparison of lead DBS. Lead DBS results were compared to whole blood methods. The DBS ICP-MS methods using matrix-matched DBS calibrators had superior performance to the aqueous calibrations. There was a strong correlation between lead measured in DBS (matrix-matched) and whole blood for the three methods evaluated. Lead can be measured accurately by ICP-MS in DBS samples when matrix-matched calibrators are used. External quality control programs are valuable to assess the performance of DBS methods. DBS lead ICP-MS methods are a robust analytical option for lead screening even though the limitations of DBS are well recognized.

1 October 2019 in Clinical Chemistry
Verified
Journal Article
Closed access
PDF file
AFAyesha Farooq
Ayesha Farooq
ATAngela Treml
Angela Treml
JCJessica M. Colon-Franco
Jessica M. Colon-Franco

17 August 2024 in American Journal of Clinical Pathology
Verified
Journal Article
Closed access
PDF file
SZSarah Zilka
Sarah Zilka
RWRuhan Wei
Ruhan Wei
DPDrew Payto
Drew Payto
KDKelly Doyle
Kelly Doyle
JHJennifer Hockings
Jennifer Hockings
JCJessica M. Colon-Franco
Jessica M. Colon-Franco
Objectives: This study determined the performance characteristics of a quantitative glucose-6-phosphate dehydrogenase (G6PD) assay with automated lysis and evaluated the robustness of the operational workflow following implementation in a hospital laboratory. Methods: The G6PD activity was measured in whole blood using an enzymatic quantitative test on a Roche cobas c501 analyzer with onboard lysis configuration and normalized to hemoglobin (Hb). The performance characteristics of the method and stability of G6PD in whole blood collected in EDTA-containing tubes were evaluated, and the reference interval was established on a population of healthy individuals (n = 279). The robustness of this automated workflow for sample lysis was evaluated during validation and after implementation for routine clinical use for 18 months and in 2,181 patients. Results: The G6PD assay was linear from 0.7 to 16.5 U/g Hb. Inter- and intra-assay precision using control and patient samples was below 12%. The G6PD results correlated well with a reference laboratory method (r = 0.96, y = 0.9615x – 1.222). The reference interval in our population was 9.8 to 15.5 U/g Hb. There were no interferences by lipemia and icteria, although grossly hemolyzed specimens may be affected. The testing workflow requires analyzing samples within minutes from mixing and loading into the instrument to avoid sample sedimentation. Measures to repeat samples with Hb 8.0 g/dL or less identified sedimented samples. In our patient population, 10.6% and 5.8% of the total males and females tested were G6PD deficient, respectively. Conclusions: The G6PD assay with automated lysis is acceptable for patient testing. Several measures ensured the robustness of this workflow in a hospital laboratory.