Konstantinos Sideris

Dr. Konstantinos Sideris


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2021 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
SVStephanie Voss
Stephanie Voss
CCCaterina Campanella
Caterina Campanella
MBMelchior Burri
Melchior Burri
TTTeresa Trenkwalder
Teresa Trenkwalder
KSKonstantinos Sideris
Konstantinos Sideris
RLRüdiger Lange
Rüdiger Lange
Background The dual-filter Sentinel™ Cerebral Protection System (Sentinel-CPS) is increasingly used during transcatheter aortic valve replacement (TAVR). However, complex vascular anatomy may challenge Sentinel-CPS deployment. Aim of the study We sought to investigate the impact of anatomic features of the aortic arch and the supra-aortic arteries on technical device failure of Sentinel-CPS application. Methods Analysis of the multislice computed tomography pre-TAVR aortograms of all patients undergoing TAVR with Sentinel-CPS between 2016 and 2020 (n = 92) was performed. We investigated the impact of aortic arch anatomy, configuration, and the angles of the supra-aortic arteries, including the determination of vascular tortuosity index on device failure of Sentinel-CPS application. Results The Sentinel-CPS was applied successfully in 83 patients (90.2%). Device failure in nine patients (9.8%) was due to the infeasibility to perform correct deployment of both filters (n = 7) and to obtain peripheral radial access (n = 2). Patients with a failure of Sentinel-CPS application had a higher right subclavian tortuosity index (217 [92–324] vs. 150 [42–252], p = .046), a higher brachiocephalic tortuosity index (27 [5–51] vs. 10 [0–102], p = 0.033) and a larger angulation of the brachiocephalic artery (59° [22–80] vs. 39° [7–104], p = .014) compared with patients with successful application. A brachiocephalic angle more than 59° was predictive for device failure. No differences in aortic arch anatomy or common carotid artery tortuosity were detected between the groups. Conclusions Brachiocephalic tortuosity was found to be associated with failure of Sentinel-CPS application. Filter-based usage should be avoided in TAVR patients with a brachiocephalic angle more than 59°.

23 January 2021 in Journal of Cardiac Surgery
Verified
Journal Article
Open access
PDF file
SVStephanie Voss
Stephanie Voss
AEAnnick Ernst
Annick Ernst
MEMagdalena Erlebach
Magdalena Erlebach
HRHendrik Ruge
Hendrik Ruge
KSKonstantinos Sideris
Konstantinos Sideris
NMN. Patrick Mayr
N. Patrick Mayr
Purpose The Sentinel Cerebral Protection System (Sentinel‐CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel‐CPS inside the brain‐supplying arteries on cerebral perfusion and oxygenation is unknown. Methods Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel‐CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2) was continuously measured with near‐infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel‐CPS insertion, filter positioning, and device retraction were analyzed. Results There was no significant difference in cumulative cerebral desaturation in patients with Sentinel‐CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel‐CPS, n = 3 without Sentinel‐CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel‐CPS insertion, filter positioning, or retraction. Conclusion Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel‐CPS. Catheter‐ and filter‐based manipulations in the brain‐supplying arteries for Sentinel‐CPS application were not associated with a decrease of cerebral perfusion and oxygenation.

18 January 2018 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
KSKonstantinos Sideris
Konstantinos Sideris
JVJanez Vodiskar
Janez Vodiskar
RLRuediger Lange
Ruediger Lange
JCJulie Cleuziou
Julie Cleuziou
Persistent right valve of the systemic venous sinus is a rare anomaly with anatomical variations. This anomaly may present as an obstructive structure that can inhibit the antegrade flow through the tricuspid valve. We report on a 4-day-old neonate who presented with pronounced peripheral and central cyanosis. Echocardiographic examination showed a giant Eustachian valve moving towards the tricuspid valve during late systole and leading to complete obstruction of the inflow. Blood flow was redirected through the persistent foramen ovale, producing a right-to-left shunt.

Verified
Journal Article
Open access
PDF file
KSKonstantinos Sideris
Konstantinos Sideris
MBMelchior Burri
Melchior Burri
AMAntonia Mayr
Antonia Mayr
SVStephanie Voss
Stephanie Voss
KVKeti Vitanova
Keti Vitanova
RGRalf Guenzinger
Ralf Guenzinger
Objectives: The optimal surgical approach for the treatment of functional mitral regurgitation (FMR) remains controversial. Current guidelines suggest that the surgical approach has to be tailored to the individual patient. The aim of the present study was to clarify further aspects of this tailored treatment. Methods: From 01/2006 to 12/2015, 390 patients underwent mitral valve (MV) surgery for FMR (ischemic n = 241, non-ischemic n = 149) at our institution. A regression analysis was used to determine the effect of MV repair or replacement on survival. The patients were analyzed according to the etiology of the MR (ischemic or non-ischemic), different age groups (75 years), LV function, and LV dimensions, as well as the underlying heart rhythm. Results: The overall survival rates for the repair group at 1, 5, and 8 years were 86.1 ± 1.9%, 70.6 ± 2.6%, and 55.1 ± 3.1%, respectively. For the same intervals, the survival rates in patients who underwent MV replacement were 75.9 ± 4.5%, 58.6 ± 5.4%, and 40.9 ± 6.4%, respectively (p = 0.003). Patients younger than 65 years, with an ischemic etiology of FMR, poor ejection fraction ( 60mm), and presence of atrial fibrillation had significantly higher mortality rates after MV replacement (HR, 3.0; CI, 1.3–6.9; p = 0.007). Patients between 65 and 75 years of age had a higher risk of death when undergoing mitral valve replacement (HR, 1.7; CI, 1.0–2.8; p = 0.04). In patients older than 75 years, the surgical approach (MV repair or replacement) had no effect on postoperative survival (HR, 0.8; CI, 0.4–1.3; p = 0.003). Conclusions: Our data demonstrate that, in patients younger than 65 years, the treatment of choice for FMR should be MV repair. This advantage was even more evident in patients with an ischemic origin of MR, a poor ejection fraction, a severe LV dilatation, and atrial fibrillation.

15 May 2019 in The Thoracic and Cardiovascular Surgeon
Verified
Journal Article
Closed access
PDF file
SVStephanie Voss
Stephanie Voss
MDMarcus-André Deutsch
Marcus-André Deutsch
JSJohanna Schechtl
Johanna Schechtl
MEMagdalena Erlebach
Magdalena Erlebach
KSKonstantinos Sideris
Konstantinos Sideris
SBSabine Bleiziffer
Sabine Bleiziffer
Background There is a growing use of cerebral protection devices in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to analyze if the use of these devices itself has an impact on the complexity and the risk of TAVR. Methods Between February 2016 and July 2017, 391 patients underwent transfemoral TAVR with Medtronic CoreValve Evolut R (n = 196) or Edwards Sapien 3 (n = 195). In 39 patients, the Claret Sentinel™ embolic protection device (CS-EPD) was used. Prospectively collected data were retrospectively analyzed, comparing fluoroscopy/operation time, amount of contrast used, vascular events, and postprocedural renal function in TAVR patients with (n = 39) and without (n = 352) CS-EPD. Results The CS-EPD was placed through the right radial (n = 35) or brachial (n = 4) artery. Procedural success rate defined as correct deployment and retraction of both filters was 94.9%. No device-related vascular complications occurred. TAVR patients with CS-EPD showed a significantly higher total operation time, total fluoroscopy time, and amount of used contrast (85.4 ± 39.3 vs. 64 ± 29.8 minutes, p = 0.002; 20.7 ± 9.3 vs. 13.7 ± 7 minutes, p ≤ 0.001; 133.7 ± 42.6 vs. 109.7 ± 44.5 mL, p = 0.001). Comparing the initial third of patients receiving a CS-EPD with the last third of CS-EPD cases, procedural time had decreased significantly (102.5 ± 34.9 vs. 67 ± 11.9; p = 0.002). There were no differences in postprocedural renal failure (p = 0.80). Conclusion Our data add evidence that the application of the CS-EPD is not associated with an additional risk for the patient. Although procedural time and amount of contrast are still higher when using the CS-EPD, there were no device-related complications or increased incidence of renal failure.

1 March 2019 in Metabolism Open
Verified
Journal Article
Open access
MSMaria Salourou
Maria Salourou
SAStefanos Archontakis
Stefanos Archontakis
SSSkevos Sideris
Skevos Sideris
IPIoannis Parisis
Ioannis Parisis
GSGerasimos Siasos
Gerasimos Siasos
DTDimitrios Tousoulis
Dimitrios Tousoulis
Dietary patterns may play an important role in the prognosis of heart failure. Dietary habits, sleeping habits, physical activity and anxiety and depression status were recorded in 326 patients (90 females, mean age 73.45 ± 10.9 years) with ischemic heart failure prospectively followed for 30 months. Lower ΗADS-depression scores (p = 0.03), a low-fat meat diet (p = 0.035) and moderate coffee consumption (p = 0.005) were associated with better prognosis. Non-significant differences were recorded in outcomes with regard to consumption of other dietary categories. A balanced diet as well as emphasis on the treatment of depression may improve outcomes in ischemic heart failure.