haymanot takele Mekonnen

haymanot takele Mekonnen


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2024 in Heliyon
Verified
Journal Article
Open access
ABAdugnaw Ayalew Bekele
Adugnaw Ayalew Bekele
HMhaymanot takele Mekonnen
haymanot takele Mekonnen
BYBelete Sirahbizu Yigezu
Belete Sirahbizu Yigezu
ANAbyot Yassab Nega
Abyot Yassab Nega
Natural fiber-reinforced polymer composites are the most widely used materials and preferable in terms of biodegradability, cost production, recyclability, and low density. The main aim of this study is to conduct an experimental investigation on tensile strength and impact strength of palmyra palm leaf stalk fiber (PLSF) and sisal fiber reinforced polymer hybrid composite. The composite material was fabricated using hand lay-up techniques. The working parameters are mass fraction ratio of PLSF/sisal fiber and volume fiber fraction with the matrix. Tensile strength and impact energy resistance tests were experimentally conducted according to the ASTM standard dimensions. The results revealed that the addition of sisal fiber to PLSF enhanced the tensile strength by 12.850 %, 26.540 %, and 30.630 % respectively compared to pure Palmyra palm leaf stalk fiber reinforced composite (PPFRC). Whereas, the addition of PLSF to sisal fiber improved the impact of energy by 20.980 %, 13.610 %, and 11.880 % compared to pure sisal fiber reinforced composite (PSFRC). The tensile strength with 20 % fiber volume fraction is improved by 53.996 % and 12.188 % compared to 10 % and 15 % of fiber respectively. The impact strength was also enhanced by 24.931 % and 10.030 % compared to 10 % and 15 % of volume fiber fraction respectively. The tensile strength and impact energy of the treated fiber composite increased by 62.243 % and 22.478 % respectively compared to the untreated hybrid Palmyra palm leaf stalk and sisal hybrid fiber reinforced composite (UHPSFRC). Generally, the HPSFRC-2 (Palmyra palm leaf stalk/sisal fiber) (P/S ratio 50/50 % ratio with 20/80 % ratio of fiber/matric percentage reinforced polymer hybrid composite) has good tensile strength and impact energy. Therefore, the mechanical property of the (Palm/Sisal) hybrid composite can be used for the manufacturing of the automotive interior parts like door panel, dash board, seat back, and automotive roof.

26 September 2022 in Scientific Programming
Verified
Journal Article
Open access
PDF file
Ayodeji Olalekan SalauAyodeji Olalekan Salau
Ayodeji Olalekan Salau
HMhaymanot takele Mekonnen
haymanot takele Mekonnen
Washing machines (WMs) are common household appliances that help to save time and effort used in brushing and washing clothes. It is a common practice to use manually operated WMs, and based on their uses, WMs are classified into top and front open cloth washing machines, which operate based on an automatic control mechanism. In this paper, we present the design and simulation of an Arduino fuzzy logic-based WM control system, with an emphasis on improvement in its operating algorithm. Simulations were performed to determine the optimal time the WM takes to wash clothes, the maximum number of clothes the WM can wash per time, the acceptable dirtiness level of cloths, and the type of clothes that the machine can wash. The number of clothes to be washed, the degree of dirtiness, and the type of clothes govern the fuzzy logic control process adopted by the WM. The output voltage of the WM varies as the degree of dirtiness of the water varies from 0 to 1.95 V for very dirty water output from washed clothes and varies from 4 to 4.89 V for low-contaminated water. Another constraint considered was the load current, which increased as the number of clothes increased. The WM’s operation time is determined by the amount of voltage and load current used during its operation. As a result, the control of the WM is dependent on the dirtiness level of the clothes and the amount of load.

9 November 2021 in Research Square
Verified
Preprint
Open access
PDF file
HMhaymanot takele Mekonnen
haymanot takele Mekonnen
BackgroundOne of the new technologies in generating power near the distribution system is called distributed generation which has supportive and destructive characteristics to the power system protection. One of the destructive characteristics of distributed generation is increasing the level of fault current to the protective equipment of the power system. In addition to increment of fault, it also alters the radial nature of the power distribution system and cause the power bidirectional rather than unidirectional. Integration of distributed generation to the distribution network causes increment of fault current effect, reliability drop, and affects security of protection system. The level of failure of protection be contingent on type, size, location and number of distributed generation. This fault current can cause a great damage to the electrical equipment with the miss operations of protective devices. The main aim of this paper is analysis of the fault current level to the protection of distribution network due to the integration of distributed generation which concerns on solar distributed generation, wind distributed generation and combination of solar and wind distributed generations at a time. This paper conducts the analysis for the increment of fault current by the integration of distributed generation and its impact on distribution network protection. ResultsThe analysis and the modeling are conducted on the 15KV distribution network of the radial feeder in Debre Markos town. This paper has covered the ling to ground, line to line and three phase fault analysis and their impact on the protection of distribution system for the wind and solar distributed generation types. After the integration of the distributed generation the fault current is increased by 0.529KA for three phase, 0.74KA for line to ground, 0.467KA for line to line and 0.523KA for line to line to ground. ConclusionsThis paper confirms designing distribution network without forecasting the future demand of electric power users give the protection equipment additional requirement. As the result, the fault current after the integration of distributed generation to the distribution network have great value in terms of power system protection.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
HMhaymanot takele Mekonnen
haymanot takele Mekonnen
Integration of Distributed Generation (DG) generate problems for the protection of Distribution Networks (DNs) in power systems. When DG is integrated into a power distribution system (DS), the radial nature of the network is altered and the power starts to flow in a reverse direction. In addition to the reverse flow of power, the DG upsurges the fault current level which affects the existing time intermission coordination of the protective overcurrent relay. This study proposes a reverse power relay (RPR) and Fault Current Limiter (FCL) to mitigate the fault current level and reverse power flow in a Distribution Network (DN) by the use of DG. The FCL works only as unidirectional fault current limiter (UFCL) by restricting the flow of fault current that occurs in the main grid (MG) of the DG. However, FCLs can protect the flow of fault currents from the MG by affecting the operational flexibility and reliability of the DG. To overcome the flow of fault current of the DG, this study proposes RPR to monitor the power flow to the DG. Collectively the study focuses on the protection of radial DS by using RPR and UFCL. The analysis and the modeling was conducted on the 15KV DN of the radial feeder in Debre Markos DN. The 3Φ fault analysis (which is severe than others) was performed to validate the protection capability of the mitigation techniques which were proposed in this study.