Photoplethysmographic (PPG) pulses contain information about cardiovascular parameters. In particular, blood pressure can be estimated using PPG pulse decomposition analysis, which assumes that a PPG pulse is composed of the original heart ejection blood wave and its reflections in arterial branchings. Among pulse decomposition wave functions that have been studied in the literature, Gaussian waves are the most successful ones. However, a more adequate pulse decomposition function could be found to improve blood pressure estimates. In this paper, we propose pulse decomposition analysis using hyperbolic secant (sech) waves and compare results with corresponding Gaussian wave decomposition. We analyze how the parameters of each of the two types of decomposition waves correlate with blood pressure. For this analysis, continuous blood pressure data and PPG data were acquired from ten healthy volunteers. The blood pressure of volunteers was varied by asking them to hold their breath for up to 60 s. The results suggested sech wave decomposition had higher accuracy in estimating blood pressure than the Gaussian function. Thus, sech wave decomposition should be considered as a more robust alternative to Gaussian wave pulse decomposition for blood pressure estimation models.
A fotopletismografia (PPG) é uma técnica utilizada na monitoração da saturação de oxigênio (SpO2) e frequência cardíaca. A medição da pressão arterial é convencionalmente feita utilizando o esfigmomanômetro (EM). O EM, além de depender da oclusão de um membro não é possível de realizar a medida de forma contínua. Através da Análise da Decomposição do pulso de PPG foi demonstrado que é possível determinar a Pressão Arterial, através da determinação do Tempo de Trânsito do pulso sanguíneo (PTT). Entretanto, a decomposição em pulsos gaussianos, Rayleigh e Log-Normal sugeridas na literatura geram grandes incertezas na determinação de PTT. Para diminuir tais incertezas, sugerimos como hipótese o uso da decomposição da curva de PPG em pulsos do tipo secante hiperbólica. Analisamos 20 curvas de PPG para nove voluntários com idades de 20 a 50 anos. Utilizamos minimização de Qui-quadrado e o critério de Akaike para avaliação dos resultados. A decomposição em pulsos do tipo secante hiperbólica reduziu a incerteza relativa na determinação do PTT em cerca de 50%, em relação ao padrão da literatura que é a decomposição em pulsos gaussianos. Para determinação de pressão arterial através de PPG, essa redução na incerteza permite resposta quatro vezes mais rápida na medida de variações de pressão arterial, para uma dada resolução.Palavras-chave: Pressão Arterial, Pletismografia, Monitoramento não invasivo, Análise de Decomposição de pulso
In this article, we investigate the spectral properties of light and RGB systems that optimize precision for spectral quantification of chromophores melanin, oxyhemoglobin, and deoxyhemoglobin in skin images. The methodology uses the Beer-Lambert law, and the stability of the resultant system of equations is studied regarding spectral properties of the RGB channels plus illuminant. Good backward reconstruction of the image and low condition number for the linear system matrix predict that spectral parameter chosen to decompose the image in the absence of spectroscopy knowledge about the system and camera are adequate.
Skin color observation provides a simple and non-invasive method to estimate the health status of patients. Capillary Refill Time (CRT) is widely used as an indicator of pathophysiological conditions, especially in emergency patients. While the measurement of CRT is easy to perform, its evaluation is highly subjective. This study proposes a method to aid quantified CRT measurement using an RGB camera. The procedure consists in applying finger compression to the forearm, and the CRT is calculated based on the skin color change after the pressure release. We estimate compression applied by a finger from its fingernail color change during compression. Our study shows a step towards camera-based quantitative CRT for untrained individuals.
Capillary Refill Time (CRT) assesses peripheral perfusion in resource-limited settings. However, the repeatability and reproducibility of CRT measurements are limited for individuals with darker skin. This paper presents quantitative CRT measurements demonstrating good performance and repeatability across all Fitzpatrick skin phototypes. The study involved 22 volunteers and utilized controlled compression at 7 kPa, an RGB video camera, and cocircular polarized white LED light. CRT was determined by calculating the time constant of an exponential regression applied to the mean pixel intensity of the green (G) channel. An adaptive algorithm identifies the optimal regression region for noise reduction, and flags inappropriate readings. The results indicate that 80% of the CRT readings fell within a 20% range of the expected CRT value. The repetition standard deviation was 17%. These findings suggest the potential for developing reliable and reproducible quantitative CRT methods for robust measurements in patient triage, monitoring, and telehealth applications.