Diego Arcos Avilés

Prof. Dr. Diego Arcos Avilés

Universidad de las Fuerzas Armadas ESPE, Sangolquí, Pichincha, Ecuador
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Diego Arcos AvilésDiego Arcos Avilés
Diego Arcos Avilés
JPJulio Pascual
Julio Pascual
LMLuis Marroyo
Luis Marroyo
PSPablo Sanchis
Pablo Sanchis
FGFrancesc Guinjoan
Francesc Guinjoan
This paper presents the design of a low complexity fuzzy logic controller of only 25-rules to be embedded in an energy management system for a residential grid-connected microgrid including renewable energy sources and storage capability. The system assumes that neither the renewable generation nor the load demand is controllable. The main goal of the design is to minimize the grid power profile fluctuations while keeping the battery state of charge within secure limits. Instead of using forecasting-based methods, the proposed approach use both the microgrid energy rate-of-change and the battery state of charge to increase, decrease, or maintain the power delivered/absorbed by the mains. The controller design parameters (membership functions and rule-base) are adjusted to optimize a pre-defined set of quality criteria of the microgrid behavior. A comparison with other proposals seeking the same goal is presented at simulation level, whereas the features of the proposed design are experimentally tested on a real residential microgrid implemented at the Public University of Navarre.

1 November 2017 in Applied Energy
Verified
Journal Article
Open access
Diego Arcos AvilésDiego Arcos Avilés
Diego Arcos Avilés
JPJulio Pascual
Julio Pascual
FGFrancesc Guinjoan
Francesc Guinjoan
LMLuis Marroyo
Luis Marroyo
PSPablo Sanchis
Pablo Sanchis
MMMartin P. Marietta
Martin P. Marietta
This paper presents the design of an energy management strategy based on a low complexity Fuzzy Logic Control (FLC) for grid power profile smoothing of a residential grid-connected microgrid including Renewable Energy Sources (RES) and battery Energy Storage System (ESS). The proposed energy management strategy uses generation and demand forecasting to anticipate the future behavior of the microgrid. Accordingly to the microgrid power forecast error and the Battery State-of-Charge (SOC) the proposed strategy performs the suitable control of the grid power. A simulation comparison with previous energy management strategies highlights the advantages of the proposed work minimizing fluctuations and power peaks in the power profile exchanged with the grid while keeping the energy stored in the battery between secure limits. Finally, the experimental validation in a real residential microgrid implemented at Public University of Navarre (UPNa, Spain) demonstrates the proper operation of the proposed strategy achieving a smooth grid power profile and a battery SOC center close to the 75% of the rated battery capacity.Peer ReviewedPostprint (author's final draft

10 February 2023 in Applied Energy
Verified
Journal Article
Closed access
MRMauricio Rodriguez
Mauricio Rodriguez
Diego Arcos AvilésDiego Arcos Avilés
Diego Arcos Avilés
WMWilmar Martinez
Wilmar Martinez

2 February 2021 in IEEE Access
Verified
Journal Article
Open access
Diego Arcos AvilésDiego Arcos Avilés
Diego Arcos Avilés
JPJulio Pascual
Julio Pascual
FGFrancesc Guinjoan Gispert
Francesc Guinjoan Gispert
LMLuis Marroyo
Luis Marroyo
GGGabriel Garcia-Gutierrez
Gabriel Garcia-Gutierrez
TMT. Emilia Motoasca
T. Emilia Motoasca
This work deals with the design of a Fuzzy Logic Control (FLC) based Energy Management System (EMS) for smoothing the grid power profile of a grid-connected electro-thermal microgrid. The case study aims to design an Energy Management System (EMS) to reduce the impact on the grid power when renewable energy sources are incorporated to pre-existing grid-connected household appliances. The scenario considers a residential microgrid comprising photovoltaic and wind generators, flat-plate collectors, electric and thermal loads and electrical and thermal energy storage systems and assumes that neither renewable generation nor the electrical and thermal load demands are controllable. The EMS is built through two low-complexity FLC blocks of only 25 rules each. The first one is in charge of smoothing the power profile exchanged with the grid, whereas the second FLC block drives the power of the Electrical Water Heater (EWH). The EMS uses the forecast of the electrical and thermal power balance between generation and consumption to predict the microgrid behavior, for each 15-minute interval, over the next 12 hours. Simulations results, using real one-year measured data show that the proposed EMS design achieves 11.4% reduction of the maximum power absorbed from the grid and an outstanding reduction of the grid power profile ramp-rates when compared with other state-of-the-art studies.

1 August 2021 in Applied Energy
Verified
Journal Article
Open access
JPJulio Pascual
Julio Pascual
Diego Arcos AvilésDiego Arcos Avilés
Diego Arcos Avilés
AUAlfredo Ursúa
Alfredo Ursúa
PSPablo Sanchis
Pablo Sanchis
LMLuis Marroyo
Luis Marroyo

8 December 2020 in IEEE Transactions on Signal Processing
Verified
Journal Article
Closed access
BZBakht Zaman
Bakht Zaman
LRLuis Miguel Lopez Ramos
Luis Miguel Lopez Ramos
DRDaniel Romero
Daniel Romero
BBBaltasar Beferull-Lozano
Baltasar Beferull-Lozano
Causality graphs are routinely estimated in social sciences, natural sciences, and engineering due to their capacity to efficiently represent the spatiotemporal structure of multivariate data sets in a format amenable for human interpretation, forecasting, and anomaly detection. A popular approach to mathematically formalize causality is based on vector autoregressive (VAR) models and constitutes an alternative to the well-known, yet usually intractable, Granger causality. Relying on such a VAR causality notion, this paper develops two algorithms with complementary benefits to track time-varying causality graphs in an online fashion. Their constant complexity per update also renders these algorithms appealing for big-data scenarios. Despite using data sequentially, both algorithms are shown to asymptotically attain the same average performance as a batch estimator which uses the entire data set at once. To this end, sublinear (static) regret bounds are established. Performance is also characterized in time-varying setups by means of dynamic regret analysis. Numerical results with real and synthetic data further support the merits of the proposed algorithms in static and dynamic scenarios.