Luis Marroyo

Dr. Luis Marroyo


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2011
Verified
Book
Open access
GAGonzalo Abad
Gonzalo Abad
JLJesús López
Jesús López
MRMiguel A. Rodríguez
Miguel A. Rodríguez
LMLuis Marroyo
Luis Marroyo
Grzegorz IwanskiGrzegorz Iwanski
Grzegorz Iwanski
Click on the title to browse this book

5 March 2007 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
RGRoberto Gonzalez
Roberto Gonzalez
JLJess Lopez
Jess Lopez
PSPablo Sanchis
Pablo Sanchis
LMLuis Marroyo
Luis Marroyo
When no transformer is used in a grid-connected photovoltaic (PV) system, a galvanic connection between the grid and the PV array exists. In these conditions, dangerous leakage currents (common-mode currents) can appear through the stray capacitance between the PV array and the ground. In order to avoid these leakage currents, different inverter topologies that generate no varying common-mode voltages, such as the half-bridge and the bipolar pulsewidth modulation (PWM) full-bridge topologies, have been proposed. The need of a high-input voltage represents an important drawback of the half-bridge. The bipolar PWM full bridge requires a lower input voltage but exhibits a low efficiency. This letter proposes a new high-efficiency topology that generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full bridge. The proposed topology has been verified in a 5-kW prototype with satisfactory results

29 November 2010 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JAJuan Luis Agorreta
Juan Luis Agorreta
MBMikel Borrega
Mikel Borrega
JLJesús López
Jesús López
LMLuis Marroyo
Luis Marroyo
Designing adequate control laws for grid-connected inverters with LCL filters is complicated. The power quality standards and the system resonances burden the task. In order to deal with resonances, system damping has to be implemented. Active damping is preferred to passive damping so as to improve the efficiency of the conversion. In addition, paralleled grid-connected inverters in photovoltaic (PV) plants are coupled due to grid impedance. Generally, this coupling is not taken into account when designing the control laws. In consequence, depending on the number of paralleled grid-connected inverters and the grid impedance, the inverters installed in PV plants do not behave as expected. In this paper, the inverters of a PV plant are modeled as a multivariable system. The analysis carried out enables to obtain an equivalent inverter that describes the totality of inverters of a PV plant. The study is validated through simulation and field experiments. The coupling effect is described and the control law design of paralleled grid-connected inverters with LCL filters in PV plants is clarified.

24 June 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RGRoberto Gonzalez
Roberto Gonzalez
EGEugenio Gubia
Eugenio Gubia
JLJesús Lopez
Jesús Lopez
LMLuis Marroyo
Luis Marroyo
The elimination of the output transformer from grid- connected photovoltaic (PV) systems not only reduces the cost, size, and weight of the conversion stage but also increases the system overall efficiency. However, if the transformer is removed, the galvanic isolation between the PV generator and the grid is lost. This may cause safety hazards in the event of ground faults. In addition, the circulation of leakage currents (common-mode currents) through the stray capacitance between the PV array and the ground would be enabled. Furthermore, when no transformer is used, the inverter could inject direct current (dc) to the grid, causing the saturation of the transformers along the distribution network. While safety requirements in transformerless systems can be met by means of external elements, leakage currents and the injection of dc into the grid must be guaranteed topologically or by the inverter's control system. This paper proposes a new high-efficiency topology for transformerless systems, which does not generate common-mode currents and topologically guarantees that no dc is injected into the grid. The proposed topology has been verified in a 5-kW prototype with satisfactory results.

20 August 2007 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
JLJesús López
Jesús López
PSPablo Sanchis
Pablo Sanchis
XRXavier Roboam
Xavier Roboam
LMLuis Marroyo
Luis Marroyo
The use of doubly fed induction generators (DFIGs) in large wind turbines has become quite common over the last few years. These machines provide variable speed and are driven with a power converter which is sized for a small percentage of the turbine-rated power. A drawback of the DFIG is that it is very sensitive to grid disturbances, especially to voltage dips. However, the operation of the machine in these situations has only been studied in the literature by means of simulations. This paper develops a theoretical analysis of the dynamic behavior of the induction machine during three-phase voltage dips. The proposed analysis contributes to understanding the causes of the problem and represents a very useful tool to improve the existing solutions and propose new alternatives. Experimental results are in good agreement with those obtained theoretically and validate the proposed analysis.

1 October 2009 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
JLJ. Lopez
J. Lopez
EGE. Gubia
E. Gubia
EOE. Olea
E. Olea
JRJ. Ruiz
J. Ruiz
LMLuis Marroyo
Luis Marroyo
This paper deals with the grid fault ride-through capability of doubly fed induction generators. These machines are very sensitive to grid disturbances. To prevent the damages that voltage dips can cause on the converter, most machines are equipped nowadays with a crowbar that short circuits the rotor. However, during the crowbar activation, the rotor converter must be disconnected, hence the power generated with the turbine is no longer controlled. In doing so, the crowbar impedes the wind turbine from carrying out the voltage stabilization required by most new grid codes. This paper proposes a novel control strategy that notably reduces the crowbar activation time. As a result, the control of the turbine might shortly be resumed and the turbine can furthermore supply a reactive power fulfilling the newest grid regulations. Experimental results of a complete system are included, demonstrating the viability of the proposed control.