Krishna Burugapalli

Dr. Krishna Burugapalli


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2012 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
BCBianmei Cao
Bianmei Cao
YZYudong Zheng
Yudong Zheng
TXTingfei Xi
Tingfei Xi
CZChuanchuan Zhang
Chuanchuan Zhang
WSWenhui Song
Wenhui Song
YMYanxuan Ma
Yanxuan Ma

1 February 2003 in Biomaterials
Verified
Journal Article
Closed access
MCMohammad Changez
Mohammad Changez
KBKrishna Burugapalli
Krishna Burugapalli
VKVeena Koul
Veena Koul
VCVeena Choudhary
Veena Choudhary

26 March 2010 in Nanotechnology
Verified
Journal Article
Closed access
ZZZhigang Zhu
Zhigang Zhu
WSWenhui Song
Wenhui Song
KBKrishna Burugapalli
Krishna Burugapalli
FMFrancis Moussy
Francis Moussy
YLYa-Li Li
Ya-Li Li
XZXiao-Hua Zhong
Xiao-Hua Zhong
A novel brush-like electrode based on carbon nanotube (CNT) nano-yarn fiber has been designed for electrochemical biosensor applications and its efficacy as an enzymatic glucose biosensor demonstrated. The CNT nano-yarn fiber was spun directly from a chemical-vapor-deposition (CVD) gas flow reaction using a mixture of ethanol and acetone as the carbon source and an iron nano-catalyst. The fiber, 28 microm in diameter, was made of bundles of double walled CNTs (DWNTs) concentrically compacted into multiple layers forming a nano-porous network structure. Cyclic voltammetry study revealed a superior electrocatalytic activity for CNT fiber compared to the traditional Pt-Ir coil electrode. The electrode end tip of the CNT fiber was freeze-fractured to obtain a unique brush-like nano-structure resembling a scale-down electrical 'flex', where glucose oxidase (GOx) enzyme was immobilized using glutaraldehyde crosslinking in the presence of bovine serum albumin (BSA). An outer epoxy-polyurethane (EPU) layer was used as semi-permeable membrane. The sensor function was tested against a standard reference electrode. The sensitivities, linear detection range and linearity for detecting glucose for the miniature CNT fiber electrode were better than that reported for a Pt-Ir coil electrode. Thermal annealing of the CNT fiber at 250 degrees C for 30 min prior to fabrication of the sensor resulted in a 7.5 fold increase in glucose sensitivity. The as-spun CNT fiber based glucose biosensor was shown to be stable for up to 70 days. In addition, gold coating of the electrode connecting end of the CNT fiber resulted in extending the glucose detection limit to 25 microM. To conclude, superior efficiency of CNT fiber for glucose biosensing was demonstrated compared to a traditional Pt-Ir sensor.

1 January 2013 in Biomaterials
Verified
Journal Article
Closed access
NWNing Wang
Ning Wang
KBKrishna Burugapalli
Krishna Burugapalli
WSWenhui Song
Wenhui Song
JHJustin Halls
Justin Halls
FMFrancis Moussy
Francis Moussy
YZYudong Zheng
Yudong Zheng

19 July 2001 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
KBKrishna Burugapalli
Krishna Burugapalli
DBDhiraj Bhatia
Dhiraj Bhatia
VKVeena Koul
Veena Koul
VCVeena Choudhary
Veena Choudhary

1 January 2013 in Journal of Membrane Science
Verified
Journal Article
Closed access
NWNing Wang
Ning Wang
KBKrishna Burugapalli
Krishna Burugapalli
WSWenhui Song
Wenhui Song
JHJustin Halls
Justin Halls
FMFrancis Moussy
Francis Moussy
KLKang Li
Kang Li