Mareike Warkentin

Prof. Dr. Mareike Warkentin


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2007 in Applied and Environmental Microbiology
Verified
Journal Article
Closed access
MWMareike Warkentin
Mareike Warkentin
HFHeike M. Freese
Heike M. Freese
UKUlf Karsten
Ulf Karsten
RSRhena Schumann
Rhena Schumann
A new method of respiration rate measurement based on oxygen luminescence quenching in sensor spots was evaluated for the first time for aquatic bacterial communities. The commonly used Winkler and Clark electrode methods to quantify oxygen concentration both require long incubation times, and the latter additionally causes signal drift due to oxygen consumption at the cathode. The sensor spots proved to be advantageous over those methods in terms of precise and quick oxygen measurements in natural bacterial communities, guaranteeing a respiration rate estimate during a time interval short enough to neglect variations in organism composition, abundance, and activity. Furthermore, no signal drift occurs during measurements, and respiration rate measurements are reliable even at low temperatures and low oxygen consumption rates. Both a natural bacterioplankton sample and a bacterial isolate from a eutrophic river were evaluated in order to optimize the new method for aquatic microorganisms. A minimum abundance of 2.2 × 10 6 respiring cells ml −1 of a bacterial isolate was sufficient to obtain a distinct oxygen depletion signal within 20 min at 20°C with the new oxygen sensor spot method. Thus, a culture of a bacterial isolate from a eutrophic river (OW 144; 20 × 10 6 respiring bacteria ml −1 ) decreased the oxygen saturation about 8% within 20 min. The natural bacterioplankton sample respired 2.8% from initially 94% oxygen-saturated water in 30 min. During the growth season in 2005, the planktonic community of a eutrophic river consumed between 0.7 and 15.6 μmol O 2 liter −1 h −1 . The contribution of bacterial respiration to the total plankton community oxygen consumption varied seasonally between 11 and 100%.

28 August 2021 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
DGD. C. Gornig
D. C. Gornig
RMR. Maletz
R. Maletz
POP. Ottl
P. Ottl
MWMareike Warkentin
Mareike Warkentin
Objective: The aim of the study was to evaluate the influence of filler content, degradation media and time on the mechanical properties of different dental composites after in vitro aging. Materials and Methods: Specimens (1 mm3) of three commercially available composites (GrandioSO®, Arabesk Top®, Arabesk Flow®) with respect to their filler content were stored in artificial aging media: artificial saliva, ethanol (60%), lactic acid (pH 5) and citric acid (pH 5). Parameters (Vickers microhardness, compressive strength, elastic modulus, water sorption and solubility) were determined in their initial state (control group, n = 3 for microhardness, n = 5 for the other parameters) and after 14, 30, 90 and 180 days (n = 3 for microhardness, n = 5 for the other parameters for each composite group, time point and media). Specimens were also characterized with dynamic-mechanical-thermal analysis (compression tests, F = ± 7 N; f = 0.5 Hz, 1 Hz and 3.3 Hz; t = 0–170 °C). Results: Incorporation of fillers with more than 80 w% leads to significantly better mechanical properties under static and dynamic compression tests and a better water sorption behavior, even after chemical degradation. The influence of degradation media and time is of subordinate importance for chemical degradation. Conclusion: Although the investigated composites have a similar matrix, they showed different degradation behavior. Since dentine and enamel occur only in small layer thickness, a test specimen geometry with very small dimensions is recommended for direct comparison. Moreover, the use of compression tests to determine the mechanical parameters for the development of structure-compatible and functionally adapted composites makes sense as an additional standard. Clinical relevance Preferential use of highly filled composites for occlusal fillings is recommended.


14 February 2019 in Coatings
Verified
Journal Article
Open access
PDF file
SNStefan Nißen
Stefan Nißen
JHJan Heeg
Jan Heeg
MWMarion Wienecke
Marion Wienecke
DBDetlef Behrend
Detlef Behrend
MWMareike Warkentin
Mareike Warkentin
patrick chaponpatrick chapon
patrick chapon
This paper focuses on the surface properties of a-C:H:Cu composite coatings for medical devices and how the release of Cu2+ ions from such coatings can be controlled. The released Cu ions have the potential to act as a bactericidal agent and inhibit bacterial colonization. A PVD–PECVD hybrid process was used to deposit a-C:H:Cu composite coatings onto Ti6Al4V substrates. We examine the layer surface properties using atomic force microscopy and static contact angle measurements. An increasing surface roughness and increasing contact angle of Ringer’s solution was measured with increasing copper mole fraction (XCu) in the coatings. The contact angle decreased when a supplementary bias voltage of −50 V was used during the a-C:H:Cu deposition. These findings are in line with earlier published results regarding these types of coatings. The release of Cu2+ ions from a-C:H:Cu coatings in Ringer’s solution was measured by anodic stripping voltammetry. Different layer structures were examined to control the time-resolved Cu release. It was found that the Cu release depends on the overall XCu in the a-C:H:Cu coatings and that an additional a-C:H barrier layer on top of the a-C:H:Cu layer effectively delays the release of Cu ions.

24 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
KWKatharina Witzke
Katharina Witzke
MFMarcus Frank
Marcus Frank
OSOlaf Specht
Olaf Specht
USUte Schulz
Ute Schulz
COClaudia Oehlschläger
Claudia Oehlschläger
MWMareike Warkentin
Mareike Warkentin
(1) Background: The aim of this study was to systematically compare TEM sections of mineralized human enamel and dentine prepared by focused ion beam (in situ lift-out) technique and ultramicrotomy through a combination of microscopic examination methods (scanning electron microscopy and transmission electron microscopy). In contrast with published studies, we compared the TEM preparation methods using the same specimen blocks as those for the ultramicrotomy and FIB technique. (2) Methods: A further evaluation of TEM sample preparation was obtained by confocal laser scanning microscopy and atomic force microscopy. In addition, ultramicrotome- and focused ion beam-induced artefacts are illustrated. (3) Results: The FIB technique exposed a major difference between non-decalcified enamel and dentine concerning the ultrastructural morphology compared to ultramicrotome-prepared sections. We found that ultramicrotomy was useful for cutting mineralized dentine, with the possibility of mechanical artefacts, but offers limited options for the preparation of mineralized enamel. FIB preparation produced high-quality TEM sections, showing the anisotropic ultrastructural morphology in detail, with minor structural artefacts. Our results show that the solution of artificial saliva and glutardialdehyde (2.5% by volume) is a very suitable fixative for human mineralized tissue. (4) Conclusions: The protocol that we developed has strong potential for the preparation of mineralized biomaterials for TEM imaging and analysis.

20 June 2022 in Molecules
Verified
Journal Article
Open access
PDF file
RBRichard Behnke
Richard Behnke
FSFranka Stahl
Franka Stahl
KDKathrin Duske
Kathrin Duske
MWMareike Warkentin
Mareike Warkentin
MSMargit Schwartz
Margit Schwartz
UWUdo I. Walther
Udo I. Walther
Depending on their composition, plastics have a cytotoxic potential that needs to be evaluated before they are used in dentistry, e.g., as orthodontic removable appliances. Relevant guidelines set out requirements that a potential new resin in the medical field must meet, with a wide scope for experimental design. In the present study, test specimens of different geometries consisting of varying polymers (Orthocryl®, Orthocryl® LC, Loctite® EA 9483, Polypropylene) were soaked for different periods of time, then transferred to cell culture medium for 24 h, which was subsequently used for 24-h cultivation of A549 cells, followed by cytotoxicity assays (WST-1, Annexin V-FITC-propidium iodide (PI) flow cytometry). In this context, a reduction in the cytotoxic effect of the eluates of test specimens prepared from Orthocryl® LC and Loctite® EA 9483 was particularly evident in the Annexin V-FITC-PI assay when the soaking time was extended to 48 h and 168 h, respectively. Consistent with this, a reduced release of potentially toxic monomers into the cell culture medium, as measured by gas chromatography-mass spectrometry, was observed when the prior soaking time of test specimens of all geometries was extended. Remarkably, a significant increase in cytotoxic effect was observed in the WST-1 assay, which was accompanied by a higher release of monomers when the thickness of the test sample was increased from 0.5 to 1.0 mm, although an elution volume adapted to the surface area was used. However, further increasing the thickness to 3.0 mm did not lead to an increase in the observed cytotoxicity or monomer release. Test specimens made of polypropylene showed no toxicity under all test specimen sizes and soaking time conditions. Overall, it is recommended to perform toxicity studies of test specimens using different geometries and soaking times. Thereby, the influence of the different specimen thicknesses should also be considered. Finally, an extension of the test protocols proposed in ISO 10993-5:2009 should be considered, e.g., by flow cytometry or monomer analysis as well as fixed soaking times.