Bronchoscopic lung-volume reduction with the use of one-way endobronchial valves is a potential treatment for patients with severe emphysema. To date, the benefits have been modest but have been hypothesized to be much larger in patients without interlobar collateral ventilation than in those with collateral ventilation.
Background: One-way endobronchial valve (EBV) treatment has shown safety and efficacy at 6 months after treatment in patients with severe emphysema and confirmed absence of interlobar collateral ventilation. Longer follow-up in this subgroup is not available. Objectives: To investigate the efficacy and safety of EBV treatment of the STELVIO cohort at a 1-year follow-up. Methods: Emphysema patients who have been treated with EBV in the STELVIO trial were invited for a voluntary 1-year follow-up visit. Both the original treatment group and the control group who crossed over to treatment have been included. Analyses are performed on the patients who attended the 1-year follow-up visit. Results: Sixty-four patients received EBV treatment. At 1 year, 40 patients (26 female; mean age 59 ± 8 years; FEV1 0.86 ± 0.29 L; RV 4.56 ± 1.00 L; 6MWD 367 ± 78 m; and SGRQ 56 ± 13 points) visited the hospital. Significant improvements (p < 0.001) were found for FEV1 (+17%, 95% CI, 11 to 24), RV (-687 mL, 95% CI, -918 to -456), 6MWD (+61 m, 95% CI, 42 to 80), and SGRQ (-11 points, 95% CI, −17 to −6). Two patients died: 1 after 58 days due to progressive respiratory failure and 1 after 338 days of follow-up due to a myocardial infarction. Seventeen percent of the patients underwent valve replacement and 22% of the initially treated patients had permanent valve removal. In 22% of the patients, pneumothoraces occurred before 6 months, and none occurred between 6 and 12 months. Conclusions: EBV treatment results in clinically relevant benefits at 1 year of follow-up. Maintenance bronchoscopies to achieve this are needed. This study supports the use of EBV treatment in carefully selected patients with severe emphysema without collateral ventilation.
1 June 2020 in International Journal of Chronic Obstructive Pulmonary Disease
Purpose: Lung volume reduction using one-way endobronchial valves is a bronchoscopic treatment for patients with severe emphysema without collateral ventilation between the treatment target lobe and the ipsilateral lobe(s). CT-scan fissure analysis is often used as a surrogate to predict the absence of collateral ventilation. We aimed to evaluate the predictive value of the fissure completeness score (FCS) compared to the functional Chartis measurement of collateral ventilation and to provide cut-off values of the FCS in patient selection. Patients and Methods: Multicenter study in patients eligible for treatment with one-way valves. The FCS was calculated by quantitative CT analysis (Thirona, the Netherlands) and compared to status of interlobar collateral ventilation measured with Chartis system (PulmonX, USA). Thresholds were calculated for the predictive values of the presence of collateral ventilation. Results: An FCS > 95% of the left major fissure had a positive predictive value (PPV) of 91%, with 1 in 11 fissures demonstrating collateral ventilation with Chartis measurement, whereas an FCS of ≤ 80% had a negative predictive value (NPV) of 100% for the presence of collateral ventilation. For the right major fissure, the NPV was 100% for an FCS ≤ 90%, but 69.7% for the right upper lobe fissure. Conclusion: Quantitative CT analysis is recommended in all patients evaluated for endobronchial valves. Patients with incomplete fissures (left major fissure: FCS < 80%; right major fissure: < 90%) can be excluded from Chartis measurement and endobronchial valve treatment. In patients with more complete fissures, the FCS is not specific enough for endobronchial valve treatment decisions. In this case, additional Chartis measurements are always recommended in the right lung. For the left lung, Chartis assessments may be omitted if the FCS is > 95%.
Background: Bronchoscopic lung volume reduction using endobronchial coils is a new treatment for patients with severe emphysema. To date, the benefits have been modest and have been suggested to be much larger in patients with severe hyperinflation and nonmulti-comorbidity. Objective: We aimed to evaluate the efficacy and safety of endobronchial coil treatment in a randomized multicenter clinical trial using optimized patient selection. Method: Patients with severe emphysema on HRCT scan with severe hyperinflation (residual volume [RV] ≥200% predicted and RV/total lung capacity [TLC] >55%) were randomized to coil treatment or control. Primary outcome measures were differences in the forced expiratory volume in 1 s (FEV1) and St George’s Respiratory Questionnaire (SGRQ) total score at 6 months. Results: Due to premature study termination, a total of 120 patients (age 63 ± 7 years, FEV1 29 ± 7% predicted, RV 251 ± 41% predicted, RV/TLC 67 ± 6%, and SGRQ 58 ± 13 points), instead of 210 patients, were randomized. At study termination, 91 patients (57 coil and 34 control) had 6-month results available. Analyses showed significantly greater improvements in favor of the coil group. The increase in FEV1 was greater in the coil group than that in the control group by + 10.3 [+4.7 to +16.0] % and in SGRQ by −10.6 [−15.9 to −5.4] points. At study termination, there were 5 (6.8%) deaths in the coil cohort reported. Conclusion: Despite early study termination, coil treatment compared to control results in a significant improvement in the lung function and quality of life benefits for up to 6 months in patients with emphysema and severe hyperinflation. These improvements were of clinical importance but were associated with a higher likelihood of serious adverse events.
Background: Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) is a valid therapy for severe emphysema patients. However, alpha-1 antitrypsin (AAT)-deficient patients were excluded from the majority of clinical trials investigating this intervention. Objectives: The aim of this study was to investigate the feasibility, efficacy, and safety of EBV treatment in patients with AAT deficiency (AATD) or a reduced AAT level. Method: A retrospective analysis was performed of all patients treated with EBV with confirmed AATD or with a reduced AAT serum level at the University Medical Center Groningen between 2013 and 2021. Baseline and 6-month follow-up assessment included chest CT, pulmonary function measurement, 6-min walking distance (6MWD), and St. George’s Respiratory Questionnaire (SGRQ). Results: In total, 53 patients were included, 30 patients in the AATD group (AAT <0.6 g/L or confirmed ZZ phenotype) and 23 patients in the reduced AAT group (AAT 0.6–1 g/L). In both groups, all response variables improved significantly after treatment. There was a median increase in forced expiratory volume in 1 s of 105 mL (12% relative) and 280 mL (31% relative) in the AATD and reduced AAT groups, respectively. 6MWD increased by 62 min and 52 min, and SGRQ decreased by 12.5 patients and 18.7 patients, respectively. A pneumothorax occurred in 10% and 13% of patients, and no patients died. Conclusions: EBV treatment in patients with emphysema and AATD or a reduced AAT level is feasible and results in significant improvements in pulmonary function, exercise capacity, and quality of life and has an acceptable safety profile.
Background: Bronchoscopic lung volume reduction using the Zephyr® endobronchial valve (EBV) is a guideline treatment for patients with advanced emphysema. To achieve volume reduction, it is crucial that there is absence of collateral ventilation and a complete occlusion of the target lobe. While 3 EBV sizes (4.0; 4.0-LP; and 5.5) are currently available to accommodate all airway sizes, local anatomical variations sometimes warrant a valve with a wide diameter but shorter length. To address this, a new “low profile” 5.5-LP EBV has been introduced. Objective: In this study, we evaluated the feasibility, safety, and efficacy of this new 5.5-LP EBV. Methods: This was a single-center, prospective, open-label study. Patients were included if eligible for valve treatment with a local anatomy suitable to place at least one 5.5-LP EBV. Feasibility of placement of the 5.5-LP EBV was reported. Safety, CT parameters, pulmonary function tests, and St. George’s Respiratory Questionnaire (SGRQ) were assessed at baseline and 6 weeks after treatment. Results: We included 30 patients with severe chronic obstructive pulmonary disease (forced expiratory volume in 1 s [FEV1] 29 ± 10%; [RV] 242 ± 46%; and SGRQ 56 ± 11 points). Besides the regular EBV sizes, a median of 1 (1–3) of the new 5.5-LP EBV was placed. No valve adjustment was needed during the initial procedure. A single asymptomatic small pneumothorax was observed in 1 patient. In 4 patients, a revision bronchoscopy was performed due to absence of clinical benefit. In 1 patient, this was related to a dislocation of the 5.5-LP EBV. Clinically relevant improvements were seen in target lobar volume reduction (–1,554 mL), FEV1 +39%, RV –960 mL, and SGRQ –18 points. Conclusions: In this first in human study, the 5.5-LP EBV could be placed into wide segments with a shorter landing length without unexpected complications and with good efficacy outcomes.